Chapters0/30 ▾
Chapter 4 · Lesson 4 of 5
Disaster recovery and high availability
1 min read
| Term | Meaning |
|---|---|
| RPO | Most data you may lose, measured back from the incident; sets backup frequency |
| RTO | Longest the service may stay down; improved by faster restore or standby gear |
| MTBF | Average operating time between failures (reliability) |
| MTTR | Average time to repair a failed device (maintainability) |
Availability equals MTBF divided by MTBF plus MTTR.
Example: MTBF of 2,000 hours and MTTR of 4 hours give 2,000 / 2,004, about 99.80%. Recovery sites trade cost for speed: a cold site is space, power and connectivity and takes days; a warm site has hardware and software installed and recovers in hours; a hot site is fastest and costs the most.
Active-active clusters share the load and must synchronize state, so each node must be able to carry the whole load; active-passive keeps an idle standby. A tabletop exercise only talks through the plan, so only a real restore or failover test proves the RPO and RTO. Hot and cold aisles keep exhaust air out of equipment intakes.
Check yourself
1. A business states that a failure of the order-processing system must never cost more than 15 minutes of transactions. Which recovery metric is being defined, and what does it primarily dictate?
2. Which metric is the average elapsed time required to restore a failed but repairable device to service, making it a measure of maintainability rather than of how often failures occur?
Facts checked 2026-11-16 · Sources: CompTIA Network+ certification overview, RFC 5424: The Syslog Protocol, NIST SP 800-34 Rev. 1: Contingency Planning Guide for Federal Information Systems
CompTIA Network+ cheat sheet: every key fact on one page →