Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
← Pool Math & Calculations

Chapter 4 · Lesson 5 of 5

Dilution, heating and spa water replacement

1 min read

Draining and refilling is how you lower cyanuric acid and dissolved solids. If the fill water contains none of the substance, the new level is simply the old level times the fraction kept.

Example: cyanuric acid at 120 ppm, drain 30 percent, refill with water that has none: 120 x 0.70 = 84 ppm. If the fill water does carry some, blend the two. Example: dissolved solids at 2,400 ppm, drain one third, refill with 300 ppm water: (2/3 x 2,400) + (1/3 x 300) = 1,600 + 100 = 1,700 ppm.

Heating uses the BTU: one BTU raises one pound of water by one degree F, and a gallon weighs 8.33 pounds. Multiply gallons x 8.33 x the temperature rise. Example: 15,000 gallons from 70 to 80 degrees F is 15,000 x 8.33 x 10 = 1,249,500 BTU.

The operator handbook gives a spa water replacement interval of spa gallons divided by 3, then divided by average daily users. Example: a 1,200-gallon spa with 16 users a day gives 1,200 / 3 = 400, and 400 / 16 = 25 days.

Your health code may set its own rule. Common slips are skipping the divide-by-3 step or multiplying by 3, and forgetting the 8.33 pounds per gallon in heating problems.

Check yourself

1. A pool measures 2,800 ppm total dissolved solids. The operator drains one quarter of the water and refills with fill water measuring 200 ppm total dissolved solids. What is the resulting level after mixing?

2. A 20,000-gallon pool must be heated from 68 degrees F to 82 degrees F. Using 8.33 pounds per gallon and the rule that one BTU raises one pound of water one degree F, how many BTUs are required?

Facts checked 2026-11-15 · Sources: PHTA: Certified Pool/Spa Operator (CPO) certification, CDC: Model Aquatic Health Code, 5th edition (2024)

Pool Operator (CPO) cheat sheet: every key fact on one page →