Surgical Technologist (CST) Cheat Sheet: Key Facts
Every key takeaway and common trap from the Surgical Technologist (CST) study guide on one page, grouped by chapter. Tap a lesson link to read the full explanation.
46 facts · 6 chaptersFacts checked 2026-11-16
Chapter 1
Asepsis & Sterile Technique
Key takeaways
- A sterile gown is sterile only in front from mid-chest to field level and on the sleeves from the cuff to about two inches above the elbow, and a draped table is sterile only at table-top level. → Where sterile ends: gowns, tables, movement and the prep
- Anyone who sees a break in technique names it out loud at once, whoever caused it. → Breaks in technique: strike-through, glove punctures and wound class
- Sterility is event-related: a tear, moisture or a drop decides whether a package can be used, not the printed date. → Judging packages, trays and solutions before they reach the field
- Only a biological indicator proves that a cycle killed spores, so implant loads are held until it is read and a positive result recalls every load back to the last negative one. → Reading sterilization indicators and biological results
- Cleaning always comes first, and the Spaulding class of a device is set by the tissue it will touch. → Cleaning first, Spaulding, and choosing a sterilization method
Common trap
- Pulling a second glove over a punctured one looks fast, but it traps contamination against the hand. The fix for a glove breach with an intact gown is to remove the damaged glove and reglove; the gown is changed only if the gown itself is contaminated. → Breaks in technique: strike-through, glove punctures and wound class
- A changed color strip or a passing integrating indicator is never proof of sterility. Answers that release an implant, or call a package sterile, on a chemical indicator alone are wrong outside a documented emergency. → Reading sterilization indicators and biological results
- When a question names a delicate scope, check its tolerance before its convenience. A prevacuum steam cycle, or a soak in alcohol, sounds gentle or quick, but steam harms a heat-sensitive device and alcohol does not kill spores. → Cleaning first, Spaulding, and choosing a sterilization method
Quick reference
| Situation | Correct response |
|---|---|
| Fluid soaks through a drape | Strike-through contaminates the area even if the fluid was sterile; cover it with more sterile drape or replace it |
| Glove punctured, gown intact | Step back, have the glove removed, and be regloved by a sterile team member |
| Initial gloving after the scrub | Closed gloving, hands kept inside the cuffs |
| Spaulding class | Tissue contacted | Minimum processing |
|---|---|---|
| Critical | Sterile tissue or the vascular system | Sterilization |
| Semicritical | Mucous membranes or non-intact skin | Sterilization or at least high-level disinfection |
| Noncritical | Intact skin | Low-level disinfection |
Chapter 2
Instrumentation & Sutures
Key takeaways
- Match the jaw to the tissue: fine atraumatic serrations for vessels, broad smooth fenestrated jaws for bowel, teeth only for tough tissue. → Reading an instrument by its jaws, blades and tip
- Instruments are passed handle first into the palm, and sharps move through a neutral zone so only one person holds them at a time. → Retractors, passing technique, sharps and instrument care
- Each added zero on the USP suture scale means a finer strand, so 5-0 is finer than 2-0. → Suture size, monofilament versus braided, and ligatures
- Taper points suit easily penetrated tissue, reverse cutting points suit tough tissue such as skin, and blunt points suit friable organs. → Needle points, loading the needle holder, and staplers
- Bipolar current stays between the forceps tips, while monopolar current crosses the body and can stray through insulation failure, direct coupling or capacitive coupling. → Hemostasis categories, electrosurgery and powered equipment
Common trap
- Saying the word sharp during a hand-to-hand pass is better than silence, but it is not the safest answer. When an option offers a neutral zone, it removes the moment when two people hold the sharp together. → Retractors, passing technique, sharps and instrument care
- Do not rank suture sizes like ordinary numbers. A plain 2 is heavier than 1, but 2-0 is finer than 0, so a question asking for the finest strand wants the size with the most zeros. → Suture size, monofilament versus braided, and ligatures
- Bone wax is not a chemical or clotting agent. It works only by plugging channels in the bone, so it belongs with mechanical hemostasis. → Hemostasis categories, electrosurgery and powered equipment
Quick reference
| Need | Feature to look for |
|---|---|
| Occlude an artery that must stay healthy | Fine, shallow, atraumatic serrations with light closing pressure |
| Hold a loop of bowel | Broad, smooth, fenestrated jaws that spread the pressure |
| Dissect a delicate plane | Long shanks with short, fine, blunt-tipped curved blades |
