Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/38 ▾
  1. 1.Safety, PPE, SCBA & Communications0/5
    1. Two-in/two-out and personnel accountability
    2. Maydays, emergency traffic and radio discipline
    3. Turnout gear: layers, inspection, retirement and decon
    4. SCBA readiness, air management and emergencies
    5. PASS devices and roadway scene safety
  2. 2.Fire Behavior & Building Construction0/5
    1. The fire tetrahedron, fuel properties and toxic smoke
    2. Heat transfer and reading smoke
    3. Ventilation-limited fires and hostile fire events
    4. Flow paths, closed doors and applying water
    5. Construction types and collapse hazards
  3. 3.Ground Ladders & Forcible Entry0/4
    1. Ladder parts, materials and service testing
    2. Climbing angle, tip placement and power lines
    3. Forcible entry tools and their care
    4. Forcing doors, locks, glass and roll-up gates
  4. 4.Search & Rescue and Ventilation0/4
    1. Primary and secondary search
    2. Moving victims, downed firefighters and VEIS
    3. Flow paths, door control and timing ventilation
    4. Horizontal, PPV, hydraulic and vertical ventilation
  5. 5.Water Supply, Hose, Streams & Extinguishers0/5
    1. Hydrants, water pressure and drafting
    2. Supply hose lays, hose loads and appliances
    3. Hose couplings, rolls and hose care
    4. Fire streams: nozzle pressure, steam and friction loss
    5. Portable extinguishers: classes, ratings and PASS
  6. 6.Fire Control, Overhaul, Ropes & Knots0/5
    1. Life safety rope, utility rope and rope care
    2. Knots and hoisting tools and hoselines
    3. Interior fire attack: direct, indirect and below-grade fires
    4. Vehicle, grass and flammable gas fires
    5. Property conservation and overhaul
  7. 7.Firefighter II Operations0/5
    1. Command and the Incident Command System
    2. Foam, flammable liquids and BLEVE prevention
    3. Sprinklers, standpipes and smoke alarms
    4. Fire cause, evidence and incident reports
    5. Airbag clearance, thermal imaging and hose testing
  8. 8.Hazmat Awareness & Operations0/5
    1. Response levels, training and a safe approach
    2. Placards, NFPA 704 and container shapes
    3. Using the Emergency Response Guidebook
    4. Product behavior, defensive control and public protection
    5. Control zones, decontamination and protection levels
Saved in this browser. Move it to another device →
← Safety, PPE, SCBA & Communications

Chapter 1 · Lesson 3 of 5

Turnout gear: layers, inspection, retirement and decon

Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.

1 min read

A structural firefighting coat and pants have three layers. From the outside in they are the outer shell, which resists flame, cuts and abrasion; the moisture barrier, which blocks water, steam and many liquids; and the thermal liner next to the body, which gives most of the insulation.

Reflective shells belong to proximity gear, not structural gear. The design and certification standard is now NFPA 1970 (2025), which absorbed NFPA 1971.

Care step (NFPA 1850)When
Routine inspectionAfter every use
Advanced inspection by a trained personAt least every 12 months, or whenever damage is suspected
RetirementNo more than 10 years after the date of manufacture

Example: a coat made in March 2015 looks almost new in November 2026. It is over 11 years old, so it is retired. Passing an inspection, an advanced cleaning, or moving it to training does not reset the 10-year limit.

To cut carcinogen exposure, crews do gross decon on scene: brush and rinse the gear, ideally while still on air, then bag it and keep it out of the crew cab.

Check yourself

1. During a routine inspection, a firefighter finds that their turnout coat is in good condition but was manufactured 11 years ago. What should happen to the coat?

2. Listed from the outside in, which three layers make up a structural firefighting coat?

Facts checked 2026-11-15 · Sources: OSHA 29 CFR 1910.134: Respiratory Protection (two-in/two-out, paragraph (g)(4)), NFPA 1010: Professional Qualifications for Firefighters, NFPA 1850: Selection, Care and Maintenance of Protective Ensembles

Firefighter I & II Certification cheat sheet: every key fact on one page →