Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/28 ▾
  1. 1.General Medical Knowledge & History0/4
    1. Taking and documenting the ophthalmic history
    2. Triage: which eye complaints cannot wait
    3. Eye anatomy and physiology the exam expects
    4. Systemic disease, medications and chart terms
  2. 2.Visual Acuity, Pupils & Motility0/4
    1. Measuring and recording visual acuity
    2. The pupil exam and the afferent pupillary defect
    3. Extraocular muscles and the cardinal positions of gaze
    4. Cover tests, stereopsis and convergence
  3. 3.Tonometry, Visual Fields & Biometry0/4
    1. Goldmann applanation tonometry and its errors
    2. Visual fields: reading defects and avoiding artifacts
    3. Biometry: measuring axial length for lens implants
    4. Supplemental tests: Amsler grid, color vision and glare
  4. 4.Refraction, Lensometry & Optics0/4
    1. Reading a prescription: transposition, spherical equivalent and vertex
    2. Retinoscopy and subjective refraction endpoints
    3. Lensometry: reading glasses and prism
    4. Keratometry and corneal astigmatism
  5. 5.Ophthalmic Imaging & Photography0/4
    1. Fluorescein angiography: filters, phases and what the frames show
    2. Dye studies: screening, side effects and reactions
    3. OCT, corneal topography and ultrasound
    4. Photography technique, slit-lamp lighting and labeling
  6. 6.Pharmacology, Microbiology & Surgical Assisting0/4
    1. How dilating, numbing and pressure-lowering drops work
    2. Giving drops and dyes safely
    3. Germs, hand hygiene and cleaning clinic equipment
    4. Sterile technique and assisting with minor surgery
  7. 7.Patient Services, Equipment & Ethics0/4
    1. Teaching patients to use eye drops and stay on treatment
    2. Communicating, identifying patients and triaging urgent calls
    3. Caring for tonometers, lenses and other equipment
    4. Consent, privacy, scope of practice and reporting errors
Saved in this browser. Move it to another device →
← Refraction, Lensometry & Optics

Chapter 4 · Lesson 4 of 4

Keratometry and corneal astigmatism

1 min read

A keratometer measures the curvature of the central front cornea along its two principal meridians. Radius and power are linked by a reciprocal formula: power in diopters equals 337.5 divided by the radius in millimeters.

A shorter radius is a steeper, stronger cornea. Example: a radius of 7.80 mm gives 337.5 / 7.80 = 43.27 D, and a flatter 8.00 mm gives 42.19 D.

Corneal astigmatism is the steep reading minus the flat reading, and the steep meridian names the type: near 090 is with-the-rule, near 180 is against-the-rule, and well away from both is oblique.

Example: 43.50 @ 180 and 42.25 @ 090. The steep meridian is at 180, so this is 1.25 D of against-the-rule astigmatism. Corneal astigmatism is not the same as total refractive astigmatism, because the crystalline lens adds its own.

The mires reflect off the tear film, so broken, distorted mires in a patient with burning and blur call for a blink or lubrication and a repeat before anything is reported. If readings look normal but vision fluctuates and the cornea looks irregular, topography is the next step, because keratometry samples only a few central points.

Check yourself

1. Corneal power in diopters equals 337.5 divided by the radius of curvature in millimeters. A radius of 7.50 mm corresponds to:

2. Keratometry readings look normal, but the patient's vision fluctuates and the cornea appears irregular at the slit lamp. The most useful next measurement is:

Facts checked 2026-11-15 · Sources: IJCAHPO: Certified Ophthalmic Assistant (COA) certification and exam content areas, AAO EyeWiki: Retinoscopy, AAO EyeWiki: Lensometry