Quibank app: now on the App Store — free, works offline. Get the app ↗

20 Search & Rescue and Ventilation Practice Questions & Answers

Every Search & Rescue and Ventilation practice question from the Firefighter I & II Certification Practice Test, with the correct answer and a short explanation.

Start practice test →
  1. 1. During a working house fire, the first-arriving crew begins searching bedrooms while the engine company stretches a line to the fire. Which description best fits this primary search?

    • A.A visual check from doorways made before entry
    • B.A full room-by-room sweep made only after ventilation
    • C.A slow, detailed sweep made after the fire is out
    • D.A rapid but thorough sweep made during suppression✓ Answer

    The primary search is a quick but thorough search for live victims, made before or during fire suppression, often in poor conditions, because survival time is short. The slow, meticulous search after control and ventilation is the secondary search. A doorway glance misses victims, and waiting for ventilation to finish wastes the time victims have left.

    Ref QB-Q7523YSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — search and rescue JPR (primary search)Report a problem with this question

  2. 2. Fire is in the first-floor kitchen of a two-story home, and the occupants' locations are unknown. Where should the primary search begin?

    • A.Rooms nearest the front door on the first floor
    • B.The basement directly below the kitchen fire
    • C.Rooms nearest the fire on the fire floor✓ Answer
    • D.Bedrooms on the top floor where smoke collects

    Search priority starts with the area most threatened, which is closest to the fire on the fire floor, then moves to the floor directly above and then the top floor where heat and smoke collect. Working from near the fire back toward the exit keeps unsearched areas behind the crew and the exit ahead of them.

    Ref QB-8QA7NYSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — search and rescue JPR; IFSTA search prioritiesReport a problem with this question

  3. 3. After the fire is knocked down and the building is ventilated, the officer orders a secondary search. Which description fits it?

    • A.A quick sweep covering only rooms not yet searched
    • B.A slow, methodical search, ideally by another crew✓ Answer
    • C.A rapid repeat search by the crew that did the primary
    • D.A search done only if victims were found earlier

    The secondary search comes after fire control and ventilation, when conditions allow a slow, meticulous check of every area to find anyone the primary search missed. A fresh crew is preferred because new eyes are less likely to repeat the first crew's misses. It is always done, whether or not victims were found during the primary.

    Ref QB-R7GC8ZSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — search and rescue JPR (secondary search)Report a problem with this question

  4. 4. A truck crew uses an oriented search in a large smoky bedroom. Which arrangement correctly describes this method?

    • A.Each member searches a separate room with no anchor
    • B.One member anchors at the door while others sweep✓ Answer
    • C.The officer sweeps the room while others wait outside
    • D.All members sweep the room together in a single line

    In an oriented search, one firefighter, often the officer, stays at the doorway or a fixed point as the anchor and keeps voice or tether contact while the others sweep the room with tools. The anchor keeps the whole team oriented to the way out, which a single line or separated searchers without an anchor cannot do.

    Ref QB-5Q875VSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — search and rescue JPR (oriented search)Report a problem with this question

  5. 5. While searching, a firefighter becomes separated in heavy smoke, finds a hoseline, and feels along it to a coupling. Which way along the hose leads toward the exit?

    • A.Either way, since couplings give no clue
    • B.Toward whichever end of the hose feels warmer
    • C.Toward the side with the male coupling
    • D.Toward the side with the female coupling✓ Answer

    Hose is laid with the male end of each section pointing toward the nozzle, so the female side leads back toward the water source and the way out. Following warmth leads toward the fire, and the coupling does give a reliable direction.

    Ref QB-N7ECQVSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — search and rescue JPR (maintaining orientation by hoseline)Report a problem with this question

  6. 6. A lone firefighter must move an unconscious adult down an interior stairway to escape heavy smoke. Which technique best fits this situation?

