28 Water Supply, Hose, Streams & Extinguishers Practice Questions & Answers
Every Water Supply, Hose, Streams & Extinguishers practice question from the Firefighter I & II Certification Practice Test, with the correct answer and a short explanation.
Start practice test →1. During a hydrant flow test, a cap gauge on the test hydrant reads 72 psi with no water moving and 58 psi while a nearby hydrant flows. What does the 58 psi reading represent?
- A.Residual pressure✓ Answer
- B.Velocity pressure
- C.Elevation pressure
- D.Static pressure
Static pressure is measured with no water flowing, which is the 72 psi reading. The pressure that remains in the system while water is flowing is residual pressure, so the 58 psi reading is residual. Velocity (flow) pressure is the forward pressure of a stream read with a pitot gauge at an open outlet, not on a capped one, and elevation pressure relates to height, not to flow.
Ref QB-SB4EDCSource: NFPA 1010 (2024) Ch. 7, Fire Fighter II — hydrant flow testing; NFPA 291 — fire flow testing (static, residual and pitot pressures)Report a problem with this question
2. An engine is pumping from a hydrant, and the operator watches the intake gauge fall as more lines are opened. Below about what residual pressure should the operator stop increasing flow to protect the water system?
- A.5 psi
- B.20 psi✓ Answer
- C.80 psi
- D.50 psi
Keeping at least about 20 psi of residual pressure in the main protects the distribution system: going lower can collapse or damage the main, let contaminants be drawn back into the drinking water, and starve other users and the pump itself. 5 psi is far too low, while 50 and 80 psi are nozzle operating pressures, not the residual minimum.
Ref QB-8UJWMASource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — water supply; 20 psi minimum residual pressure (NFPA 291 fire flow testing basis)Report a problem with this question
3. In a city with freezing winters, a firefighter opens a dry-barrel hydrant only partway to limit the flow. What problem can this cause?
- A.The main valve freezes shut below the frost line
- B.Water escapes through the drain and erodes the soil✓ Answer
- C.Air is pulled into the main and contaminates it
- D.The outlet caps blow off from trapped pressure
A dry-barrel hydrant's drain stays open whenever the main valve is not fully open, so a partly open hydrant forces pressurized water out the drain and can wash out the soil supporting the hydrant. Dry-barrel hydrants are opened fully and the flow is controlled with a gate valve, and they are opened and closed slowly to prevent water hammer.
Ref QB-RBR38BSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — water supply; dry-barrel hydrant operation (open fully, drain valve)Report a problem with this question
4. A hydrant's bonnet and caps are painted green under the NFPA hydrant color-coding system. What rated flow does this indicate?
- A.1,500 gpm or more
- B.Less than 500 gpm
- C.500 to 999 gpm
- D.1,000 to 1,499 gpm✓ Answer
The NFPA hydrant marking system colors bonnets by rated capacity: light blue (Class AA) is 1,500 gpm or more, green (Class A) is 1,000 to 1,499 gpm, orange (Class B) is 500 to 999 gpm, and red (Class C) is under 500 gpm. The color tells an engine crew at a glance how much water to expect.
Ref QB-BUMW5ESource: NFPA 291 — Recommended Practice for Fire Flow Testing and Marking of Hydrants (bonnet color classes)Report a problem with this question
5. An engine will draft water from a farm pond with no hydrant nearby. Which hose belongs between the pond and the pump intake?
- A.4-inch supply hose
- B.Rubber booster hose
- C.Soft sleeve hose
- D.Hard suction hose✓ Answer
Drafting creates a partial vacuum in the intake hose, so the hose must be stiff enough not to collapse; that is hard suction (hard intake) hose. Soft sleeve hose is meant for a pressurized source such as a hydrant and would flatten under vacuum, and ordinary supply hose and booster hose are not built for vacuum intake.
Ref QB-UBT3RESource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — water supply from static sources (drafting with hard intake hose)Report a problem with this question
6. An engine stops at a hydrant, a firefighter wraps the supply line around it, and the engine drives to the burning house laying hose behind it. Which lay is this, and where does the engine end up?
