Chapters0/38 ▾
- 1.Safety, PPE, SCBA & Communications0/5
- 2.Fire Behavior & Building Construction0/5
- 3.Ground Ladders & Forcible Entry0/4
- 4.Search & Rescue and Ventilation0/4
- 5.Water Supply, Hose, Streams & Extinguishers0/5
- 6.Fire Control, Overhaul, Ropes & Knots0/5
- 7.Firefighter II Operations0/5
- 8.Hazmat Awareness & Operations0/5
Study guide · Chapter 1 of 8
Safety, PPE, SCBA & Communications Study Guide — Firefighter I & II Certification
Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.
22 free practice questions
This section covers the rules that keep firefighters alive on the fireground: two-in/two-out, accountability, maydays and radio use, turnout gear care, SCBA and the PASS device. Each state or accredited agency writes and scores its own Firefighter I/II exam, but all of them test these skills from the same national standard, NFPA 1010. Most questions describe a short scene and ask for the safe action or the right rule.
Key takeaways
- For an interior attack in an IDLH atmosphere, at least two firefighters go in together and at least two equipped firefighters stay outside ready to rescue, unless a life is in imminent danger.
- Call a mayday the moment you are lost, trapped or in trouble, then give location, unit, name, air and needs.
- Structural turnout gear is retired no more than 10 years after manufacture, no matter how it looks, and gets an advanced inspection at least every 12 months.
- Under the Rule of Air Management you leave the hazard area before the low-air alarm sounds, so the alarm is a backup, not the signal to start out.
- A PASS goes into alarm when the wearer stops moving; integrated units arm when the cylinder is opened, stand-alone units must be switched on by hand.
Lessons in this chapter
5 short lessons · 5 min read
- 1Two-in/two-out and personnel accountability1 min
- 2Maydays, emergency traffic and radio discipline1 min
- 3Turnout gear: layers, inspection, retirement and decon1 min
- 4SCBA readiness, air management and emergencies1 min
- 5PASS devices and roadway scene safety1 min
Facts checked 2026-11-15 · Sources: OSHA 29 CFR 1910.134: Respiratory Protection (two-in/two-out, paragraph (g)(4)), NFPA 1010: Professional Qualifications for Firefighters, NFPA 1850: Selection, Care and Maintenance of Protective Ensembles
Firefighter I & II Certification cheat sheet: every key fact on one page →Next chapter: Fire Behavior & Building Construction →Original practice questions written to the job performance requirements of NFPA 1010 (2024), which replaced NFPA 1001 for Fire Fighter I and II, and NFPA 470 for hazardous materials Awareness and Operations. Not affiliated with or endorsed by NFPA, IFSAC, the Pro Board, or any state fire academy. Each state writes its own certification exam — check your state's fire academy or certification office for its format and which edition it tests. NFPA 1010 standard →