Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/38 ▾
  1. 1.Safety, PPE, SCBA & Communications0/5
    1. Two-in/two-out and personnel accountability
    2. Maydays, emergency traffic and radio discipline
    3. Turnout gear: layers, inspection, retirement and decon
    4. SCBA readiness, air management and emergencies
    5. PASS devices and roadway scene safety
  2. 2.Fire Behavior & Building Construction0/5
    1. The fire tetrahedron, fuel properties and toxic smoke
    2. Heat transfer and reading smoke
    3. Ventilation-limited fires and hostile fire events
    4. Flow paths, closed doors and applying water
    5. Construction types and collapse hazards
  3. 3.Ground Ladders & Forcible Entry0/4
    1. Ladder parts, materials and service testing
    2. Climbing angle, tip placement and power lines
    3. Forcible entry tools and their care
    4. Forcing doors, locks, glass and roll-up gates
  4. 4.Search & Rescue and Ventilation0/4
    1. Primary and secondary search
    2. Moving victims, downed firefighters and VEIS
    3. Flow paths, door control and timing ventilation
    4. Horizontal, PPV, hydraulic and vertical ventilation
  5. 5.Water Supply, Hose, Streams & Extinguishers0/5
    1. Hydrants, water pressure and drafting
    2. Supply hose lays, hose loads and appliances
    3. Hose couplings, rolls and hose care
    4. Fire streams: nozzle pressure, steam and friction loss
    5. Portable extinguishers: classes, ratings and PASS
  6. 6.Fire Control, Overhaul, Ropes & Knots0/5
    1. Life safety rope, utility rope and rope care
    2. Knots and hoisting tools and hoselines
    3. Interior fire attack: direct, indirect and below-grade fires
    4. Vehicle, grass and flammable gas fires
    5. Property conservation and overhaul
  7. 7.Firefighter II Operations0/5
    1. Command and the Incident Command System
    2. Foam, flammable liquids and BLEVE prevention
    3. Sprinklers, standpipes and smoke alarms
    4. Fire cause, evidence and incident reports
    5. Airbag clearance, thermal imaging and hose testing
  8. 8.Hazmat Awareness & Operations0/5
    1. Response levels, training and a safe approach
    2. Placards, NFPA 704 and container shapes
    3. Using the Emergency Response Guidebook
    4. Product behavior, defensive control and public protection
    5. Control zones, decontamination and protection levels
Saved in this browser. Move it to another device →
← Hazmat Awareness & Operations

Chapter 8 · Lesson 5 of 5

Control zones, decontamination and protection levels

Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.

1 min read

Scenes are split into three zones. The hot zone surrounds the release.

The warm zone is the contamination reduction area and is where the decontamination corridor goes, placed upwind and uphill of the hot zone so vapor and runoff do not reach it. The cold zone stays clean for command and staging, so decon never goes beside the command post, and never downwind of the release.

Example: wind is from the east and the spill is at a loading dock; set the decon corridor in the warm zone on the east side, on higher ground.

Mass decontamination of many victims uses a high volume of water at low pressure, which flushes the contaminant off without driving it into the skin; removing clothing first takes off most of it. High-pressure streams and waiting for EMS are wrong.

When the hazards are not yet identified, OSHA 29 CFR 1910.120(c)(5)(iii) makes Level B, with SCBA, the minimum, and at an emergency response (q)(3)(iv) keeps responders on positive-pressure SCBA until air monitoring shows less protection is safe.

Level C air-purifying respirators are allowed only when the contaminant and its concentration are known, oxygen is at least 19.5 percent, and the air is not IDLH. Level D gives no respiratory protection. Example: crews entering a basement with an unidentified chemical odor wear SCBA with splash protection, not a cartridge respirator.

Check yourself

1. For an atmosphere containing an unidentified airborne contaminant at an unknown concentration, what is generally the minimum EPA level of protection for entry?

2. Dozens of people are contaminated with an unknown liquid after an incident at a transit station, and engine companies set up a mass decontamination corridor. How should the water be applied?

Facts checked 2026-11-15 · Sources: NFPA 470: Hazardous Materials Standard for Responders, OSHA 29 CFR 1910.120: Hazardous Waste Operations and Emergency Response, PHMSA: Emergency Response Guidebook (ERG 2024)

Firefighter I & II Certification cheat sheet: every key fact on one page →