Chapter 2 · Lesson 5 of 5
Construction types and collapse hazards
Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.
1 min read
NFPA 220 sorts buildings into Types I to V. The three digits after the type give the required fire-resistance rating in hours for exterior bearing walls, for columns, beams and girders supporting more than one floor, and for floor construction.
So II(000) means zero hours: noncombustible but not fire-resistive. Unprotected steel stretches and loses strength around 1,000°F, so a roof can fail early and expanding steel can push walls out.
- Type III (ordinary): masonry exterior walls, wood interior framing; watch for fire running through the cockloft and wall and ceiling voids.
- Type IV (heavy timber, H in the code): large wood members char slowly and stay stable a long time, with no concealed spaces, but carry a huge fuel load.
- Lightweight wood trusses: gusset plates pull out of charred wood and the whole truss, then its neighbors, can drop within minutes with little warning.
- Balloon framing: studs run from foundation to roof with no fire stops, so check up the stud channels into the attic during overhaul.
Collapse zone: at least 1.5 times the wall height, because bricks bounce and scatter. Example: a bulging 40-foot wall needs a zone of at least 1.5 × 40 = 60 feet.
Check yourself
1. A one-story strip mall has noncombustible walls and a roof of unprotected steel bar joists and metal deck, with no fireproofing. It is classified Type II(000). What does the '000' tell firefighters?
2. A three-story building has load-bearing brick exterior walls, interior floors and roof framed with ordinary-dimension wood joists, and an open cockloft under the roof. Which NFPA 220 type is it, and where is hidden fire spread a key concern?
Facts checked 2026-11-15 · Sources: NFPA 1010: Professional Qualifications for Firefighters, UL FSRI: Impact of Fire Attack Utilizing Interior and Exterior Streams, NFPA 220: Standard on Types of Building Construction
Firefighter I & II Certification cheat sheet: every key fact on one page →