Chapters0/54 ▾
- 1.Architecture & Log Sources0/5
- 2.Indicators of Malicious Activity0/5
- 3.Investigation Tools & Threat Hunting0/5
- 4.Process Improvement, Automation & AI0/5
- 5.Vulnerability Scanning Methods0/5
- 6.Analyzing Scan Output0/5
- 7.Prioritization, Mitigation & Controls0/5
- 8.Attack Frameworks & the Response Process0/5
- 9.Incident Response Techniques0/5
- 10.Vulnerability Reporting & Communication0/5
- 11.Incident Reporting & Metrics0/4
Chapter 1 · Lesson 1 of 5
What each log source can and cannot prove
1 min read
Every log is written from one vantage point, and it can only contain what that vantage point could observe. A network device sees packets, so it can record addresses, ports, byte counts and timing.
It never sees which program on the host opened the socket or which person was signed in. The exam builds many questions on this gap: an answer that claims a network record names a user or a process is almost always wrong.
| Source | What it records | What it cannot tell you |
|---|---|---|
| Flow records | Hosts, ports, protocol, bytes, duration | User, process or payload |
| Firewall without a proxy | Allowed or denied connections | Full URLs requested |
| DNS resolver log | Names queried and answers | The page path or the requesting program |
| Endpoint agent | Process, parent, command line, logon session, sockets | Hosts where it is not installed |
Shared identities create the same problem one layer up. If a web application connects to its database through one pooled service account, the database audit log proves what statement ran and when, but only the application's own session log can say which end user triggered it. Example: a sensor shows 2 GB leaving a terminal server used by 15 people.
The flow proves the volume and the destination; the endpoint agent's process and logon data is what ties it to one account.
Check yourself
1. A network sensor logs a TLS session from a workstation to a suspicious host: server name indication, certificate details, byte counts and duration, with no payload visible. The analyst must determine which executable on the workstation opened that connection. What is the best source?
2. Flow records from a core router show 4.2 GB transferred from a file server to an external address over forty minutes on TCP 443. Management asks which employee account moved the data. What do the flow records establish, and which source answers the question?
Facts checked 2026-11-15 · Sources: CompTIA CySA+ (CS0-004) certification page and exam objectives, NIST SP 800-92, Guide to Computer Security Log Management
CompTIA CySA+ cheat sheet: every key fact on one page →