Chapters0/38 ▾
- 1.Safety, PPE, SCBA & Communications0/5
- 2.Fire Behavior & Building Construction0/5
- 3.Ground Ladders & Forcible Entry0/4
- 4.Search & Rescue and Ventilation0/4
- 5.Water Supply, Hose, Streams & Extinguishers0/5
- 6.Fire Control, Overhaul, Ropes & Knots0/5
- 7.Firefighter II Operations0/5
- 8.Hazmat Awareness & Operations0/5
Chapter 3 · Lesson 1 of 4
Ladder parts, materials and service testing
Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.
1 min read
An extension ladder has a bed section and one or more fly sections. The halyard raises and lowers the fly, the guides keep the sections aligned as they slide, the stops keep the fly from coming out past full extension, and the pawls (also called dogs or ladder locks) hook over a bed-section rung to hold the fly at height.
Before anyone climbs, confirm the pawls are seated, the halyard is tied off, and the butt spurs are on the ground. Fly-in or fly-out orientation follows the manufacturer's recommendation, since ladders are designed and tested one way.
Ladder care and service testing is now in NFPA 1930 (2025), which absorbed the old NFPA 1932. In-service ladders are service tested at least once a year. Extra tests are required before reuse after direct flame or high heat, overloading, damage or repair.
A heat-sensor label near the tip changes color at roughly 300°F (149°C); once it changes, the ladder comes out of service until it passes a service test, even if it looks fine. Washing with mild soap and water or moving it to another rig does not trigger a test.
- Fiberglass is nonconductive only when clean and dry; wet or dirty fiberglass can carry current, and sunlight (UV) degrades it.
- Wood ladders get a clear finish such as varnish, never paint beyond small ID marks at the ends, because paint hides cracks and rot.
Check yourself
1. During a post-fire check, a firefighter sees that the heat-sensor label on the inside of a beam near the tip of a ladder has changed color. What should be done with the ladder?
2. A firefighter extends the fly section of an extension ladder and lets it settle. Which component engages a bed-section rung to hold the fly at that height?
Facts checked 2026-11-15 · Sources: NFPA 1010: Professional Qualifications for Firefighters, NFPA 1930 (2025): care and service testing of ground ladders and fire hose (absorbed NFPA 1932 and 1962)
Firefighter I & II Certification cheat sheet: every key fact on one page →