Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/38 ▾
  1. 1.Safety, PPE, SCBA & Communications0/5
    1. Two-in/two-out and personnel accountability
    2. Maydays, emergency traffic and radio discipline
    3. Turnout gear: layers, inspection, retirement and decon
    4. SCBA readiness, air management and emergencies
    5. PASS devices and roadway scene safety
  2. 2.Fire Behavior & Building Construction0/5
    1. The fire tetrahedron, fuel properties and toxic smoke
    2. Heat transfer and reading smoke
    3. Ventilation-limited fires and hostile fire events
    4. Flow paths, closed doors and applying water
    5. Construction types and collapse hazards
  3. 3.Ground Ladders & Forcible Entry0/4
    1. Ladder parts, materials and service testing
    2. Climbing angle, tip placement and power lines
    3. Forcible entry tools and their care
    4. Forcing doors, locks, glass and roll-up gates
  4. 4.Search & Rescue and Ventilation0/4
    1. Primary and secondary search
    2. Moving victims, downed firefighters and VEIS
    3. Flow paths, door control and timing ventilation
    4. Horizontal, PPV, hydraulic and vertical ventilation
  5. 5.Water Supply, Hose, Streams & Extinguishers0/5
    1. Hydrants, water pressure and drafting
    2. Supply hose lays, hose loads and appliances
    3. Hose couplings, rolls and hose care
    4. Fire streams: nozzle pressure, steam and friction loss
    5. Portable extinguishers: classes, ratings and PASS
  6. 6.Fire Control, Overhaul, Ropes & Knots0/5
    1. Life safety rope, utility rope and rope care
    2. Knots and hoisting tools and hoselines
    3. Interior fire attack: direct, indirect and below-grade fires
    4. Vehicle, grass and flammable gas fires
    5. Property conservation and overhaul
  7. 7.Firefighter II Operations0/5
    1. Command and the Incident Command System
    2. Foam, flammable liquids and BLEVE prevention
    3. Sprinklers, standpipes and smoke alarms
    4. Fire cause, evidence and incident reports
    5. Airbag clearance, thermal imaging and hose testing
  8. 8.Hazmat Awareness & Operations0/5
    1. Response levels, training and a safe approach
    2. Placards, NFPA 704 and container shapes
    3. Using the Emergency Response Guidebook
    4. Product behavior, defensive control and public protection
    5. Control zones, decontamination and protection levels
Saved in this browser. Move it to another device →
← Safety, PPE, SCBA & Communications

Chapter 1 · Lesson 1 of 5

Two-in/two-out and personnel accountability

Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.

1 min read

OSHA's respiratory protection standard, 29 CFR 1910.134(g)(4), sets the minimum team for interior structural firefighting in an IDLH (immediately dangerous to life or health) atmosphere. At least two firefighters enter together and stay in visual or voice contact.

At least two more stay outside, fully equipped and ready to go in for a rescue. That makes four people as the minimum, which is why exam distractors like to offer four as the number outside.

  • One of the two outside members may also serve as incident commander or safety officer, as long as that job does not stop them from performing a rescue.
  • The outside pair cannot leave or join the interior attack while the crew is inside; standing by is their whole job.
  • The exception: if a person is in imminent, life-threatening danger, a crew may act before the full team is assembled.

Accountability continues once crews are inside. A PAR (personnel accountability report) is a roll call: each company officer confirms that every assigned member is present. Command asks for one at set intervals, after an evacuation, or after a mayday.

Example: Command calls for a PAR after a partial roof collapse. The Ladder 3 officer sees all four members and answers that Ladder 3 has a PAR of four. A PAR says nothing about air refills, finished tasks or a rapid intervention crew.

Check yourself

1. Two firefighters are about to enter a burning house for an interior attack in an IDLH atmosphere. Under OSHA's respiratory protection standard, how many properly equipped firefighters must remain outside, ready to rescue them?

2. Midway through an interior operation, the incident commander requests a PAR (personnel accountability report) from all crews. What is each company officer confirming?

Facts checked 2026-11-15 · Sources: OSHA 29 CFR 1910.134: Respiratory Protection (two-in/two-out, paragraph (g)(4)), NFPA 1010: Professional Qualifications for Firefighters, NFPA 1850: Selection, Care and Maintenance of Protective Ensembles

Firefighter I & II Certification cheat sheet: every key fact on one page →