Applanation estimates intraocular pressure from the force needed to flatten a standard area of cornea. That area was chosen because at that size the cornea's own rigidity, which resists flattening, and the tear film's surface tension, which pulls the prism toward the eye, cancel each other out.
Under the cobalt blue light you see two fluorescein semicircles and turn the dial until their inner edges just touch. If the semicircles pulsate with the heartbeat, read the middle of the swing.
| Situation | Effect on reading |
|---|---|
| Too much fluorescein, tearing or a wet lid (thick mires) | Reads high |
| Too little fluorescein (faint, thin mires) | Reads low |
| Thin cornea, including after laser vision correction | Reads low |
| Breath holding, tight collar, lid squeezing, fingers pressing the globe | Reads high |
Example: a patient measured 15 mmHg last visit and reads 26 mmHg today while holding his breath and squeezing. Relax him, hold the lids on the bony rim without touching the globe, repeat, and report the confirmed value with the eye, method and time.
Telling him what the number means is a diagnosis. Defer contact tonometry when the cornea has an epithelial defect or possible infection, and let the physician decide. A reusable tip is disinfected and then rinsed and dried, because leftover disinfectant injures the corneal surface.
Check yourself
1. What is the correct endpoint for the fluorescein mires during applanation, and what should be done if they pulsate with the ocular pulse?
2. Goldmann applanation tonometry estimates intraocular pressure from the force needed to flatten a standardized area of cornea. Why is that particular flattened area used?
Facts checked 2026-11-15 · Sources: IJCAHPO: Certified Ophthalmic Assistant (COA) certification and exam content areas, National Eye Institute: Glaucoma
Ophthalmic Assistant (COA) cheat sheet: every key fact on one page →