| Clear a large pool of fluid | Large-bore rigid suction tip with a guard |
| Needle point | How it passes | Typical tissue |
|---|---|---|
| Taper | Spreads fibers, leaves the smallest hole | Bowel, peritoneum, vessels |
| Reverse cutting | Third edge on the outer curve, away from the wound edge | Skin and other tough tissue |
| Blunt | Pushes soft tissue aside instead of cutting | Friable liver or kidney |
Chapter 3
Surgical Procedures
Key takeaways
- The submucosa is the strongest layer of the bowel wall and must be in every anastomosis bite, and the ureter runs under the uterine artery near the cervix. → Anatomy the scrub must know: abdominal wall, bowel, pelvis and groin
- Screw placement in a plated fracture runs drill, measure with the depth gauge, tap, then insert. → The instrument each step calls for
- Before the scope goes in, white balance, focus and warm the lens; robotic instruments are advanced only under the surgeon's view. → Endoscopic, robotic, stapled and eye procedure steps
- A monopolar resectoscope needs a nonelectrolytic irrigant such as glycine or sorbitol, and a frozen section leaves the field dry with no preservative. → Incisions, irrigants, specimens, vascular suture and graft dressings
- In a crisis the scrub stays sterile and useful: suction and a folded lap sponge for sudden bleeding, a covered and protected field during malignant hyperthermia. → Emergencies at the field: conversion, hemorrhage and malignant hyperthermia
Common trap
- Direct and indirect are easy to reverse. Anchor on the inferior epigastric vessels: medial means direct, lateral means indirect. → Anatomy the scrub must know: abdominal wall, bowel, pelvis and groin
- In stapled bowel questions, a circular stapler, a skin stapler or a clip applier is the usual distractor. After a cutting stapler joins two limbs side to side, the next need is to close the common opening. → Endoscopic, robotic, stapled and eye procedure steps
- During sudden bleeding, stepping back to give the surgeon room, or handing the electrosurgical pencil, can sound helpful. Neither controls a torn major vessel; pressure and a clear view come first. → Emergencies at the field: conversion, hemorrhage and malignant hyperthermia
Quick reference
| Step | What to pass |
|---|---|
| Clamping uterine and cardinal ligament pedicles | Heaney clamp, with a tooth at the tip |
| Drawing a tie behind the cystic duct | Right-angle clamp |
| Spreading ribs in a thoracotomy | Self-retaining rib spreader |
| Removing lamina over a nerve root | Kerrison-type rongeur with a thin footplate |
| Incising the scalp flap | Scalp clips on an applier |
| Situation | Choice | Reason |
|---|---|---|
| Cesarean uterine incision | Transverse, lower uterine segment | Bleeds less, stronger scar, lower later rupture risk |
| Monopolar transurethral resection | Glycine or sorbitol | Nonconductive; saline would disperse the current, and water is hemolytic |
| Frozen section | Dry labeled container, no preservative | Formalin fixes tissue and blocks a fast diagnosis |
| Graft to femoral artery | Double-armed monofilament nonabsorbable suture on taper needles | Permanent, smooth, no wicking, spreads the wall |
| Split-thickness skin graft | Tie-over bolster | Keeps the graft against its bed while vessels grow in |
Chapter 4
Patient Safety & Counts
Key takeaways
- Any mismatch during the time out stops the case until it is resolved, and the site is marked by the person who will operate, with the patient awake and involved. → Right patient, right site, right drug, right specimen
- Sponges and sharps are counted at four points and instruments at two routine points, plus a count at any permanent relief of the scrub or circulator, aloud and together by the technologist and the circulator. → Surgical counts: when, what and how
- When a count is wrong, the surgeon is told first, and if the item is not found an x-ray is taken and read by a radiologist before the wound is closed. → When the count is wrong or cannot be done
- Keep the arm under 90 degrees with the palm up, pad the fibular head in lithotomy, and clip hair close to the time of surgery. → Positioning injuries, hair removal and prep pooling
- Rising end-tidal carbon dioxide is the earliest sign of malignant hyperthermia, and a fire on the patient is fought by stopping the gases and removing the burning material. → Electrosurgery, fire, lasers, malignant hyperthermia and needlesticks
Common trap
- Do not give instruments the same four-point schedule as sponges, and do not drop the baseline count before incision. Without a baseline, the closing number means nothing. → Surgical counts: when, what and how
- Waiting for a high temperature to suspect malignant hyperthermia is the classic wrong answer. The name describes a late sign; the rising carbon dioxide comes first. → Electrosurgery, fire, lasers, malignant hyperthermia and needlesticks
Quick reference
| Item | When counted |
|---|---|
| Sponges and sharps | Before incision, as peritoneal closure begins, as fascial closure begins, at skin closure, and at any permanent relief of the scrub or circulator |
