Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/28 ▾
  1. 1.General Medical Knowledge & History0/4
    1. Taking and documenting the ophthalmic history
    2. Triage: which eye complaints cannot wait
    3. Eye anatomy and physiology the exam expects
    4. Systemic disease, medications and chart terms
  2. 2.Visual Acuity, Pupils & Motility0/4
    1. Measuring and recording visual acuity
    2. The pupil exam and the afferent pupillary defect
    3. Extraocular muscles and the cardinal positions of gaze
    4. Cover tests, stereopsis and convergence
  3. 3.Tonometry, Visual Fields & Biometry0/4
    1. Goldmann applanation tonometry and its errors
    2. Visual fields: reading defects and avoiding artifacts
    3. Biometry: measuring axial length for lens implants
    4. Supplemental tests: Amsler grid, color vision and glare
  4. 4.Refraction, Lensometry & Optics0/4
    1. Reading a prescription: transposition, spherical equivalent and vertex
    2. Retinoscopy and subjective refraction endpoints
    3. Lensometry: reading glasses and prism
    4. Keratometry and corneal astigmatism
  5. 5.Ophthalmic Imaging & Photography0/4
    1. Fluorescein angiography: filters, phases and what the frames show
    2. Dye studies: screening, side effects and reactions
    3. OCT, corneal topography and ultrasound
    4. Photography technique, slit-lamp lighting and labeling
  6. 6.Pharmacology, Microbiology & Surgical Assisting0/4
    1. How dilating, numbing and pressure-lowering drops work
    2. Giving drops and dyes safely
    3. Germs, hand hygiene and cleaning clinic equipment
    4. Sterile technique and assisting with minor surgery
  7. 7.Patient Services, Equipment & Ethics0/4
    1. Teaching patients to use eye drops and stay on treatment
    2. Communicating, identifying patients and triaging urgent calls
    3. Caring for tonometers, lenses and other equipment
    4. Consent, privacy, scope of practice and reporting errors
Saved in this browser. Move it to another device →
← Tonometry, Visual Fields & Biometry

Chapter 3 · Lesson 1 of 4

Goldmann applanation tonometry and its errors

1 min read

Applanation estimates intraocular pressure from the force needed to flatten a standard area of cornea. That area was chosen because at that size the cornea's own rigidity, which resists flattening, and the tear film's surface tension, which pulls the prism toward the eye, cancel each other out.

Under the cobalt blue light you see two fluorescein semicircles and turn the dial until their inner edges just touch. If the semicircles pulsate with the heartbeat, read the middle of the swing.

SituationEffect on reading
Too much fluorescein, tearing or a wet lid (thick mires)Reads high
Too little fluorescein (faint, thin mires)Reads low
Thin cornea, including after laser vision correctionReads low
Breath holding, tight collar, lid squeezing, fingers pressing the globeReads high

Example: a patient measured 15 mmHg last visit and reads 26 mmHg today while holding his breath and squeezing. Relax him, hold the lids on the bony rim without touching the globe, repeat, and report the confirmed value with the eye, method and time.

Telling him what the number means is a diagnosis. Defer contact tonometry when the cornea has an epithelial defect or possible infection, and let the physician decide. A reusable tip is disinfected and then rinsed and dried, because leftover disinfectant injures the corneal surface.

Check yourself

1. What is the correct endpoint for the fluorescein mires during applanation, and what should be done if they pulsate with the ocular pulse?

2. Goldmann applanation tonometry estimates intraocular pressure from the force needed to flatten a standardized area of cornea. Why is that particular flattened area used?

Facts checked 2026-11-15 · Sources: IJCAHPO: Certified Ophthalmic Assistant (COA) certification and exam content areas, National Eye Institute: Glaucoma

Ophthalmic Assistant (COA) cheat sheet: every key fact on one page →