Chapters0/23 ▾
Chapter 3 · Lesson 4 of 4
Access problems during and after treatment
1 min read
Infiltration happens when the needle tip leaves the vessel and blood is pumped into the tissue. The patient feels burning and the area swells quickly and darkens.
Every second of pumping makes it worse, so the technician stops the pump, clamps, removes the needle and holds pressure, then notifies the nurse. Ice is applied per protocol during the first day, and any new needle goes away from the injured area.
At the end of treatment, the needle comes out completely at the angle it went in before any pressure is applied, because pressing while the bevel is still inside can cut the vessel wall.
Pressure must cover both the skin hole and the deeper vessel hole, firm enough to stop bleeding but light enough that the thrill can still be felt. Pressure that wipes out the thrill can clot the access.
Catheters lead straight into a central vein. When connecting or disconnecting, both the patient and staff wear masks, each hub is scrubbed with antiseptic, lumens are never left open to air, and the lock solution is drawn off and discarded rather than flushed into the patient.
Example: shaking chills begin soon after a catheter is connected and the exit-site dressing is loose with drainage. That points to a catheter-related bloodstream infection, and the technician reports it to the nurse now and records the findings.
Check yourself
1. What is the correct technique for achieving hemostasis after the needles are removed at the end of treatment?
2. Mrs. Chen dialyzes through a tunneled cuffed catheter. Which practice should the technician follow when connecting and disconnecting the bloodlines?
Facts checked 2026-11-15 · Sources: NNCC: Certified Clinical Hemodialysis Technician (CCHT), CDC: Recommendations for Preventing Transmission of Infections Among Chronic Hemodialysis Patients
Dialysis Technician cheat sheet: every key fact on one page →