Chapters0/30 ▾
Chapter 1 · Lesson 5 of 5
Topologies and network types: domains, mesh, spine and leaf, SAN
1 min read
A switch gives every port its own collision domain, which is what allows full duplex. A hub repeats everything out every port, so all its stations share one collision domain.
Broadcasts flood every port in a VLAN, so one VLAN is one broadcast domain, and only another VLAN or a router splits it. Example: a 12-port switch with every port used, split into two VLANs, has 12 collision domains and 2 broadcast domains.
A full mesh needs n(n-1)/2 links. Six sites need 6 x 5 / 2 = 15 links, and ten sites already need 45, which is why full mesh is kept for a few critical sites and larger networks use partial mesh or hub-and-spoke.
In a spine and leaf data center, every leaf connects to every spine, spines never connect to each other, and any server-to-server path is leaf, spine, leaf. That equal hop count serves east-west traffic between servers.
Storage has its own terms. A SAN presents raw block-level volumes to servers over a dedicated fabric such as Fibre Channel or an isolated iSCSI network. A NAS owns its file system and shares files over the normal LAN. MAN and PAN describe geographic size, not storage.
Check yourself
1. Eight sites are to be joined in a full mesh, in which every site has a direct link to every other site. How many links are required?
2. A group of servers needs raw block-level storage volumes delivered over a dedicated storage network rather than file shares carried on the production LAN. Which term describes that arrangement?
Facts checked 2026-11-16 · Sources: CompTIA Network+ certification overview, RFC 1122: Requirements for Internet Hosts (TCP/IP layering)
CompTIA Network+ cheat sheet: every key fact on one page →