- A.Forward lay; the engine stays at the fire✓ Answer
- B.Forward lay; the engine stays at the hydrant
- C.Reverse lay; the engine stays at the fire
- D.Reverse lay; the engine stays at the hydrant
In a forward lay hose runs from the water source toward the fire, so the attack engine ends up at the scene with its tools, attack hose and pump available. In a reverse lay the engine stops at the fire first and then lays back to the hydrant, so it ends up at the water source.
Ref QB-AU9KYCSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — water supply; supply hose lays (forward, reverse, split)Report a problem with this question
7. Which supply hose load has fewer sharp bends in the hose but is hard to load and can let several folds spill out together during deployment?
- A.Horseshoe load✓ Answer
- B.Flat load
- C.Accordion load
- D.Minuteman load
The horseshoe load stands hose on edge in a U shape around the bed, which avoids many sharp bends, but it is hard to load and folds can pull out together and tangle. The flat load is the easiest to load and deploys cleanly, the accordion load is easy to shoulder but has many sharp folds, and the minuteman load is a preconnected attack-line load.
Ref QB-TBFRJDSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — hose loads and finishesReport a problem with this question
8. Two 2.5-inch supply lines reach an engine that has only one open intake. Which appliance combines them into a single line?
- A.Water thief
- B.Gated wye
- C.Siamese✓ Answer
- D.Reducer
A siamese merges two or more hoselines into one, so it lets two supply lines feed a single intake. A wye (gated or not) and a water thief do the opposite, splitting one line into several, and a reducer only changes the coupling size.
Ref QB-DUBKGGSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — hose appliances (siamese vs. wye)Report a problem with this question
9. A firefighter rolls a clean, dry hose section for storage, starting at the male coupling so that it ends up in the center of the roll. Which roll is this?
- A.Twin donut
- B.Donut roll
- C.Accordion fold
- D.Straight roll✓ Answer
In the straight roll the hose is rolled from the male end, so the male threads are protected in the center and the female coupling is on the outside, which suits storage and transport. Donut and twin donut rolls start from a fold so that both couplings end up on the outside for quick use, and an accordion fold is not a roll.
Ref QB-WBHR3HSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — hose handling (hose rolls)Report a problem with this question
10. A department's 5-inch supply hose uses Storz couplings. What sets these couplings apart from threaded couplings?
- A.They need a double-male adapter to connect
- B.They are sexless, with no male or female end✓ Answer
- C.They are used only on hard suction hose
- D.They use a Higbee cut to start the threads
Storz couplings are sexless (non-threaded): both halves are identical, with lugs and ramps that lock with a quarter turn, which is why they are common on large-diameter hose. The Higbee cut and male and female ends belong to threaded couplings, and a double-male adapter is needed only when two threaded male ends meet.
Ref QB-FKPPRVSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — fire hose couplings; NFPA 1963 (now part of NFPA 1960) — fire hose connectionsReport a problem with this question
11. On a threaded hose coupling, what is the purpose of the Higbee indicator notch on the lug?
- A.It marks where the thread starts, for alignment✓ Answer
- B.It shows the hose passed its annual service test
- C.It marks the hose diameter and year of manufacture
- D.It shows which way to turn the swivel to tighten
The Higbee cut is a blunted start of the thread that keeps couplings from cross-threading, and the indicator on the lug lines up with it so firefighters can match the thread starts of the male and female couplings, even by feel in smoke or darkness. Service-test status is shown by test records and markings, not by this notch.
Ref QB-X3HH6VSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — fire hose couplings (Higbee cut and indicator)Report a problem with this question
12. A cotton-jacketed hose section was stored while still wet and now shows mold and mildew. Which type of hose damage is this?
- A.Organic damage✓ Answer
- B.Chemical damage
- C.Mechanical damage
- D.Thermal damage
Mold and mildew are living organisms that feed on natural fibers such as cotton, so they cause organic damage; drying hose completely before storing it prevents this. Chemical damage comes from substances such as petroleum products or battery acid, thermal damage from heat, and mechanical damage from abrasion, cuts and crushing.
Ref QB-GK22XWSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — hose care and maintenance (causes of hose damage)Report a problem with this question
13. Under the NFPA hose care and service-testing standard, how often must in-service fire hose be service-tested?
- A.Every five years when the apparatus is tested
- B.Each month during the apparatus inspection
- C.At least once a year and after any repair✓ Answer
- D.Only after it is damaged during an incident
Pressure testing every year, and again after a repair, finds weak jackets, slipping couplings and liner defects before the hose fails at a fire; results are recorded and failed hose is marked and removed from service. Waiting for visible damage misses hidden defects, five years is far too long, and the monthly apparatus check is a visual inspection, not a pressure test.
