Chapters0/38 ▾
- 1.Safety, PPE, SCBA & Communications0/5
- 2.Fire Behavior & Building Construction0/5
- 3.Ground Ladders & Forcible Entry0/4
- 4.Search & Rescue and Ventilation0/4
- 5.Water Supply, Hose, Streams & Extinguishers0/5
- 6.Fire Control, Overhaul, Ropes & Knots0/5
- 7.Firefighter II Operations0/5
- 8.Hazmat Awareness & Operations0/5
Chapter 4 · Lesson 4 of 4
Horizontal, PPV, hydraulic and vertical ventilation
Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.
1 min read
| Method | Key rule |
|---|---|
| Natural horizontal | Open the downwind (leeward) exhaust first, then the upwind (windward) intake |
| Positive-pressure (PPV) | Exhaust opening near the fire first; fan outside the door so its cone covers the doorway |
| Hydraulic | Fog covering about 85 to 90 percent of the window, nozzle about 2 ft back (IFSTA) |
| Vertical | As high as safely possible, directly over the fire |
Example: wind blows steadily from the north at a smoky one-story house. The crew opens the south side first as the exhaust, then the north side as the intake. Opening the windward side first lets wind pressurize the house and push smoke deeper.
For PPV, the exhaust should be roughly as large as the intake or larger, the fire must be located, and a line must be ready. In hydraulic ventilation, a straight stream draws little air and a fog wider than the window hits the frame.
On the roof, an opening away from the fire pulls fire across unburned areas, and an eave-level hole is too low. A trench (strip) cut is a long, narrow cut from wall to wall well ahead of fire spreading through a common cockloft; it is defensive and comes after the main hole over the fire.
Work with the wind at your back, keep two escape routes, stand over supports rather than mid-bay, and never assume a roof over a fire will hold.
Check yourself
1. An engine crew is about to start a positive-pressure ventilation (PPV) fan at the front door of a house fire. What must be in place before the fan is turned on?
2. In a long, narrow strip mall with fire spreading through the common cockloft, the officer orders a trench cut. Which statement about this cut is correct?
Facts checked 2026-11-15 · Sources: NFPA 1010: Professional Qualifications for Firefighters, UL FSRI: Impact of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction
Firefighter I & II Certification cheat sheet: every key fact on one page →