33 Roofing, Exterior & Site Practice Questions & Answers

Every Roofing, Exterior & Site practice question from the Home Inspector Practice Test (NHIE), with the correct answer and a short explanation.

Start practice test →
  1. 1. A porch roof with a very shallow pitch is covered with lapped asphalt shingles, and the inspector notes staining on the porch ceiling below. Which statement best expresses the principle that relates roof slope to the type of covering that belongs on it?

    • A.Lapped coverings perform best where water lingers, because the extra dwell time lets the self-sealing strips under each tab bond more completely and knit the laps into what is effectively a continuous sheet, so a shallow pitch improves weather resistance
    • B.Slope has no bearing on covering selection as long as an underlayment has been installed beneath the covering, because the underlayment is the true waterproofing layer and the shingles above it serve only as a wearing surface, and the covering itself is chosen for appearance rather than performance
    • C.A lapped covering only sheds water, because it depends on gravity and adequate slope to carry water over each lap before wind or standing water can drive it back underneath, so a shallow roof instead needs a continuous membrane with sealed seams✓ Answer
    • D.Any covering may be used at any slope provided the exposed fasteners are bedded in roofing cement at installation, since the cement seals every penetration and stops water from being driven back beneath the laps, which is why cemented fasteners are specified on low-slope work of every kind

    Lapped coverings such as shingles, shakes, slate and tile are water-shedding, not waterproof: each course simply overlaps the one below, and gravity must move water across that lap faster than wind pressure or ponding can push it back. When slope is too shallow for that to happen reliably, the assembly must change in kind to a continuous, seamed membrane rather than merely adding more laps.

    Ref QB-5GF262Source: National Home Inspector Examination content outline — roof components; residential building science, water-shedding versus waterproof roof assembliesReport a problem with this question

  2. 2. On an asphalt-shingle roof an inspector finds soft, roughly round spots of granule loss scattered randomly over all four slopes, some with a bruised, fractured mat that gives slightly under thumb pressure. On a different area, granule scuffing follows a narrow path from the ladder point to a rooftop appliance. What do these two patterns most likely indicate?

    • A.The random, soft, round bruises point to hail impact, because hail scatters strikes over every slope, while scuffing confined to the route between the ladder and the equipment points to mechanical foot-traffic damage✓ Answer
    • B.Both patterns are ordinary weathering and should be omitted from the report, because an asphalt shingle sheds granules continuously from the day it is installed and any bare spot is simply the normal end of that process
    • C.Both patterns indicate manufacturing defects in the shingles and neither is related to any outside force, since a mat that bruises under thumb pressure was blended with too little asphalt when the shingle was made, and a factory blending error of that kind shows up across all four slopes at once
    • D.The random bruises are foot traffic and the pathway scuffing is hail, since hail tends to fall along a single concentrated track rather than scattering impacts across every slope of the roof, so the concentrated track is the signature that identifies a hail event

    Distinguishing look-alike damage is a core inspection skill: hail arrives from the sky and therefore strikes randomly across all exposures, leaving soft, circular bruises where the mat is fractured beneath the granule loss, whereas foot traffic is human and therefore concentrated along access routes and around serviced equipment, producing linear scuffing and sometimes cracked tabs. The inspector reports the observed condition and its pattern rather than certifying a cause for an insurance claim.

    Ref QB-RR8HKUSource: National Home Inspector Examination content outline — roof coverings, typical defects and damage identificationReport a problem with this question

  3. 3. A home has a brittle clay tile roof. The inspector determines that walking the surface would crack tiles, and inspects instead from a ladder at the eaves and from the ground with binoculars. Which report language is most appropriate?

    • A.State that the roof was inspected from the eaves and from the ground with binoculars because walking the tile would damage it, describe the conditions observed, and note that this method limits what could be seen✓ Answer
    • B.Walk the roof anyway so the inspection is complete, and note any tiles broken during the inspection, since a report based on a partial view exposes the inspector to more criticism than a few replaced tiles would; a client is better served by a complete report than by a cautious one
    • C.State that the roof is in satisfactory condition and is not expected to leak during the client's ownership, because the tiles themselves are a mineral product that does not decay the way an organic covering does, and a covering that cannot rot is not a covering that can leak
    • D.Omit the roof entirely from the report, since a roof that cannot be walked cannot be inspected, and any comment offered without walking the surface would be speculation the client might rely on, which is why unwalkable roofs are routinely excluded from the scope of work

    A home inspection is visual and non-invasive and must not damage the property, so fragile coverings are properly viewed from the eaves, the ground or another vantage point. The report must state both what was observed and the method and resulting limitation, and it must never promise future leak-free performance or predict remaining service life.

    Ref QB-893CZTSource: Home inspection standards of practice — visual, non-invasive scope; reporting the method used and what was not inspected and whyReport a problem with this question

  4. 4. On an exposed-fastener metal panel roof, the inspector sees rust rings around many screw heads, several screws standing proud of the panel, and dark streaking on the panels below them. What is the most likely mechanism?

