Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/28 ▾
  1. 1.General Medical Knowledge & History0/4
    1. Taking and documenting the ophthalmic history
    2. Triage: which eye complaints cannot wait
    3. Eye anatomy and physiology the exam expects
    4. Systemic disease, medications and chart terms
  2. 2.Visual Acuity, Pupils & Motility0/4
    1. Measuring and recording visual acuity
    2. The pupil exam and the afferent pupillary defect
    3. Extraocular muscles and the cardinal positions of gaze
    4. Cover tests, stereopsis and convergence
  3. 3.Tonometry, Visual Fields & Biometry0/4
    1. Goldmann applanation tonometry and its errors
    2. Visual fields: reading defects and avoiding artifacts
    3. Biometry: measuring axial length for lens implants
    4. Supplemental tests: Amsler grid, color vision and glare
  4. 4.Refraction, Lensometry & Optics0/4
    1. Reading a prescription: transposition, spherical equivalent and vertex
    2. Retinoscopy and subjective refraction endpoints
    3. Lensometry: reading glasses and prism
    4. Keratometry and corneal astigmatism
  5. 5.Ophthalmic Imaging & Photography0/4
    1. Fluorescein angiography: filters, phases and what the frames show
    2. Dye studies: screening, side effects and reactions
    3. OCT, corneal topography and ultrasound
    4. Photography technique, slit-lamp lighting and labeling
  6. 6.Pharmacology, Microbiology & Surgical Assisting0/4
    1. How dilating, numbing and pressure-lowering drops work
    2. Giving drops and dyes safely
    3. Germs, hand hygiene and cleaning clinic equipment
    4. Sterile technique and assisting with minor surgery
  7. 7.Patient Services, Equipment & Ethics0/4
    1. Teaching patients to use eye drops and stay on treatment
    2. Communicating, identifying patients and triaging urgent calls
    3. Caring for tonometers, lenses and other equipment
    4. Consent, privacy, scope of practice and reporting errors
Saved in this browser. Move it to another device →
← Refraction, Lensometry & Optics

Chapter 4 · Lesson 2 of 4

Retinoscopy and subjective refraction endpoints

1 min read

Refraction questions on the COA exam test a handful of rules, each with a reason you can reconstruct under pressure.

  • Retinoscopy (IJCAHPO lists it from the COT level up, so expect little of it on the COA exam): with-motion means add plus, against-motion means add minus, and at neutrality the reflex fills the pupil and stops moving.
  • Maximum plus: record the least minus that still reads the best line, because extra minus is focused by the patient's own accommodation and causes eyestrain later.
  • Duochrome: red clearer means add minus, green clearer means add plus. The test judges blur, not hue, so it still works in color-deficient patients.
  • Cross cylinder: refine the axis first, then the power, because a wrong axis blurs both meridians.
  • Binocular balance by prism dissociation is valid only when both eyes reach the same best corrected acuity.

When the cross cylinder changes the cylinder power, move the sphere half that amount the other way so the spherical equivalent stays put.

Example: -2.00 -1.00 x 180 refines to 0.50 D more minus cylinder, so the new lens is -1.75 -1.50 x 180, and both have a spherical equivalent of -2.50 D. Cycloplegia is used in children, especially with esotropia, because a strong accommodation can hide hyperopia; presbyopes need a plus add because the stiffening crystalline lens can no longer add power for near.

Check yourself

1. A patient reads the 20/20 line with -2.25 sphere and again with -2.50 sphere. Which sphere should be recorded?

2. During streak retinoscopy, the reflex in the pupil moves in the same direction as the sweep of the streak. To reach neutrality, the examiner should:

Facts checked 2026-11-15 · Sources: IJCAHPO: Certified Ophthalmic Assistant (COA) certification and exam content areas, AAO EyeWiki: Retinoscopy, AAO EyeWiki: Lensometry

Ophthalmic Assistant (COA) cheat sheet: every key fact on one page →