Chapters0/30 ▾
- 1.Asepsis & Sterile Technique0/5
- Where sterile ends: gowns, tables, movement and the prep
- Breaks in technique: strike-through, glove punctures and wound class
- Judging packages, trays and solutions before they reach the field
- Reading sterilization indicators and biological results
- Cleaning first, Spaulding, and choosing a sterilization method
- 2.Instrumentation & Sutures0/5
- 3.Surgical Procedures0/5
- 4.Patient Safety & Counts0/5
- 5.Professional Practice0/5
- Informed consent: who explains, who witnesses, who may sign
- Roles, scope of practice and owning your errors
- Documentation: count records, corrections and occurrence reports
- Legal doctrines: negligence, res ipsa loquitur, respondeat superior, battery and abandonment
- Privacy, do-not-resuscitate orders and advance directives
- 6.Basic Science0/5
Chapter 3 · Lesson 2 of 5
The instrument each step calls for
1 min read
Many procedure questions describe a step and ask what to pass. The answer usually comes from the shape of the task.
Something that must go behind a structure needs a bent tip; something that must be held open for a long time needs a self-retaining device; bone near a nerve needs a tool that cuts away from it. Kelly, Babcock and Allis clamps are graspers, so they are wrong whenever the task is to tunnel behind a duct or vessel.
| Step | What to pass |
|---|---|
| Clamping uterine and cardinal ligament pedicles | Heaney clamp, with a tooth at the tip |
| Drawing a tie behind the cystic duct | Right-angle clamp |
| Spreading ribs in a thoracotomy | Self-retaining rib spreader |
| Removing lamina over a nerve root | Kerrison-type rongeur with a thin footplate |
| Incising the scalp flap | Scalp clips on an applier |
Orthopedic plating follows a fixed order: drill, measure, tap, insert. The depth gauge comes right after the drill so the screw length is known before threads are cut. Example: the drill has just passed through both cortices.
The next pass is the depth gauge, then the tap, then the screwdriver with a screw of the measured length. Skipping the gauge risks a screw too short to hold or long enough to injure structures beyond the bone.
Check yourself
1. In plating a fracture, after the hole is drilled through both cortices, the technologist next passes:
2. The surgeon asks for the clamp used to dissect behind the cystic duct and draw a tie around it. You pass:
Facts checked 2026-11-15 · Sources: NBSTSA: Surgical Technologist Certifying Examination Content Outline, Association of Surgical Technologists: Standards of Practice
Surgical Technologist (CST) cheat sheet: every key fact on one page →