Chapters0/30 ▾
Chapter 6 · Lesson 2 of 5
Cable faults, distance limits, PoE budgets and the right tester
1 min read
Twisted-pair Ethernet is specified for a 100 m channel, which the cabling standard divides into a 90 m permanent link plus up to 10 m of patch cords. Example: 80 m of horizontal cable plus a 3 m cord at each end is 86 m and fits; 115 m of horizontal cable alone does not.
Beyond the limit, attenuation drops the signal below the receiver's threshold, so the link becomes intermittent and error-prone under load rather than dead.
A split pair keeps continuity pin for pin, so a basic DC continuity tester calls it good. But the two wires of a signal come from different twisted pairs, the twist no longer cancels noise, and near-end crosstalk climbs at gigabit frequencies.
The link may settle at 100 Mbps or throw CRC errors at 1 Gbps. A certification tester, which measures crosstalk and other performance values, confirms it.
Power has its own limit. A PoE switch has a total wattage budget, so when cameras keep being added, the last ones fail to power on or reboot in a loop even though their cabling tests clean and they work on another switch. Check the switch's power status, not its VLANs or routes.
Check yourself
1. A new 1000BASE-T drop links intermittently and shows errors under load. The installer measured the horizontal cable run at 115 m from the patch panel to the wall jack, with a 3 m patch cord at each end; the cable is Category 6 and both terminations are correct. What is the best explanation?
2. A newly terminated Category 6 drop passes a basic DC continuity test with all eight conductors mapped straight through, pin for pin, and no opens or shorts. Yet the link only negotiates 100 Mbps, and when forced to 1 Gbps it produces continuous CRC errors. What is the most likely fault and which tool confirms it?
Facts checked 2026-11-16 · Sources: CompTIA Network+ certification overview, RFC 3927: Dynamic Configuration of IPv4 Link-Local Addresses