    • A.The screws leak because the sealing washers under the heads have hardened and lost compression and repeated thermal expansion and contraction of the panels has backed the screws out, leaving each fastener an open, leaking penetration✓ Answer
    • B.The streaking is algae growth and has no relationship to the fasteners, since dark stains running down a metal panel are colonies of airborne algae feeding on the mineral surface and are washed off rather than repaired, and pressure washing the panels restores the finish without any further work
    • C.The panels were installed over a membrane, so fastener condition is not a leak concern, because the membrane beneath the panels is the actual water barrier and the metal above it functions only as a decorative rain screen
    • D.The panels are oil-canning, which by itself causes the screws to loosen and rust, since the visible waviness in the flat of the panel is what works each fastener free of the substrate over time, so correcting the panel profile is what stops the fasteners from backing out

    An exposed-fastener metal roof is watertight only because a resilient washer is held in compression against the panel; ultraviolet exposure and heat harden that washer while daily thermal movement of long metal panels works the screws loose. Rust rings and backed-out screws therefore signal hundreds of active penetrations, and the rust staining below them is the corrosion product washing down the panel.

    Ref QB-QYBV35Source: National Home Inspector Examination content outline — roof coverings, metal roofing materials and typical defectsReport a problem with this question

  5. 5. On a low-slope built-up roof, water is still standing in a broad area three days after the last rain, the surfacing shows a network of fine cracks resembling dried mud, and several laps have lifted blisters. How should the inspector characterize these findings?

    • A.Blisters at the laps prove the roof deck is over-fastened and the framing is overloaded, because the raised areas mark the points where the structure below has deflected and pushed the membrane upward against its own laps, and the cracking in the surfacing follows those same deflected lines
    • B.Together they call for evaluation by a qualified roofing contractor, because water that fails to drain within a reasonable period indicates a drainage deficiency, alligatored surfacing an aged and embrittled coating, and blistered laps open paths for water✓ Answer
    • C.Alligatoring of the surfacing is purely cosmetic and never warrants comment, since the pattern of fine cracks affects only the top dressing and the reinforcing plies beneath it remain continuous and watertight, and the dressing can be recoated at any time as ordinary scheduled maintenance
    • D.Ponding is beneficial because the water ballasts the membrane against wind uplift, and the standing weight holds the sheet down over the field of the roof where mechanical attachment is weakest, so a roof that drains completely is actually more vulnerable in a windstorm

    Standing water on a low-slope roof adds sustained load, accelerates degradation of the surfacing and bitumen, and will find any open lap, so a roof that does not drain within a reasonable period after rain is reported as a drainage deficiency. Alligatoring is the surfacing shrinking and cracking as it ages and loses volatiles, and blistered or open laps are the seams that make a membrane continuous beginning to fail.

    Ref QB-7G6QG4Source: National Home Inspector Examination content outline — low-slope membrane roof coverings, ponding and typical defectsReport a problem with this question

  6. 6. Where a sloped roof meets a vertical sidewall, the inspector finds one continuous L-shaped metal strip running the full length of the intersection, with its vertical leg caulked to the siding. Why is this a defect?

    • A.The defect is the metal itself, since flashings at roof-to-wall intersections must be made of a flexible membrane that can move with the building; rigid sheet metal at such a junction will fatigue and split as the two surfaces expand and contract at different rates, leaving a split along the full length of the intersection within a few seasons
    • B.It is not a defect, because a single continuous piece has fewer joints than many small pieces and is therefore more watertight; every seam between individual flashings is another place for water to enter, so eliminating those seams improves the detail, and the fabricator's shop can form the strip to match the exact roof pitch
    • C.Continuous flashing is only a defect on the north side of a building, where drying is slower, and on the sunnier elevations the assembly dries quickly enough after each rain that the flashing method makes no practical difference, so the same detail is judged acceptable on east, west and south elevations
    • D.The intersection should be flashed with individual step flashings, one per shingle course, interwoven with the courses and lapped over by the wall's water-resistive barrier and cladding, so that any water reaching the wall is directed out onto the course below; a continuous strip has no such drainage path and relies on sealant✓ Answer

    Step flashing works because each individual piece is laid with a shingle course and lapped by the piece above, creating a stepped, shingle-fashion drainage path that hands water down and out onto the roof. A continuous strip breaks that layering: water running down the wall behind the cladding has nowhere to escape and the only thing keeping it out is a bead of sealant, which is a maintenance item and fails.

    Ref QB-PYYHW3Source: National Home Inspector Examination content outline — roof flashings, roof-to-wall intersectionsReport a problem with this question

  7. 7. A sloped roof intersects a two-story wall and terminates just above a gutter. There is no diverter at the lower end of the roof-to-wall flashing. Inside, the ceiling and wall below show staining, and the siding at that corner is soft. What is the most likely explanation?

