1 min read

Two gauges tell most of the story. The vacuum gauge on the suction side climbs when something restricts the water reaching the pump, such as a leaf-packed strainer basket or a plugged skimmer.

The pressure gauge on the filter climbs as the media loads with dirt. Each fault has its own signature, and the exam tests whether you can tell them apart instead of backwashing by reflex.

ReadingsLikely cause
Vacuum high, filter pressure low, flow downSuction blockage: strainer, skimmer or drain
Filter pressure well above the clean reading, vacuum normalLoaded filter that needs cleaning

Always log the pressure right after cleaning. Clean pressure differs from system to system, so only the rise above that baseline shows how loaded the filter is. Example: a filter that read 12 psi clean and now reads 22 psi has risen 10 psi; compare that rise with the manufacturer's cleaning point.

A flow meter needs a straight run of pipe ahead of it, because turbulence just after an elbow gives erratic, low readings.

Check yourself

1. The filter pressure gauge reads lower than usual, the pump strainer vacuum gauge reads high, and flow is down. What does this pattern point to?

2. During a weekly inspection the operator finds the hair-and-lint strainer basket packed with leaves. What is the immediate hydraulic consequence if it is left that way?

Facts checked 2026-11-15 · Sources: PHTA: Certified Pool/Spa Operator (CPO) certification, CDC: Model Aquatic Health Code, 5th edition (2024)

Pool Operator (CPO) cheat sheet: every key fact on one page →