Chapters0/30 ▾
- 1.Asepsis & Sterile Technique0/5
- Where sterile ends: gowns, tables, movement and the prep
- Breaks in technique: strike-through, glove punctures and wound class
- Judging packages, trays and solutions before they reach the field
- Reading sterilization indicators and biological results
- Cleaning first, Spaulding, and choosing a sterilization method
- 2.Instrumentation & Sutures0/5
- 3.Surgical Procedures0/5
- 4.Patient Safety & Counts0/5
- 5.Professional Practice0/5
- Informed consent: who explains, who witnesses, who may sign
- Roles, scope of practice and owning your errors
- Documentation: count records, corrections and occurrence reports
- Legal doctrines: negligence, res ipsa loquitur, respondeat superior, battery and abandonment
- Privacy, do-not-resuscitate orders and advance directives
- 6.Basic Science0/5
Chapter 1 · Lesson 5 of 5
Cleaning first, Spaulding, and choosing a sterilization method
1 min read
No sterilizer can make up for dirt. Dried blood and other organic soil shield microorganisms from the sterilant, so cleaning always comes before disinfection or sterilization.
A longer cycle or a soak in disinfectant does not fix a soiled lumen; it has to be cleaned first. Keeping soil moist at the point of use stops it from drying in the first place.
| Spaulding class | Tissue contacted | Minimum processing |
|---|---|---|
| Critical | Sterile tissue or the vascular system | Sterilization |
| Semicritical | Mucous membranes or non-intact skin | Sterilization or at least high-level disinfection |
| Noncritical | Intact skin | Low-level disinfection |
Steam is the method of choice only for items that tolerate heat and moisture. A heat- and moisture-sensitive device goes to a low-temperature method such as hydrogen peroxide gas plasma or ethylene oxide. Alcohol is not sporicidal, so it never sterilizes.
Immediate-use steam sterilization is for a genuine urgent need; it does not replace terminal sterilization, is not a fix for short inventory and is not the routine route for implants. Example: a laryngoscope blade touches the mucous membrane of the airway, so it is semicritical.
Check yourself
1. Under the Spaulding classification, how is a laryngoscope blade that contacts mucous membranes categorized?
2. A flexible, heat- and moisture-sensitive lumened device requires sterilization. Which method is indicated?
Facts checked 2026-11-15 · Sources: NBSTSA: Surgical Technologist Certifying Examination Content Outline, CDC/HICPAC: Guideline for Disinfection and Sterilization in Healthcare Facilities, Association of Surgical Technologists: Standards of Practice
Surgical Technologist (CST) cheat sheet: every key fact on one page →