    • A.A chair carry using a nearby kitchen chair
    • B.A cradle-in-arms carry, walking upright
    • C.An extremities carry, lifting by the limbs
    • D.An incline drag, backing down the stairs✓ Answer

    The incline drag lets one rescuer support the victim's head and upper body while backing down the stairs, keeping both people low and moving quickly. The cradle-in-arms carry suits children or small adults and raises the rescuer into the heat, while the chair and extremities carries require two rescuers.

    Ref QB-6QKHAWSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — search and rescue JPR (victim drags and carries)Report a problem with this question

  7. 7. A firefighter in full PPE and SCBA collapses in a hallway, and a partner must move the victim quickly toward the exit. Which method is most appropriate?

    • A.Pull using the drag rescue device built into the coat✓ Answer
    • B.Pull by the cylinder valve and regulator hose
    • C.Remove the SCBA, then lift in a cradle carry
    • D.Lift upright and walk out by the shoulders

    Structural turnout coats contain a built-in drag rescue device designed to let a rescuer drag a downed firefighter low and fast without removing gear. Taking off the SCBA cuts off the victim's air, standing the victim up exposes both to heat, and pulling on the valve or regulator hose can damage the victim's air supply.

    Ref QB-P7SPVWSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — search and rescue JPR (removing a downed firefighter); NFPA 1971/1970 drag rescue deviceReport a problem with this question

  8. 8. A firefighter performing VEIS clears a bedroom window, sounds the floor, and climbs over the sill. What should be the very next action?

    • A.Close the bedroom's interior door✓ Answer
    • B.Search the bed closest to the window
    • C.Open the bedroom door to check the hall
    • D.Break a second window for cross-flow

    Isolate comes before Search: the opened window has just created a new opening, so the room's door must be closed at once to cut the room off from the fire's flow path. Searching first, opening the door, or adding another opening lets heat and fire be drawn toward the room and the firefighter.

    Ref QB-3QHHSSSource: UL FSRI — VEIS and door control research; NFPA 1010 (2024) Ch. 6, Fire Fighter I — search and rescue JPRReport a problem with this question

  9. 9. UL FSRI research is cited to explain why VEIS crews close the room's door quickly after entering. What does closing the door accomplish?

    • A.It removes the room from the fire's flow path✓ Answer
    • B.It marks the room as searched for later crews
    • C.It lets interior fans pull smoke out faster
    • D.It stops smoke from leaving by the vented window

    With the window open and the door open, the room becomes an exhaust point between the fire and the outside, drawing heat and fire into it. Closing the door separates the room from that flow path, and FSRI testing found rooms behind closed doors stayed far more survivable for occupants.

    Ref QB-K7QPCTSource: UL FSRI — closed-door survivability and VEIS isolation researchReport a problem with this question

  10. 10. At a ventilation-limited room-and-contents fire, a crew opens the front door and several windows before any hoseline is ready. What is the most likely result?

    • A.Temperatures drop as the heat escapes outside
    • B.The fire grows rapidly as fresh air reaches it✓ Answer
    • C.Smoke lifts and conditions inside stay stable
    • D.The fire dims as smoke is drawn away from it

    Fires in modern synthetic contents quickly become limited by oxygen, not fuel. New openings supply that oxygen, and UL FSRI tests showed the heat-release rate climbing rapidly, often within a minute or two, unless water was applied. That is why ventilation must be coordinated with suppression rather than done early on its own.

    Ref QB-MRFX2BSource: UL FSRI — ventilation-limited fire and horizontal/vertical ventilation studiesReport a problem with this question

  11. 11. A flow path has formed from an open front door, through a burning living room, to a failed rear window. Where is the most dangerous place for firefighters to operate?

    • A.Outside the house, beside the front door
    • B.In a closed room off the front hall
    • C.Between the fire and the rear window✓ Answer
    • D.Between the front door and the fire

    Heat and smoke travel from high pressure to low pressure: in through the intake, through the fire, and out the exhaust. Everything between the fire and the exhaust opening carries the hottest gases and moving fire, so crews must never operate there; the intake side and isolated rooms are far less exposed.

