A timeline built from several sources is only as good as the clocks behind it. If one server's time drifts after NTP fails, its events can appear to happen before the request that caused them, which reverses cause and effect.
The correct response is never to throw that source away. Measure the offset, apply it as a correction, rebuild the timeline against one reference clock, and fix the synchronization so the drift stops.
- Ingest time is not event time: forwarding and queuing delays differ by source, so arrival order at the SIEM can be wrong.
- Converting skewed values into another time zone moves them all equally and leaves the skew in place.
- A local timestamp with no recorded offset is ambiguous, and when clocks fall back for daylight saving one local hour happens twice.
The fix for mixed time zones is to normalize every entry to UTC at ingestion while keeping the original string. Normalization has a cost the exam likes to test: a parser keeps only the fields it maps.
If it drops the client source port, you can no longer separate the many hosts that share one address behind a NAT gateway. The raw record, usually still held by the collector, is where you recover it.
Check yourself
1. Two plants write their application logs in local wall-clock time with no offset recorded in the entry. One plant observes daylight saving time; the other does not. An analyst must order events from both plants across the night the clocks changed. What is the correct assessment?
2. An analyst correlates a firewall log, a web server log and a domain controller log for the same intrusion. NTP failed on the domain controller three weeks ago and its clock now runs seven minutes ahead of the other two sources. What should the analyst do about the timeline?
Facts checked 2026-11-15 · Sources: CompTIA CySA+ (CS0-004) certification page and exam objectives, NIST SP 800-92, Guide to Computer Security Log Management