Chapter 8 · Lesson 5 of 5
Control zones, decontamination and protection levels
Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.
1 min read
Scenes are split into three zones. The hot zone surrounds the release.
The warm zone is the contamination reduction area and is where the decontamination corridor goes, placed upwind and uphill of the hot zone so vapor and runoff do not reach it. The cold zone stays clean for command and staging, so decon never goes beside the command post, and never downwind of the release.
Example: wind is from the east and the spill is at a loading dock; set the decon corridor in the warm zone on the east side, on higher ground.
Mass decontamination of many victims uses a high volume of water at low pressure, which flushes the contaminant off without driving it into the skin; removing clothing first takes off most of it. High-pressure streams and waiting for EMS are wrong.
When the hazards are not yet identified, OSHA 29 CFR 1910.120(c)(5)(iii) makes Level B, with SCBA, the minimum, and at an emergency response (q)(3)(iv) keeps responders on positive-pressure SCBA until air monitoring shows less protection is safe.
Level C air-purifying respirators are allowed only when the contaminant and its concentration are known, oxygen is at least 19.5 percent, and the air is not IDLH. Level D gives no respiratory protection. Example: crews entering a basement with an unidentified chemical odor wear SCBA with splash protection, not a cartridge respirator.
Check yourself
1. For an atmosphere containing an unidentified airborne contaminant at an unknown concentration, what is generally the minimum EPA level of protection for entry?
2. Dozens of people are contaminated with an unknown liquid after an incident at a transit station, and engine companies set up a mass decontamination corridor. How should the water be applied?
Facts checked 2026-11-15 · Sources: NFPA 470: Hazardous Materials Standard for Responders, OSHA 29 CFR 1910.120: Hazardous Waste Operations and Emergency Response, PHMSA: Emergency Response Guidebook (ERG 2024)