Chapters0/30 ▾
- 1.Asepsis & Sterile Technique0/5
- Where sterile ends: gowns, tables, movement and the prep
- Breaks in technique: strike-through, glove punctures and wound class
- Judging packages, trays and solutions before they reach the field
- Reading sterilization indicators and biological results
- Cleaning first, Spaulding, and choosing a sterilization method
- 2.Instrumentation & Sutures0/5
- 3.Surgical Procedures0/5
- 4.Patient Safety & Counts0/5
- 5.Professional Practice0/5
- Informed consent: who explains, who witnesses, who may sign
- Roles, scope of practice and owning your errors
- Documentation: count records, corrections and occurrence reports
- Legal doctrines: negligence, res ipsa loquitur, respondeat superior, battery and abandonment
- Privacy, do-not-resuscitate orders and advance directives
- 6.Basic Science0/5
Chapter 2 · Lesson 1 of 5
Reading an instrument by its jaws, blades and tip
1 min read
Most instrument questions describe the working end and ask what it is for. The rule behind nearly all of them is simple: the more the tissue must survive and keep working, the gentler the jaw.
Teeth and heavy serrations concentrate force at points, so they belong on tough tissue that will be removed, ligated or closed under tension. Suction tips follow the same idea: fine or angled tips suit shallow or microsurgical fields but clog almost at once in a pool of blood.
| Need | Feature to look for |
|---|---|
| Occlude an artery that must stay healthy | Fine, shallow, atraumatic serrations with light closing pressure |
| Hold a loop of bowel | Broad, smooth, fenestrated jaws that spread the pressure |
| Dissect a delicate plane | Long shanks with short, fine, blunt-tipped curved blades |
| Clear a large pool of fluid | Large-bore rigid suction tip with a guard |
Scissors follow the same logic. Fine dissecting scissors put a small, controlled bite deep in the wound; heavy short-bladed scissors are for dense tissue and suture. Cutting suture with dissecting scissors dulls the fine tips.
Example: the surgeon is working on a femoral artery that must stay open after the clamp comes off. A clamp with interlocking teeth would grip well but would damage the inner lining, where a clot can form, so the atraumatic vascular clamp is the right pass.
Check yourself
1. A vascular clamp is needed to occlude an artery temporarily without injuring the intima. Which jaw design should the scrub technologist pass?
2. The surgeon is dissecting a thin, delicate tissue plane and asks for scissors. Which pair should be passed?
Facts checked 2026-11-15 · Sources: NBSTSA: Surgical Technologist Certifying Examination Content Outline, Association of Surgical Technologists: Standards of Practice
Surgical Technologist (CST) cheat sheet: every key fact on one page →