Ref QB-Y3VUBWSource: NFPA 1962 care and service testing of fire hose (consolidated into NFPA 1930, 2025 edition) — annual service testingReport a problem with this question
14. An engine operator is supplying a handline equipped with a smooth-bore nozzle. What nozzle pressure is generally recommended?
- A.80 psi
- B.100 psi
- C.150 psi
- D.50 psi✓ Answer
Smooth-bore handline nozzles are designed to work at about 50 psi, which gives good reach and penetration with a nozzle reaction a crew can control. About 80 psi is used for smooth-bore master streams, 100 psi is the standard fog nozzle pressure, and 150 psi would create excessive reaction on a handline.
Ref QB-HKDC4YSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — fire streams; standard nozzle operating pressures (smooth bore 50 psi, master stream 80 psi, fog 100 psi)Report a problem with this question
15. A crew applies a fog stream into a closed, superheated room. About how much does water expand when it turns to steam at 212°F (100°C)?
- A.About 17,000 times
- B.About 1,700 times✓ Answer
- C.About 170 times
- D.About 17 times
At 212°F (100°C) water turns to steam and expands roughly 1,700 times in volume. That expansion displaces oxygen and helps smother the fire, but in a closed space it can also upset the thermal layer and push scalding steam onto crews and victims, which is why fog application must be controlled.
Ref QB-Z387HXSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — fire streams; extinguishing properties of water (approx. 1,700:1 steam expansion)Report a problem with this question
16. The flow through a hoseline is doubled while the hose diameter and length stay the same. About what happens to friction loss?
- A.It is cut about in half
- B.It roughly quadruples✓ Answer
- C.It stays about the same
- D.It roughly doubles
Friction loss varies roughly with the square of the flow, so doubling the flow (2 squared) produces about four times the friction loss. Doubling the hose length, by contrast, only doubles the loss, and friction loss is largely independent of the pressure in the hose.
Ref QB-JKRP9ZSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — fire streams; friction loss principles (loss varies with the square of flow)Report a problem with this question
17. A nozzle team is working 50 feet above the pump. Ignoring friction loss, about how much extra pressure must the pump supply to overcome the elevation?
- A.100 psi
- B.25 psi✓ Answer
- C.5 psi
- D.50 psi
A column of water exerts about 0.434 psi per foot of height, rounded to 0.5 psi per foot on the fireground, so 50 feet of elevation needs about 25 psi more. The shortcut of about 5 psi per story gives the same estimate in multistory buildings, while 1 psi per foot doubles the real value.
Ref QB-24KHPYSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — fire streams; elevation pressure (about 0.5 psi per foot / 5 psi per story)Report a problem with this question
18. A small fire starts inside an energized electrical panel in a workshop. Which portable extinguisher is the best choice?
- A.CO2 extinguisher✓ Answer
- B.Water extinguisher
- C.Class K extinguisher
- D.AFFF extinguisher
Energized electrical equipment is a Class C hazard, so the agent must not conduct electricity; carbon dioxide is nonconductive and leaves no residue on the equipment. Water and AFFF are water-based and can carry current back to the operator, and a Class K wet chemical unit is meant for cooking-oil fires.
Ref QB-BK9C3RSource: NFPA 10 — Standard for Portable Fire Extinguishers (Class C hazards, nonconductive agents); NFPA 1010 (2024) Ch. 6, Fire Fighter I — portable extinguishersReport a problem with this question
19. Magnesium shavings ignite on a machine-shop floor. Which extinguishing agent is designed for this fire?
- A.Pressurized water
- B.Carbon dioxide
- C.ABC dry chemical
- D.Class D dry powder✓ Answer
Burning combustible metals are Class D fires and need a dry powder agent, such as a sodium chloride or graphite-based powder, that smothers the metal and absorbs heat. Dry powder is not the same as dry chemical: ABC dry chemical is not rated for metals, carbon dioxide can react with burning magnesium, and water can cause a violent reaction.