| Instruments | Before incision and before closure of the body cavity, plus at any permanent relief of the scrub or circulator |
| Position or device | Structure at risk | Protection |
|---|---|---|
| Supine with armboard | Brachial plexus, ulnar nerve | Abduct under 90 degrees, palm up |
| Lithotomy | Common peroneal nerve at the fibular head | Pad stirrups, keep the lateral calf off the post |
| Lateral | Dependent axilla and brachial plexus | Roll just below the axilla, not in it |
Chapter 5
Professional Practice
Key takeaways
- The surgeon explains the procedure and obtains informed consent; a witness signature only confirms who signed and that the signing was voluntary. → Informed consent: who explains, who witnesses, who may sign
- A surgeon's verbal order does not expand a technologist's legal scope, so a task such as injecting a drug, when state law and facility policy do not allow it, is declined calmly. → Roles, scope of practice and owning your errors
- Correct a record with a single line, initials and date, and keep occurrence reports out of the chart. → Documentation: count records, corrections and occurrence reports
- Negligence needs duty, breach, causation and damages; operating beyond the consent is battery; leaving the field without relief is abandonment. → Legal doctrines: negligence, res ipsa loquitur, respondeat superior, battery and abandonment
- A do-not-resuscitate order is reviewed before surgery and continued or suspended in writing, never ignored or assumed void. → Privacy, do-not-resuscitate orders and advance directives
Common trap
- A direct order from the surgeon is not a defense. If a task is outside the technologist's legal scope, the right answer declines it politely and offers a safe way to keep the case moving. → Roles, scope of practice and owning your errors
- Answers that put a copy of the occurrence report in the chart, or note in the chart that one was filed, are wrong. The report stays a separate risk-management document. → Documentation: count records, corrections and occurrence reports
Quick reference
| Doctrine | Defining element | Operating room example |
|---|---|---|
| Negligence | Duty, breach, causation and damages | Care below the accepted standard that harms a patient |
| Res ipsa loquitur | The injury would not happen without negligence | A sponge found on a postoperative x-ray |
| Respondeat superior | Employer answers for employees' acts in their job | Hospital held liable for its technologist's error |
| Battery | Touching without valid consent | Removing a lesion not on the consent |
| Abandonment | Leaving accepted care without handing it over | Walking out of a case with no relief |
Chapter 6
Basic Science
Key takeaways
- The recurrent laryngeal nerve comes from the vagus (CN X), the facial nerve (CN VII) runs through the parotid, and the brachial plexus comes from C5 through T1. → Nerves at risk in the neck, face and arm
- The right lung has 3 lobes and the left has 2, and the left internal thoracic artery is usually grafted to the LAD. → Landmarks in the chest, the eye and the right lower quadrant
- The cystic artery lies in Calot's triangle, and the common bile duct joins the pancreatic duct to form the ampulla of Vater. → The biliary tree: Calot's triangle and the ampulla of Vater
- Controlled entry into the biliary, gut, genital, urinary or respiratory tract is Class II, while existing infection or a perforated viscus is Class IV. → Surgical microbiology: wound classes, healing and prions
- A 1% solution holds 10 mg/mL, plain lidocaine is capped at 4.5 mg/kg, and dantrolene for malignant hyperthermia starts at 2.5 mg/kg. → Drug math: percent solutions, lidocaine limits and dantrolene
Common trap
- Distractors offer neighboring cranial nerve numbers: IX, XI and XII for the laryngeal nerve, or V for the parotid. The larynx belongs to X and facial expression to VII; the trigeminal (V) carries facial sensation, not movement. → Nerves at risk in the neck, face and arm
- Answer choices swap in the wrong duct pair. The ampulla is the common bile duct plus the pancreatic duct; the cystic duct plus the common hepatic duct makes the common bile duct; and the two hepatic ducts make the common hepatic duct. → The biliary tree: Calot's triangle and the ampulla of Vater
- The wrong answers come from three slips: reading 1% as 1 mg/mL instead of 10 mg/mL, using the with-epinephrine limit for plain lidocaine, and mistaking the 10 mg/kg ceiling for the starting dantrolene dose. → Drug math: percent solutions, lidocaine limits and dantrolene
Quick reference
| Class | Meaning |
|---|---|
| I, clean | Does not enter the respiratory, alimentary, genital or urinary tract |
| II, clean-contaminated | Enters one of those tracts, including the biliary tract, under controlled conditions |
| III, contaminated | Fresh accidental wound, major break in technique or gross spillage, no established infection |
| IV, dirty-infected | Existing clinical infection or perforated viscus |