Reading interface counters and port states
1 min read
| What you see | What it means |
|---|---|
| Late collisions and FCS errors on one side, runts and CRC errors on the other; ping fine, big transfers crawl | Duplex mismatch; set both ends to match, ideally both on autonegotiation |
| Rising output drops, zero CRC, runts and giants, utilization near 100% at peak | Egress congestion; add capacity or QoS |
| Rising CRC or FCS errors alone | Corruption on the medium, such as a damaged cable or EMI |
| Port err-disabled | The switch shut it for a violation such as port security, BPDU guard or flapping; remove the cause first |
| Port administratively down | A person shut it down |
| Port suspended | Link-aggregation settings do not match the rest of the bundle |
Runts are frames under the 64-byte minimum and giants are frames over the maximum size, so neither appears when the only problem is a full queue. Drops are counted when a frame arrives for a buffer that is already full.
Check yourself
1. A server connects to a switch over a 40 m certified copper run. Ping between the two succeeds with normal round-trip times, but large file transfers crawl. The switch interface counters show a steadily rising late collision count and FCS errors, while the server NIC counters show runts and CRC errors. What is the most likely cause?
2. A technician reads an interface summary on a building uplink: 'input errors 0, CRC 0, runts 0, giants 0, output drops 184532', and utilization peaks at 98 percent every afternoon while the link stays up. What do these counters prove?