Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/38 ▾
  1. 1.Safety, PPE, SCBA & Communications0/5
    1. Two-in/two-out and personnel accountability
    2. Maydays, emergency traffic and radio discipline
    3. Turnout gear: layers, inspection, retirement and decon
    4. SCBA readiness, air management and emergencies
    5. PASS devices and roadway scene safety
  2. 2.Fire Behavior & Building Construction0/5
    1. The fire tetrahedron, fuel properties and toxic smoke
    2. Heat transfer and reading smoke
    3. Ventilation-limited fires and hostile fire events
    4. Flow paths, closed doors and applying water
    5. Construction types and collapse hazards
  3. 3.Ground Ladders & Forcible Entry0/4
    1. Ladder parts, materials and service testing
    2. Climbing angle, tip placement and power lines
    3. Forcible entry tools and their care
    4. Forcing doors, locks, glass and roll-up gates
  4. 4.Search & Rescue and Ventilation0/4
    1. Primary and secondary search
    2. Moving victims, downed firefighters and VEIS
    3. Flow paths, door control and timing ventilation
    4. Horizontal, PPV, hydraulic and vertical ventilation
  5. 5.Water Supply, Hose, Streams & Extinguishers0/5
    1. Hydrants, water pressure and drafting
    2. Supply hose lays, hose loads and appliances
    3. Hose couplings, rolls and hose care
    4. Fire streams: nozzle pressure, steam and friction loss
    5. Portable extinguishers: classes, ratings and PASS
  6. 6.Fire Control, Overhaul, Ropes & Knots0/5
    1. Life safety rope, utility rope and rope care
    2. Knots and hoisting tools and hoselines
    3. Interior fire attack: direct, indirect and below-grade fires
    4. Vehicle, grass and flammable gas fires
    5. Property conservation and overhaul
  7. 7.Firefighter II Operations0/5
    1. Command and the Incident Command System
    2. Foam, flammable liquids and BLEVE prevention
    3. Sprinklers, standpipes and smoke alarms
    4. Fire cause, evidence and incident reports
    5. Airbag clearance, thermal imaging and hose testing
  8. 8.Hazmat Awareness & Operations0/5
    1. Response levels, training and a safe approach
    2. Placards, NFPA 704 and container shapes
    3. Using the Emergency Response Guidebook
    4. Product behavior, defensive control and public protection
    5. Control zones, decontamination and protection levels
Saved in this browser. Move it to another device →
← Safety, PPE, SCBA & Communications

Chapter 1 · Lesson 5 of 5

PASS devices and roadway scene safety

Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.

1 min read

A PASS (personal alert safety system) has a motion sensor. If the wearer stays still for a set time it sounds a pre-alarm, and if there is still no movement it goes into full alarm so crews can find a downed firefighter.

It can also be set off by hand. It does not react to low cylinder pressure, heart rate or radio contact; low air is signaled by the end-of-service-time indicator. The PASS requirements once in NFPA 1982 are now part of NFPA 1970.

Arming is a common test point. An integrated PASS is built into the SCBA and arms itself when the cylinder valve is opened. A stand-alone PASS must be switched on by the firefighter, a step often missed while donning.

Example: a recruit opens the cylinder on a pack with a clip-on PASS and assumes it is armed. It is not, until the recruit turns it on.

Roadway incidents are a separate danger. The first-arriving apparatus is placed upstream of the crash, between oncoming traffic and the work area, and angled to block lanes, so a car that fails to stop hits the truck instead of a firefighter.

Parking past the crash or right beside it leaves the crew in the traffic stream. The federal MUTCD Part 6 covers traffic incident management areas.

Check yourself

1. A firefighter's PASS (personal alert safety system) device sounds a pre-alarm and then a full alarm without anyone pressing a button. What triggers this automatic alarm?

2. Which statement about arming a PASS (personal alert safety system) device is correct?

Facts checked 2026-11-15 · Sources: OSHA 29 CFR 1910.134: Respiratory Protection (two-in/two-out, paragraph (g)(4)), NFPA 1010: Professional Qualifications for Firefighters, NFPA 1850: Selection, Care and Maintenance of Protective Ensembles

Firefighter I & II Certification cheat sheet: every key fact on one page →