Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/38 ▾
  1. 1.Safety, PPE, SCBA & Communications0/5
    1. Two-in/two-out and personnel accountability
    2. Maydays, emergency traffic and radio discipline
    3. Turnout gear: layers, inspection, retirement and decon
    4. SCBA readiness, air management and emergencies
    5. PASS devices and roadway scene safety
  2. 2.Fire Behavior & Building Construction0/5
    1. The fire tetrahedron, fuel properties and toxic smoke
    2. Heat transfer and reading smoke
    3. Ventilation-limited fires and hostile fire events
    4. Flow paths, closed doors and applying water
    5. Construction types and collapse hazards
  3. 3.Ground Ladders & Forcible Entry0/4
    1. Ladder parts, materials and service testing
    2. Climbing angle, tip placement and power lines
    3. Forcible entry tools and their care
    4. Forcing doors, locks, glass and roll-up gates
  4. 4.Search & Rescue and Ventilation0/4
    1. Primary and secondary search
    2. Moving victims, downed firefighters and VEIS
    3. Flow paths, door control and timing ventilation
    4. Horizontal, PPV, hydraulic and vertical ventilation
  5. 5.Water Supply, Hose, Streams & Extinguishers0/5
    1. Hydrants, water pressure and drafting
    2. Supply hose lays, hose loads and appliances
    3. Hose couplings, rolls and hose care
    4. Fire streams: nozzle pressure, steam and friction loss
    5. Portable extinguishers: classes, ratings and PASS
  6. 6.Fire Control, Overhaul, Ropes & Knots0/5
    1. Life safety rope, utility rope and rope care
    2. Knots and hoisting tools and hoselines
    3. Interior fire attack: direct, indirect and below-grade fires
    4. Vehicle, grass and flammable gas fires
    5. Property conservation and overhaul
  7. 7.Firefighter II Operations0/5
    1. Command and the Incident Command System
    2. Foam, flammable liquids and BLEVE prevention
    3. Sprinklers, standpipes and smoke alarms
    4. Fire cause, evidence and incident reports
    5. Airbag clearance, thermal imaging and hose testing
  8. 8.Hazmat Awareness & Operations0/5
    1. Response levels, training and a safe approach
    2. Placards, NFPA 704 and container shapes
    3. Using the Emergency Response Guidebook
    4. Product behavior, defensive control and public protection
    5. Control zones, decontamination and protection levels
Saved in this browser. Move it to another device →
← Back

Study guide · Chapter 7 of 8

Firefighter II Operations Study Guide — Firefighter I & II Certification

Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.

24 free practice questions

Fire Fighter II adds the skills of a firefighter who can run a small incident and work with less supervision: command and the Incident Command System, foam and flammable-liquid fires, fire protection systems, fire cause and reporting, and vehicle extrication. Questions often ask which ICS term, system type or foam method fits a scene. Each state or accredited agency writes its own exam, and IFSAC or Pro Board accreditation can help a certificate be recognized in other states, though each state sets its own reciprocity rules.

Key takeaways

  • Command transfers only by a deliberate, preferably face-to-face briefing, never automatically when a higher rank arrives.
  • ICS span of control is 3 to 7 per supervisor with 5 as the optimum; divisions are geographic and groups are functional.
  • A foam percentage is the share of concentrate in the solution, and polar solvents such as ethanol need alcohol-resistant concentrate.
  • On an OS&Y valve a visible, extended stem means open, and a Class I standpipe gives the fire department 2½-inch outlets.
  • Firefighters recognize and protect possible evidence and report it, while the investigator documents, collects and decides the cause.

Lessons in this chapter

5 short lessons · 5 min read

  1. 1Command and the Incident Command System1 min
  2. 2Foam, flammable liquids and BLEVE prevention1 min
  3. 3Sprinklers, standpipes and smoke alarms1 min
  4. 4Fire cause, evidence and incident reports1 min
  5. 5Airbag clearance, thermal imaging and hose testing1 min
View all questions & answers →

Facts checked 2026-11-15 · Sources: NFPA 1010 (2024): Professional Qualifications for Firefighters, FEMA: National Incident Management System (NIMS) doctrine, NFPA 11: Low-, Medium-, and High-Expansion Foam

Firefighter I & II Certification cheat sheet: every key fact on one page →Next chapter: Hazmat Awareness & Operations →

Original practice questions written to the job performance requirements of NFPA 1010 (2024), which replaced NFPA 1001 for Fire Fighter I and II, and NFPA 470 for hazardous materials Awareness and Operations. Not affiliated with or endorsed by NFPA, IFSAC, the Pro Board, or any state fire academy. Each state writes its own certification exam — check your state's fire academy or certification office for its format and which edition it tests. NFPA 1010 standard →