Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/38 ▾
  1. 1.Safety, PPE, SCBA & Communications0/5
    1. Two-in/two-out and personnel accountability
    2. Maydays, emergency traffic and radio discipline
    3. Turnout gear: layers, inspection, retirement and decon
    4. SCBA readiness, air management and emergencies
    5. PASS devices and roadway scene safety
  2. 2.Fire Behavior & Building Construction0/5
    1. The fire tetrahedron, fuel properties and toxic smoke
    2. Heat transfer and reading smoke
    3. Ventilation-limited fires and hostile fire events
    4. Flow paths, closed doors and applying water
    5. Construction types and collapse hazards
  3. 3.Ground Ladders & Forcible Entry0/4
    1. Ladder parts, materials and service testing
    2. Climbing angle, tip placement and power lines
    3. Forcible entry tools and their care
    4. Forcing doors, locks, glass and roll-up gates
  4. 4.Search & Rescue and Ventilation0/4
    1. Primary and secondary search
    2. Moving victims, downed firefighters and VEIS
    3. Flow paths, door control and timing ventilation
    4. Horizontal, PPV, hydraulic and vertical ventilation
  5. 5.Water Supply, Hose, Streams & Extinguishers0/5
    1. Hydrants, water pressure and drafting
    2. Supply hose lays, hose loads and appliances
    3. Hose couplings, rolls and hose care
    4. Fire streams: nozzle pressure, steam and friction loss
    5. Portable extinguishers: classes, ratings and PASS
  6. 6.Fire Control, Overhaul, Ropes & Knots0/5
    1. Life safety rope, utility rope and rope care
    2. Knots and hoisting tools and hoselines
    3. Interior fire attack: direct, indirect and below-grade fires
    4. Vehicle, grass and flammable gas fires
    5. Property conservation and overhaul
  7. 7.Firefighter II Operations0/5
    1. Command and the Incident Command System
    2. Foam, flammable liquids and BLEVE prevention
    3. Sprinklers, standpipes and smoke alarms
    4. Fire cause, evidence and incident reports
    5. Airbag clearance, thermal imaging and hose testing
  8. 8.Hazmat Awareness & Operations0/5
    1. Response levels, training and a safe approach
    2. Placards, NFPA 704 and container shapes
    3. Using the Emergency Response Guidebook
    4. Product behavior, defensive control and public protection
    5. Control zones, decontamination and protection levels
Saved in this browser. Move it to another device →
← Fire Behavior & Building Construction

Chapter 2 · Lesson 5 of 5

Construction types and collapse hazards

Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.

1 min read

NFPA 220 sorts buildings into Types I to V. The three digits after the type give the required fire-resistance rating in hours for exterior bearing walls, for columns, beams and girders supporting more than one floor, and for floor construction.

So II(000) means zero hours: noncombustible but not fire-resistive. Unprotected steel stretches and loses strength around 1,000°F, so a roof can fail early and expanding steel can push walls out.

  • Type III (ordinary): masonry exterior walls, wood interior framing; watch for fire running through the cockloft and wall and ceiling voids.
  • Type IV (heavy timber, H in the code): large wood members char slowly and stay stable a long time, with no concealed spaces, but carry a huge fuel load.
  • Lightweight wood trusses: gusset plates pull out of charred wood and the whole truss, then its neighbors, can drop within minutes with little warning.
  • Balloon framing: studs run from foundation to roof with no fire stops, so check up the stud channels into the attic during overhaul.

Collapse zone: at least 1.5 times the wall height, because bricks bounce and scatter. Example: a bulging 40-foot wall needs a zone of at least 1.5 × 40 = 60 feet.

Check yourself

1. A one-story strip mall has noncombustible walls and a roof of unprotected steel bar joists and metal deck, with no fireproofing. It is classified Type II(000). What does the '000' tell firefighters?

2. A three-story building has load-bearing brick exterior walls, interior floors and roof framed with ordinary-dimension wood joists, and an open cockloft under the roof. Which NFPA 220 type is it, and where is hidden fire spread a key concern?

Facts checked 2026-11-15 · Sources: NFPA 1010: Professional Qualifications for Firefighters, UL FSRI: Impact of Fire Attack Utilizing Interior and Exterior Streams, NFPA 220: Standard on Types of Building Construction

Firefighter I & II Certification cheat sheet: every key fact on one page →