Chapters0/38 ▾
- 1.Safety, PPE, SCBA & Communications0/5
- 2.Fire Behavior & Building Construction0/5
- 3.Ground Ladders & Forcible Entry0/4
- 4.Search & Rescue and Ventilation0/4
- 5.Water Supply, Hose, Streams & Extinguishers0/5
- 6.Fire Control, Overhaul, Ropes & Knots0/5
- 7.Firefighter II Operations0/5
- 8.Hazmat Awareness & Operations0/5
Chapter 6 · Lesson 3 of 5
Interior fire attack: direct, indirect and below-grade fires
Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.
1 min read
A direct attack puts water straight onto the burning fuel. An indirect attack aims the stream into the overhead of a closed compartment to turn water into steam, and a combination attack mixes the two.
Because the indirect method fills the space with heat and steam, it is used only when no victims or crews are inside. It fits a fully involved, unoccupied, closed room where steam conversion is the goal.
Nozzle handling matters as much as stream choice. Water hammer is a pressure surge created when moving water stops suddenly, so nozzles are opened and closed gradually to protect hose, pump and fittings.
Large-scale tests by UL's Fire Safety Research Institute found that water applied into the fire area did not push fire into other rooms, which supports getting water onto the fire quickly.
Basement fires are a common scene. An interior stairway above a basement fire acts like a chimney for heat and smoke, so a crew going down it walks through the heat column.
Unless directed otherwise, the preferred approach is an outside basement door or another grade-level entry. Example: a split-level house has fire in the lower level and a walkout door at the back; the line goes in through that door, not down the kitchen stairs.
Check yourself
1. In which situation is an indirect attack (directing the stream into the overhead to make steam) inappropriate?
2. Fire is burning in a basement. The only interior stairs lead down from the first floor, and an outside basement door is available. Unless directed otherwise, what is the preferred attack approach?
Facts checked 2026-11-15 · Sources: NFPA 1010 (2024): Professional Qualifications for Firefighters, NFPA 2500: life safety rope and equipment for emergency services, UL Fire Safety Research Institute: fire attack research
Firefighter I & II Certification cheat sheet: every key fact on one page →