Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/38 ▾
  1. 1.Safety, PPE, SCBA & Communications0/5
    1. Two-in/two-out and personnel accountability
    2. Maydays, emergency traffic and radio discipline
    3. Turnout gear: layers, inspection, retirement and decon
    4. SCBA readiness, air management and emergencies
    5. PASS devices and roadway scene safety
  2. 2.Fire Behavior & Building Construction0/5
    1. The fire tetrahedron, fuel properties and toxic smoke
    2. Heat transfer and reading smoke
    3. Ventilation-limited fires and hostile fire events
    4. Flow paths, closed doors and applying water
    5. Construction types and collapse hazards
  3. 3.Ground Ladders & Forcible Entry0/4
    1. Ladder parts, materials and service testing
    2. Climbing angle, tip placement and power lines
    3. Forcible entry tools and their care
    4. Forcing doors, locks, glass and roll-up gates
  4. 4.Search & Rescue and Ventilation0/4
    1. Primary and secondary search
    2. Moving victims, downed firefighters and VEIS
    3. Flow paths, door control and timing ventilation
    4. Horizontal, PPV, hydraulic and vertical ventilation
  5. 5.Water Supply, Hose, Streams & Extinguishers0/5
    1. Hydrants, water pressure and drafting
    2. Supply hose lays, hose loads and appliances
    3. Hose couplings, rolls and hose care
    4. Fire streams: nozzle pressure, steam and friction loss
    5. Portable extinguishers: classes, ratings and PASS
  6. 6.Fire Control, Overhaul, Ropes & Knots0/5
    1. Life safety rope, utility rope and rope care
    2. Knots and hoisting tools and hoselines
    3. Interior fire attack: direct, indirect and below-grade fires
    4. Vehicle, grass and flammable gas fires
    5. Property conservation and overhaul
  7. 7.Firefighter II Operations0/5
    1. Command and the Incident Command System
    2. Foam, flammable liquids and BLEVE prevention
    3. Sprinklers, standpipes and smoke alarms
    4. Fire cause, evidence and incident reports
    5. Airbag clearance, thermal imaging and hose testing
  8. 8.Hazmat Awareness & Operations0/5
    1. Response levels, training and a safe approach
    2. Placards, NFPA 704 and container shapes
    3. Using the Emergency Response Guidebook
    4. Product behavior, defensive control and public protection
    5. Control zones, decontamination and protection levels
Saved in this browser. Move it to another device →
← Fire Behavior & Building Construction

Chapter 2 · Lesson 4 of 5

Flow paths, closed doors and applying water

Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.

1 min read

A flow path runs from a higher-pressure inlet to a lower-pressure exhaust, and heat and fire gases travel along it. Anyone standing between the fire and the exhaust faces rapidly rising heat and gas speed. Wind makes this worse.

Example: wind blows into a broken kitchen window at the rear, and a crew opens the front door to enter. The hallway between the kitchen and that door is now in the flow path, and conditions there can turn deadly in seconds.

UL FSRI research has reshaped several exam answers. A victim behind a closed bedroom door had survivable temperature, carbon monoxide and oxygen levels far longer than one behind an open door, which is the basis of the close-the-door message.

In full-scale tests in UL's fire lab, a brief exterior straight stream into the fire room, followed by interior attack (a transitional attack), lowered temperatures through the house and did not push fire into other rooms or raise burn risk to occupants. Water applied into the fire area did not push fire.

Overusing fog has a different cost. A wide fog held in a stable hot layer makes large amounts of steam, upsets the thermal layering and drives heat and steam down onto the crew, and visibility gets worse.

Check yourself

1. Fire is venting from a bedroom window on the side of a house. The crew briefly flows a straight stream through that window toward the ceiling of the room, then advances inside. According to UL FSRI fire attack research, this exterior application:

2. Wind is blowing into a failed window at the back of a house, and the fire is in a rear room. The crew opens the front door, which becomes the exhaust. A firefighter in the hallway between the fire and the front door is in the flow path. What should they expect?

Facts checked 2026-11-15 · Sources: NFPA 1010: Professional Qualifications for Firefighters, UL FSRI: Impact of Fire Attack Utilizing Interior and Exterior Streams, NFPA 220: Standard on Types of Building Construction

Firefighter I & II Certification cheat sheet: every key fact on one page →