    Ref QB-49ASFASource: UL FSRI — flow path research; NFPA 1010 (2024) Ch. 6, Fire Fighter I — ventilation JPRReport a problem with this question

  12. 12. Arriving crews see smoke puffing in and out around a closed garage door, smoke-stained windows, and little visible flame. What should happen before anyone enters?

    • A.Set up PPV at the main entry and start it
    • B.Ventilate vertically, as high as possible✓ Answer
    • C.Force the side door and make a fast entry
    • D.Open a ground-level window to relieve heat

    Pulsing smoke, stained windows, and little flame point to an oxygen-starved fire holding hot, fuel-rich gases, the setup for a backdraft. Letting air in at a low level, through a door, window, or fan, can ignite those gases explosively, so the space is opened vertically at its highest point first to release them upward.

    Ref QB-KR4MV9Source: NFPA 1010 (2024) Ch. 6, Fire Fighter I — ventilation JPR; backdraft indicators (fire behavior)Report a problem with this question

  13. 13. Crews plan natural horizontal ventilation of a smoke-filled single-story house with a steady wind from the west. Which sequence is correct?

    • A.Open the leeward (east) side first, then the windward side✓ Answer
    • B.Open the windward (west) side first, then the leeward side
    • C.Open both sides at the same moment for full cross-flow
    • D.Open only the windward side so wind pushes smoke out

    The exhaust opening is made first on the downwind side so smoke and heat have somewhere to go; then the upwind intake is opened and the wind drives products out through it. Opening the windward side first, or only, lets wind pressurize the building and drive smoke and fire deeper inside.

    Ref QB-39XEA9Source: NFPA 1010 (2024) Ch. 6, Fire Fighter I — horizontal ventilation JPRReport a problem with this question

  14. 14. An engine crew is about to start a positive-pressure ventilation (PPV) fan at the front door of a house fire. What must be in place before the fan is turned on?

    • A.An exhaust opening created near the fire✓ Answer
    • B.The fan placed just inside the doorway
    • C.Interior doors opened throughout the house
    • D.All windows closed so pressure can build

    PPV raises pressure inside the building, so there must already be an exhaust opening near the fire, roughly as large as the intake or larger, or the pressure drives heat and smoke into uninvolved areas. The fan sits outside the door so its cone of air covers the whole doorway, and the fire must be located with a line ready.

    Ref QB-JRR9Q8Source: NFPA 1010 (2024) Ch. 6, Fire Fighter I — horizontal (mechanical) ventilation JPR; IFSTA PPV guidanceReport a problem with this question

  15. 15. A nozzle operator inside a room uses hydraulic ventilation to clear smoke out a window after the fire is knocked down. How should the stream be set up?

    • A.Fog nearly filling the window, nozzle a bit back✓ Answer
    • B.Fog wider than the window, nozzle at the sill
    • C.Nozzle pushed out the window and aimed outside
    • D.Straight stream aimed at the window's center

    A fog pattern covering most of the opening (IFSTA cites about 85 to 90 percent), with the nozzle set back roughly 2 feet, draws a large volume of smoke and air along with the water. A straight stream entrains little air, a pattern wider than the window strikes the frame and lets air back in, and a nozzle outside the window loses the draw.

    Ref QB-29K458Source: NFPA 1010 (2024) Ch. 6, Fire Fighter I — horizontal (hydraulic) ventilation JPR; IFSTA hydraulic ventilationReport a problem with this question

  16. 16. Fire is confirmed in the attic over the rear bedrooms of a peaked-roof house, and the roof is judged safe to work on. Where should the vertical ventilation opening be made?

