Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/41 ▾
  1. 1.Department Operations & Safety0/5
    1. The work environment: pressure, humidity, cleaning and workflow
    2. Attire, jewelry and traffic control
    3. Workplace safety: spills, chemicals and safe lifting
    4. Regulators, standards and the order of authority
    5. Training records, documentation and quality improvement tools
  2. 2.Decontamination & Cleaning0/5
    1. Point-of-use treatment and safe transport
    2. The decontamination room and personal protective equipment
    3. Manual cleaning: water, brushes and detergent
    4. Ultrasonic cleaners and washer-disinfectors
    5. Flexible endoscopes and automated reprocessors
  3. 3.Sterilization Methods0/5
    1. How steam kills and how air is removed
    2. The daily air-removal (Bowie-Dick) test
    3. Physical, chemical and biological monitoring
    4. Release decisions: requalification, implants and immediate use
    5. Loading, wet packs, cooling and low-temperature methods
  4. 4.Packaging & Sterile Storage0/4
    1. Inspecting and assembling instruments
    2. Wraps and wrapping techniques
    3. Peel pouches, rigid containers and labels
    4. Cooling, wet packs and sterile storage
  5. 5.Quality Assurance & Monitoring0/5
    1. Sterilizer records, lot control and traceability
    2. Releasing a load and handling implants
    3. Positive biological indicators, recalls and failure reports
    4. Shelf life, stock rotation and package inspection
    5. Instructions for use, loaners, competency and quality benchmarks
  6. 6.Infection Prevention0/5
    1. The chain of infection, Standard Precautions and hand hygiene
    2. Decontamination design, airflow and safe transport
    3. Sharps, PPE and exposure incidents
    4. The Spaulding classification and high-level disinfection
    5. Microbial resistance, soil, biofilm and prions
  7. 7.Storage, Inventory & Distribution0/4
    1. Replenishment systems and ordering
    2. Receiving in the break-out area
    3. Sterile storage, rotation and transport
    4. Tracking, recalls and inventory problems
  8. 8.Patient Care Equipment0/4
    1. Why patient care equipment is noncritical
    2. Cleaning, contact time and a clean work area
    3. Inspection and removal from service
    4. Preparing, storing, distributing and tracking
  9. 9.Professional Skills & Terminology0/4
    1. Procedure suffixes: what the surgeon will do
    2. Body-part roots and putting words together
    3. Protecting patient information under HIPAA
    4. Professional communication and teamwork
Saved in this browser. Move it to another device →
← Department Operations & Safety

Chapter 1 · Lesson 4 of 5

Regulators, standards and the order of authority

1 min read

Each agency has its own job, and exam distractors swap them. FDA regulates medical devices, including chemical indicators, which are Class II devices that need a premarket submission before sale.

CMS does not clear devices; it sets Conditions of Participation that a hospital must meet to take part in Medicare and Medicaid, and its surveyors check sterilization practice under the infection prevention condition. OSHA protects workers.

ANSI/AAMI ST79 is a consensus standard, not a federal law. It is the basis for department policy. In a standard, shall means a requirement, should a recommendation, and may a permission. When sources conflict, the Joint Commission hierarchy taught by HSPA ranks them in this order:

  • 1. Laws and regulations
  • 2. CMS requirements
  • 3. Manufacturers' written instructions for use (IFU)
  • 4. Evidence-based guidelines and national standards
  • 5. Consensus documents
  • 6. The organization's own policies

Example: a department procedure disagrees with a device's current IFU. The IFU rank higher, so the procedure is rewritten to match. Under FDA Medical Device Reporting, a facility reports a device-related serious injury to the manufacturer, or to FDA if the manufacturer is unknown; a device-related death goes to both.

Check yourself

1. A department's written procedure for a device says one thing, and the current manufacturer's instructions for use (IFU) for that device say something different. Under the Joint Commission's hierarchy for infection prevention requirements, how do the two rank?

2. A new technician asks how the Centers for Medicare & Medicaid Services (CMS) can hold a hospital's sterile processing department to infection prevention requirements when CMS does not clear any device. What is the basis for that authority?

Facts checked 2026-11-15 · Sources: HSPA: Certified Registered Central Service Technician (CRCST), OSHA 29 CFR 1910.1030: Bloodborne Pathogens, OSHA 29 CFR 1910.1200: Hazard Communication

Sterile Processing (CRCST) cheat sheet: every key fact on one page →