Chapters0/30 ▾
- 1.Asepsis & Sterile Technique0/5
- Where sterile ends: gowns, tables, movement and the prep
- Breaks in technique: strike-through, glove punctures and wound class
- Judging packages, trays and solutions before they reach the field
- Reading sterilization indicators and biological results
- Cleaning first, Spaulding, and choosing a sterilization method
- 2.Instrumentation & Sutures0/5
- 3.Surgical Procedures0/5
- 4.Patient Safety & Counts0/5
- 5.Professional Practice0/5
- Informed consent: who explains, who witnesses, who may sign
- Roles, scope of practice and owning your errors
- Documentation: count records, corrections and occurrence reports
- Legal doctrines: negligence, res ipsa loquitur, respondeat superior, battery and abandonment
- Privacy, do-not-resuscitate orders and advance directives
- 6.Basic Science0/5
Chapter 1 · Lesson 3 of 5
Judging packages, trays and solutions before they reach the field
1 min read
Before anything is opened, the technologist checks package integrity. Current practice uses event-related sterility: a package stays sterile until something compromises it, such as a tear, moisture, crushing or rough handling.
The calendar does not decide. A package still within its printed date but with a small tear is returned for reprocessing. A commercially prepared item with a manufacturer's expiration date is still pulled once that date passes.
- A dropped package in an impervious wrapper that is intact and dry may be used right away for that case, but it never goes back on the shelf. A woven wrap that hits the floor is reprocessed.
- Ratcheted instruments are processed open. If clamps arrive locked on a ratchet, steam may not have reached the box lock and jaws, so the whole tray is returned.
- Once a sterile solution is opened, whatever is left in the bottle is discarded. The lip and cap are no longer sterile, so it is never recapped for later.
Example: a peel pouch is within date, dry and sealed, but one corner of the seal has lifted. The lifted seal is an event that broke the barrier, so the item is not opened onto the field even though the date is fine.
Check yourself
1. A stored package is still within its printed date, but its wrapper has a small tear. What governs whether it may be used?
2. A tray in an impervious wrapper is dropped on a dry floor; on inspection the wrapper is intact and dry. What is correct?
Facts checked 2026-11-15 · Sources: NBSTSA: Surgical Technologist Certifying Examination Content Outline, CDC/HICPAC: Guideline for Disinfection and Sterilization in Healthcare Facilities, Association of Surgical Technologists: Standards of Practice
Surgical Technologist (CST) cheat sheet: every key fact on one page →