    • A.Over the center of the roof, regardless of fire
    • B.Over the front of the house, well away from the fire
    • C.At the eave line nearest the ladder for safety
    • D.As high as safely possible, directly over the fire✓ Answer

    Hot gases rise, so an opening at the highest safe point directly over the fire releases them most efficiently and limits spread. An opening away from the fire pulls fire across unburned areas toward it, and an eave-level hole is too low to exhaust the hottest gases well.

    Ref QB-HRDXH7Source: NFPA 1010 (2024) Ch. 6, Fire Fighter I — vertical ventilation JPRReport a problem with this question

  17. 17. In a long, narrow strip mall with fire spreading through the common cockloft, the officer orders a trench cut. Which statement about this cut is correct?

    • A.It replaces the need for a vent hole over the main fire
    • B.It is made directly over the fire as the first opening
    • C.It is a defensive cut made after venting over the fire✓ Answer
    • D.It is a small inspection hole used to locate the fire

    A trench (strip) cut is a long, narrow opening, typically a few feet wide, cut wall to wall well ahead of the fire to create a break that stops horizontal spread. It supplements, and comes after, the primary vent hole over the fire; it is not the first opening and not a locating hole.

    Ref QB-Z88SX6Source: NFPA 1010 (2024) Ch. 6, Fire Fighter I — vertical ventilation JPR (trench cut)Report a problem with this question

  18. 18. Two firefighters are assigned to open a flat roof over a working fire. Which practice reflects safe roof operations?

    • A.Rely on one ladder since the roof will stay intact
    • B.Work with the wind at your back and keep two escape routes✓ Answer
    • C.Walk the center of bays between joists for footing
    • D.Work downwind of the cut so smoke clears the crew

    With the wind at their backs, smoke and heat from the opening blow away from the crew, and two separate escape routes protect them if one is cut off. Standing downwind puts them in the exhaust, the middle of a bay between supports is the weakest footing, and no roof over a fire can be assumed to stay intact.

    Ref QB-RRV9RFSource: NFPA 1010 (2024) Ch. 6, Fire Fighter I — vertical ventilation JPR (roof operations safety)Report a problem with this question

  19. 19. The attack crew is still stretching its hoseline to the front door when a ventilation team outside reports it is ready to take windows. When should the windows be opened?

    • A.Right away, since early venting improves conditions
    • B.Only after the fire has been completely extinguished
    • C.When the charged line is in place and ready to flow✓ Answer
    • D.As soon as the fire's exact location has been confirmed

    Ventilation without water lets a ventilation-limited fire grow rapidly, so openings are timed for when the attack line is charged and ready to put water on the fire. The old idea of venting early on its own is now known to worsen conditions, while knowing the fire's location alone does not control the added oxygen.

    Ref QB-89Q46FSource: UL FSRI — coordinated ventilation research; NFPA 1010 (2024) Ch. 7, Fire Fighter II — coordinating ventilation with interior attackReport a problem with this question

  20. 20. Before the attack line is ready, a crew forces the front door of a house with heavy smoke showing. Based on flow path research, how should that door be handled?

    • A.Remove it from its hinges to speed the hose advance
    • B.Prop it open and set a fan to blow out the smoke
    • C.Leave it wide open so the heat can escape the house
    • D.Keep it closed or nearly shut until water is ready✓ Answer

    An opened entry door is a ventilation opening that serves as an air intake for the fire. Keeping it closed or nearly closed until the line is ready limits the oxygen reaching the fire and slows its growth; leaving it open, removing it, or adding a fan feeds the fire before water can be applied.

    Ref QB-SV6GKUSource: UL FSRI — door control and flow path researchReport a problem with this question

Other topics in this exam

Original practice questions written to the job performance requirements of NFPA 1010 (2024), which replaced NFPA 1001 for Fire Fighter I and II, and NFPA 470 for hazardous materials Awareness and Operations. Not affiliated with or endorsed by NFPA, IFSAC, the Pro Board, or any state fire academy. Each state writes its own certification exam — check your state's fire academy or certification office for its format and which edition it tests. NFPA 1010 standard →