Ref QB-T347GQSource: NFPA 10 — Standard for Portable Fire Extinguishers (Class D combustible metals, dry powder agents)Report a problem with this question
20. A deep-fryer fire is attacked with a Class K wet chemical extinguisher after the kitchen hood system discharges. How does the agent mainly work?
- A.It dilutes the oil so it can no longer ignite
- B.It interrupts the chain reaction like halon does
- C.It turns the oil surface into a soapy foam layer✓ Answer
- D.It displaces the oxygen like carbon dioxide does
Wet chemical agents, usually potassium acetate solutions, react with hot cooking fat in a process called saponification, forming a soapy foam blanket that seals the surface while the mist helps cool the oil. Because that blanket prevents reignition, Class K units back up the fixed hood suppression system.
Ref QB-4BYT65Source: NFPA 10 — Standard for Portable Fire Extinguishers (Class K wet chemical, saponification; use after hood system)Report a problem with this question
21. Using the PASS method on a small trash-can fire, where should the firefighter aim the extinguisher nozzle?
- A.At the top of the flames
- B.Into the smoke above it
- C.At the base of the fire✓ Answer
- D.At the middle of the flames
PASS stands for Pull the pin, Aim at the base of the fire, Squeeze the handle and Sweep side to side. Aiming at the base puts the agent on the burning fuel itself; spraying the flames or the smoke mostly wastes the limited agent and leaves the fuel burning.
Ref QB-MT5ZR5Source: NFPA 1010 (2024) Ch. 6, Fire Fighter I — extinguishing incipient fires with portable extinguishers (PASS method)Report a problem with this question
22. A portable extinguisher is labeled 2-A:10-B:C. What does the number 10 in the B rating indicate?
- A.Seconds of agent discharge with the handle held
- B.Gallons of water that the agent is equivalent to
- C.Square feet of liquid fire a non-expert can put out✓ Answer
- D.Feet of stream reach the extinguisher can achieve
For Class B, the number is the approximate area in square feet of flammable-liquid fire that a non-expert operator can extinguish, so a 10-B unit handles about 10 square feet. Water equivalency belongs to the A rating (each 1-A is about 1.25 gallons of water), and the C carries no number because it only shows the agent does not conduct electricity.
Ref QB-5BB6C6Source: NFPA 10 — Standard for Portable Fire Extinguishers (extinguisher classification and rating; UL/ANSI 711 rating basis)Report a problem with this question
23. At a rural house fire with no hydrants, water tenders are hauling water. A firefighter sets up a fold-a-tank beside the attack engine. What is the main reason for this setup?
- A.The tank adds pressure to the engine's intake line
- B.The engine no longer needs hard suction hose
- C.Tenders can unload quickly and go back to refill✓ Answer
- D.Tenders can pump straight into the attack lines
In a tender shuttle, the portable tank is set up near the attack (or supply) engine so each tender can drop its whole load in one dump and head straight back to the fill site, while the engine drafts continuously from the tank. The tank is open to the air, so it adds no pressure; the engine still needs hard suction hose to draft from it; and a tender pumping directly into attack lines would be tied up at the scene instead of shuttling.
Ref QB-NTGBX6Source: Wikipedia, 'Portable water tank' (Usage/deployment: carried on water tenders, set up near the attack engine during a shuttle so tenders drop their load and return to the fill site; engine drafts with suction hose)Report a problem with this question
24. A rural fire district has a dry hydrant installed at a farm pond. When an engine arrives at this hydrant, how does it get water?
- A.It drafts through the pipe after priming the pump✓ Answer
- B.It opens the main valve to use the pond's pressure
- C.It connects soft supply hose to the hydrant outlet
- D.It waits for the hydrant's built-in pump to start
A dry hydrant is an unpressurized, permanently installed pipe with one end (usually fitted with a strainer) below the water surface and the other end above ground with a hard-sleeve connection. The engine connects hard suction hose, the primer evacuates the air, and atmospheric pressure then pushes water up into the pump. There is no main valve or pressure to tap, no built-in pump, and soft supply hose would collapse under the vacuum of drafting.
Ref QB-6BPGH7Source: Wikipedia, 'Fire hydrant' — section 'Non-pressurized (dry) Hydrants' (unpressurized permanent pipe with strainer below water; pumper drafts after vacuuming air out with a primer)Report a problem with this question
25. An engine is drafting from a pond, and its primer has removed the air from the hard suction hose. What actually forces the water up the hose and into the pump?
