Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/38 ▾
  1. 1.Safety, PPE, SCBA & Communications0/5
    1. Two-in/two-out and personnel accountability
    2. Maydays, emergency traffic and radio discipline
    3. Turnout gear: layers, inspection, retirement and decon
    4. SCBA readiness, air management and emergencies
    5. PASS devices and roadway scene safety
  2. 2.Fire Behavior & Building Construction0/5
    1. The fire tetrahedron, fuel properties and toxic smoke
    2. Heat transfer and reading smoke
    3. Ventilation-limited fires and hostile fire events
    4. Flow paths, closed doors and applying water
    5. Construction types and collapse hazards
  3. 3.Ground Ladders & Forcible Entry0/4
    1. Ladder parts, materials and service testing
    2. Climbing angle, tip placement and power lines
    3. Forcible entry tools and their care
    4. Forcing doors, locks, glass and roll-up gates
  4. 4.Search & Rescue and Ventilation0/4
    1. Primary and secondary search
    2. Moving victims, downed firefighters and VEIS
    3. Flow paths, door control and timing ventilation
    4. Horizontal, PPV, hydraulic and vertical ventilation
  5. 5.Water Supply, Hose, Streams & Extinguishers0/5
    1. Hydrants, water pressure and drafting
    2. Supply hose lays, hose loads and appliances
    3. Hose couplings, rolls and hose care
    4. Fire streams: nozzle pressure, steam and friction loss
    5. Portable extinguishers: classes, ratings and PASS
  6. 6.Fire Control, Overhaul, Ropes & Knots0/5
    1. Life safety rope, utility rope and rope care
    2. Knots and hoisting tools and hoselines
    3. Interior fire attack: direct, indirect and below-grade fires
    4. Vehicle, grass and flammable gas fires
    5. Property conservation and overhaul
  7. 7.Firefighter II Operations0/5
    1. Command and the Incident Command System
    2. Foam, flammable liquids and BLEVE prevention
    3. Sprinklers, standpipes and smoke alarms
    4. Fire cause, evidence and incident reports
    5. Airbag clearance, thermal imaging and hose testing
  8. 8.Hazmat Awareness & Operations0/5
    1. Response levels, training and a safe approach
    2. Placards, NFPA 704 and container shapes
    3. Using the Emergency Response Guidebook
    4. Product behavior, defensive control and public protection
    5. Control zones, decontamination and protection levels
Saved in this browser. Move it to another device →
← Back

Study guide · Chapter 2 of 8

Fire Behavior & Building Construction Study Guide — Firefighter I & II Certification

Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.

22 free practice questions

This section asks how fire starts, grows and spreads, how to read smoke and spot hostile fire events, and how different buildings behave once they burn. Each state or accredited agency writes its own Firefighter I/II exam, but all of them test this NFPA 1010 knowledge, and many questions now reflect UL FSRI research on modern fires. Expect short scenes where you name the event, the heat transfer method or the construction type.

Key takeaways

  • Water mainly cools, smothering removes oxygen, fuel removal separates fuel, and dry chemical mainly breaks the chemical chain reaction.
  • A closed-up fire that looks like it is dying is usually ventilation-limited, and any new opening, even the entry door, can make it grow fast.
  • Backdraft needs air added to a hot, sealed, fuel-rich space; a smoke explosion is premixed smoke igniting, often in a void after knockdown.
  • UL FSRI found that water applied into the fire area did not push fire into other rooms, and that a closed door keeps a room survivable much longer.
  • Set a collapse zone of at least 1.5 times the wall height, and expect fast, unannounced failure from lightweight trusses and unprotected steel.

Lessons in this chapter

5 short lessons · 5 min read

  1. 1The fire tetrahedron, fuel properties and toxic smoke1 min
  2. 2Heat transfer and reading smoke1 min
  3. 3Ventilation-limited fires and hostile fire events1 min
  4. 4Flow paths, closed doors and applying water1 min
  5. 5Construction types and collapse hazards1 min
View all questions & answers →

Facts checked 2026-11-15 · Sources: NFPA 1010: Professional Qualifications for Firefighters, UL FSRI: Impact of Fire Attack Utilizing Interior and Exterior Streams, NFPA 220: Standard on Types of Building Construction

Firefighter I & II Certification cheat sheet: every key fact on one page →Next chapter: Ground Ladders & Forcible Entry →

Original practice questions written to the job performance requirements of NFPA 1010 (2024), which replaced NFPA 1001 for Fire Fighter I and II, and NFPA 470 for hazardous materials Awareness and Operations. Not affiliated with or endorsed by NFPA, IFSAC, the Pro Board, or any state fire academy. Each state writes its own certification exam — check your state's fire academy or certification office for its format and which edition it tests. NFPA 1010 standard →