Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/41 ▾
  1. 1.Department Operations & Safety0/5
    1. The work environment: pressure, humidity, cleaning and workflow
    2. Attire, jewelry and traffic control
    3. Workplace safety: spills, chemicals and safe lifting
    4. Regulators, standards and the order of authority
    5. Training records, documentation and quality improvement tools
  2. 2.Decontamination & Cleaning0/5
    1. Point-of-use treatment and safe transport
    2. The decontamination room and personal protective equipment
    3. Manual cleaning: water, brushes and detergent
    4. Ultrasonic cleaners and washer-disinfectors
    5. Flexible endoscopes and automated reprocessors
  3. 3.Sterilization Methods0/5
    1. How steam kills and how air is removed
    2. The daily air-removal (Bowie-Dick) test
    3. Physical, chemical and biological monitoring
    4. Release decisions: requalification, implants and immediate use
    5. Loading, wet packs, cooling and low-temperature methods
  4. 4.Packaging & Sterile Storage0/4
    1. Inspecting and assembling instruments
    2. Wraps and wrapping techniques
    3. Peel pouches, rigid containers and labels
    4. Cooling, wet packs and sterile storage
  5. 5.Quality Assurance & Monitoring0/5
    1. Sterilizer records, lot control and traceability
    2. Releasing a load and handling implants
    3. Positive biological indicators, recalls and failure reports
    4. Shelf life, stock rotation and package inspection
    5. Instructions for use, loaners, competency and quality benchmarks
  6. 6.Infection Prevention0/5
    1. The chain of infection, Standard Precautions and hand hygiene
    2. Decontamination design, airflow and safe transport
    3. Sharps, PPE and exposure incidents
    4. The Spaulding classification and high-level disinfection
    5. Microbial resistance, soil, biofilm and prions
  7. 7.Storage, Inventory & Distribution0/4
    1. Replenishment systems and ordering
    2. Receiving in the break-out area
    3. Sterile storage, rotation and transport
    4. Tracking, recalls and inventory problems
  8. 8.Patient Care Equipment0/4
    1. Why patient care equipment is noncritical
    2. Cleaning, contact time and a clean work area
    3. Inspection and removal from service
    4. Preparing, storing, distributing and tracking
  9. 9.Professional Skills & Terminology0/4
    1. Procedure suffixes: what the surgeon will do
    2. Body-part roots and putting words together
    3. Protecting patient information under HIPAA
    4. Professional communication and teamwork
Saved in this browser. Move it to another device →
← Decontamination & Cleaning

Chapter 2 · Lesson 4 of 5

Ultrasonic cleaners and washer-disinfectors

1 min read

An ultrasonic cleaner works by cavitation. High-frequency sound waves create tiny bubbles that collapse violently against the instrument and pull fine soil out of box locks and serrations that a brush cannot reach.

It cleans only; it has no antimicrobial claim. Gross soil comes off first, items are fully submerged with hinges open, the lid stays closed to contain aerosols, and items are rinsed afterward.

Fresh solution must be degassed, because dissolved air cushions the bubbles and weakens cavitation. Stainless steel is not mixed with chrome-plated, brass, aluminum or copper items, because dissimilar metals in an electrolyte set up galvanic action that pits the metal.

A washer-disinfector cleans by spray impingement, so it cleans only where water strikes the surface. Load it with hinges open, concave items on edge, heavy items on the bottom, lumens attached to manifolds, and no stacking or overloading. Both machines need low-foaming detergent, because foam absorbs the spray and cavitation energy before it reaches the instrument.

Example: a washer is used Monday through Friday and gets a major repair on Wednesday afternoon.

It is tested with a cleaning verification device each of those 5 days, plus once more after the repair before loads go back in. If any test fails, the machine comes out of service, affected loads are held or reprocessed, and the cause is investigated and documented.

Check yourself

1. Freshly prepared solution in an ultrasonic cleaner must be degassed before instruments are processed. Why?

2. How does an ultrasonic cleaner remove soil, and what does the process actually accomplish?

Facts checked 2026-11-15 · Sources: HSPA: Certified Registered Central Service Technician (CRCST) exam content outline, CDC/HICPAC: Guideline for Disinfection and Sterilization in Healthcare Facilities, OSHA 29 CFR 1910.1030: Bloodborne Pathogens

Sterile Processing (CRCST) cheat sheet: every key fact on one page →