Chapters0/30 ▾
- 1.Asepsis & Sterile Technique0/5
- Where sterile ends: gowns, tables, movement and the prep
- Breaks in technique: strike-through, glove punctures and wound class
- Judging packages, trays and solutions before they reach the field
- Reading sterilization indicators and biological results
- Cleaning first, Spaulding, and choosing a sterilization method
- 2.Instrumentation & Sutures0/5
- 3.Surgical Procedures0/5
- 4.Patient Safety & Counts0/5
- 5.Professional Practice0/5
- Informed consent: who explains, who witnesses, who may sign
- Roles, scope of practice and owning your errors
- Documentation: count records, corrections and occurrence reports
- Legal doctrines: negligence, res ipsa loquitur, respondeat superior, battery and abandonment
- Privacy, do-not-resuscitate orders and advance directives
- 6.Basic Science0/5
Study guide · Chapter 1 of 6
Asepsis & Sterile Technique Study Guide — Surgical Technologist (CST)
39 free practice questions
Sterile technique questions on the CST exam rarely ask for a definition. They describe a moment in the room, such as a towel slipping off a table, a glove tearing or a strip changing color, and ask what that moment means and what the technologist does next. This chapter covers the sterile boundaries, breaks in technique, package integrity, sterilizer monitoring and how a device is matched to a process.
Key takeaways
- A sterile gown is sterile only in front from mid-chest to field level and on the sleeves from the cuff to about two inches above the elbow, and a draped table is sterile only at table-top level.
- Anyone who sees a break in technique names it out loud at once, whoever caused it.
- Sterility is event-related: a tear, moisture or a drop decides whether a package can be used, not the printed date.
- Only a biological indicator proves that a cycle killed spores, so implant loads are held until it is read and a positive result recalls every load back to the last negative one.
- Cleaning always comes first, and the Spaulding class of a device is set by the tissue it will touch.
Lessons in this chapter
5 short lessons · 5 min read
- 1Where sterile ends: gowns, tables, movement and the prep1 min
- 2Breaks in technique: strike-through, glove punctures and wound class1 min
- 3Judging packages, trays and solutions before they reach the field1 min
- 4Reading sterilization indicators and biological results1 min
- 5Cleaning first, Spaulding, and choosing a sterilization method1 min
Facts checked 2026-11-15 · Sources: NBSTSA: Surgical Technologist Certifying Examination Content Outline, CDC/HICPAC: Guideline for Disinfection and Sterilization in Healthcare Facilities, Association of Surgical Technologists: Standards of Practice
Surgical Technologist (CST) cheat sheet: every key fact on one page →Next chapter: Instrumentation & Sutures →Practice tests
Practice questions based on the NBSTSA Certified Surgical Technologist exam content outline, AST standards of practice, and durable operating-room principles. CST is a mark of the National Board of Surgical Technology and Surgical Assisting; this site is not affiliated with or endorsed by NBSTSA or AST. Surgical counts, documentation, and what a technologist may perform are governed by your facility's policy and by state law, and sterilization parameters follow the manufacturer's written instructions — confirm all of these locally rather than from a practice test, and confirm current eligibility and exam requirements with the certifying board. About the CST exam →