- A.Suction pulling directly on the water column
- B.Atmospheric pressure on the water surface✓ Answer
- C.The weight of the water in the pump casing
- D.Residual pressure from the nearest water main
Drafting works by creating a partial vacuum at the pump intake; the atmospheric pressure (about 14.7 psi at sea level) acting on the open water surface then pushes water up into the pump. A vacuum cannot pull on water, which is why even a perfect vacuum can lift water only about 34 feet in theory, and fire pumps manage roughly 20 to 33 feet in practice. A static source has no connection to a water main, and water already in the pump does not draw more in.
Ref QB-PTUN48Source: Wikipedia, 'Drafting (firefighting)' (partial vacuum; atmospheric pressure on the water surface forces water into the pump; 14.7 psi gives a theoretical maximum lift of 34 ft; practical lifts 20 to 33 ft)Report a problem with this question
26. The only water source for a rural barn fire is a lake 3,000 feet away. Friction loss over that distance is more than a single engine can overcome. Which operation addresses this problem?
- A.Split hose lay
- B.Reverse hose lay
- C.Forward hose lay
- D.Relay pumping✓ Answer
In relay pumping, an engine drafts at the source and pumps into supply hose, and one or more additional engines placed along the line each take in that water and boost its pressure before sending it on, so friction loss is overcome in stages over a long distance. Forward, reverse and split lays only describe how one or two engines lay hose between a hydrant and the fire; none adds pumping capacity along a very long line.
Ref QB-7B2UP8Source: Wikipedia, 'Fire hose' (supply and relay hoses used to relay water from one pumper to another over a long distance); Wikipedia, 'Drafting (firefighting)' (multiple relays with a drafting pump discharging at great distances)Report a problem with this question
27. A gasoline spill is burning as a pool on flat, open pavement, with no wall, vehicle or other object nearby. Which Class B foam application method should the nozzle operator use?
- A.Roll-on, aimed at the ground in front of the spill✓ Answer
- B.Bank-down, aimed at the pavement behind the spill
- C.Rain-down, lofted high so foam falls on the fire
- D.Plunge, aimed straight into the center of the fuel
The roll-on (sweep) method is the one meant for a pool of flammable liquid on open ground: the stream hits the ground just in front of the spill and the foam rolls gently across the surface to form a blanket. Bank-down needs a vertical object to deflect the stream, which this scene lacks, and rain-down is the fallback when neither of the other two can be used and is easily disrupted by wind. Driving foam straight into the fuel breaks the blanket and splashes burning liquid, while foam must be applied as gently as possible.
Ref QB-QT7Z99Source: Wikipedia, 'Firefighting foam' — Application techniques (sweep/roll-on for a pool on open ground; bankshot needs a vertical object; raindown when the other two cannot be used; apply as gently as possible)Report a problem with this question
28. A portable extinguisher's label reads 4-A:60-B:C. About how much water is its Class A rating equivalent to?
- A.About 4 gallons of water
- B.About 2.5 gallons of water
- C.About 5 gallons of water✓ Answer
- D.About 60 gallons of water
Under the UL 711 rating system, the number in front of the A is multiplied by 1.25 to give the equivalent extinguishing capability in gallons of water, so 4-A equals about 4 x 1.25 = 5 gallons. Reading the number as gallons directly ignores the 1.25 factor, 2.5 gallons is simply the size of a common water extinguisher, and 60 belongs to the B rating, which is an area in square feet, not a water volume.
Ref QB-8BD6V9Source: Wikipedia, 'Fire extinguisher' — US rating under ANSI/UL 711 (number before A x 1.25 = equivalent gallons of water; number before B = square feet)Report a problem with this question
Other topics in this exam
Original practice questions written to the job performance requirements of NFPA 1010 (2024), which replaced NFPA 1001 for Fire Fighter I and II, and NFPA 470 for hazardous materials Awareness and Operations. Not affiliated with or endorsed by NFPA, IFSAC, the Pro Board, or any state fire academy. Each state writes its own certification exam — check your state's fire academy or certification office for its format and which edition it tests. NFPA 1010 standard →