Chapter 1 · Lesson 1 of 5
Two-in/two-out and personnel accountability
Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.
1 min read
OSHA's respiratory protection standard, 29 CFR 1910.134(g)(4), sets the minimum team for interior structural firefighting in an IDLH (immediately dangerous to life or health) atmosphere. At least two firefighters enter together and stay in visual or voice contact.
At least two more stay outside, fully equipped and ready to go in for a rescue. That makes four people as the minimum, which is why exam distractors like to offer four as the number outside.
- One of the two outside members may also serve as incident commander or safety officer, as long as that job does not stop them from performing a rescue.
- The outside pair cannot leave or join the interior attack while the crew is inside; standing by is their whole job.
- The exception: if a person is in imminent, life-threatening danger, a crew may act before the full team is assembled.
Accountability continues once crews are inside. A PAR (personnel accountability report) is a roll call: each company officer confirms that every assigned member is present. Command asks for one at set intervals, after an evacuation, or after a mayday.
Example: Command calls for a PAR after a partial roof collapse. The Ladder 3 officer sees all four members and answers that Ladder 3 has a PAR of four. A PAR says nothing about air refills, finished tasks or a rapid intervention crew.
Check yourself
1. Two firefighters are about to enter a burning house for an interior attack in an IDLH atmosphere. Under OSHA's respiratory protection standard, how many properly equipped firefighters must remain outside, ready to rescue them?
2. Midway through an interior operation, the incident commander requests a PAR (personnel accountability report) from all crews. What is each company officer confirming?
Facts checked 2026-11-15 · Sources: OSHA 29 CFR 1910.134: Respiratory Protection (two-in/two-out, paragraph (g)(4)), NFPA 1010: Professional Qualifications for Firefighters, NFPA 1850: Selection, Care and Maintenance of Protective Ensembles