    • A.Because there is no kickout (diverter) flashing at the lower termination, roof runoff concentrated in that valley of the intersection runs past the gutter and behind the cladding, saturating the sheathing and framing concealed within the wall✓ Answer
    • B.The staining is condensation from the interior and unrelated to the roof-to-wall detail, because warm indoor air reaching the cold sheathing inside that wall cavity deposits moisture there every heating season regardless of what happens outside
    • C.The gutter is undersized, and enlarging the gutter will resolve the interior staining, since the water now overshooting the trough is simply more than the existing profile can carry during a heavy rain; downspout capacity at the outlet is what governs how fast the trough clears
    • D.The shingles are the wrong color and are absorbing excess heat, driving moisture into the wall, because a dark covering on that slope raises the surface temperature enough to push vapor through the assembly, so a lighter covering on the same slope would keep the wall assembly dry

    The lower end of a roof-to-wall intersection collects the runoff from the whole roof plane above it, and a kickout flashing is the small angled piece that throws that concentrated stream out into the gutter. When it is missing, the water follows the wall face, gets behind the cladding, and rots sheathing and framing invisibly for years, which is why a missing kickout is a classic cause of major concealed damage.

    Ref QB-6GTCB3Source: National Home Inspector Examination content outline — roof flashings, kickout and roof-to-wall terminations; concealed moisture damage in wall assembliesReport a problem with this question

  8. 8. At a masonry chimney passing through a sloped roof, the base and step flashing appear sound, but the upper edge of the metal is simply bedded in a bead of sealant against the face of the brick. What is the correct description of this condition?

    • A.Counterflashing is unnecessary on any chimney that has a rain cap, because the cap sheds the water that would otherwise run down the flue and the masonry face stays dry enough for a sealant joint to last indefinitely, and the cap also keeps the flue itself dry through the whole heating season
    • B.This is the preferred method, because cutting a reglet into mortar weakens the chimney by removing bedding material from a joint that carries the courses above, and a surface bead avoids disturbing the masonry entirely, so a bead applied to the face is the method that preserves the chimney's strength
    • C.The condition is acceptable if the sealant is the same color as the mortar, since a color-matched joint indicates the installer used a masonry-grade product formulated to bond to brick and to move with it through the seasons, so a color-matched bead is itself evidence of a properly specified and durable repair
    • D.Counterflashing should be let into a mortar joint or reglet in the masonry and lapped down over the base flashing, so that water running down the chimney face is carried out over the flashing; sealant against the brick face is a maintenance item that will fail and is not a substitute✓ Answer

    Chimney flashing is a two-part system: base and step flashing turned up the masonry, and counterflashing let into the masonry above it and lapped down over the base. Letting the counterflashing into a joint puts the top edge behind the masonry so water on the wall cannot get behind the metal, which sealant alone can never accomplish once it shrinks, cracks and loses adhesion.

    Ref QB-SY2JE7Source: National Home Inspector Examination content outline — roof flashings and masonry chimney flashing detailsReport a problem with this question

  9. 9. A plumbing vent pipe penetrating an asphalt-shingle roof has a rubber boot collar that is split and cracked around the pipe, and a heavy trowelled layer of roofing cement has been applied over it. A stain is visible on the ceiling below. What is the best inspector response?

    • A.Report the cracked boot and note that the roofing cement is evidence of a previous repair attempt rather than a proper repair, describe the interior stain, and recommend replacement of the boot by a qualified roofing contractor✓ Answer
    • B.Apply additional roofing cement during the inspection to stop the active leak, since sealing the split while it is visible spares the client an emergency call and the added material bonds to the cement already in place and cures into the same monolithic patch over the pipe
    • C.Note that the cement has sealed the penetration and no further action is needed, because a trowelled layer over a cracked collar restores the water barrier at the pipe just as effectively as a new boot would, and the client saves the cost of a service call by leaving the repair in place
    • D.Report that the vent pipe is undersized and recommend a plumber enlarge it, as a pipe of insufficient diameter frosts closed in cold weather and forces condensate back down through the roof opening, so enlarging the pipe addresses the moisture at its source rather than the boot

    Rubber pipe-boot collars are among the most common single-item roof leak sources because ultraviolet exposure hardens and splits the collar long before the shingles wear out, and roofing cement over a failed detail is a temporary patch that cracks with thermal movement. The inspector observes and reports the condition and refers it to the appropriate trade rather than performing repairs, which is outside the scope of an inspection.

    Ref QB-9GVCU6Source: National Home Inspector Examination content outline — roof penetrations and flashings; standards of practice, inspectors observe and report rather than repairReport a problem with this question

  10. 10. An inspector finds gutters that hold standing water at the end farthest from the downspout, dark water staining and softened wood on the fascia directly behind the gutter, and downspouts that discharge onto the soil immediately at the foundation wall. Which statement best captures these findings?

    • A.Report all three, because back-pitched gutters hold water away from the downspout, water behind the gutter is rotting the fascia, and the downspouts soak the foundation soil; recommend correcting each condition✓ Answer
    • B.These are three unrelated cosmetic items that do not belong in an inspection report, since standing water in a trough, a weathered fascia board and a short downspout are maintenance details rather than performance defects
    • C.The fascia decay proves a roof covering failure directly above and the covering should be replaced, because water reaching the fascia has to have passed through the shingles and the sheathing at the eave first
    • D.Back-pitched gutters are desirable because they slow the water and reduce erosion at the downspout, holding each rainfall long enough that it leaves the outlet as a trickle rather than a scouring rush

    Roof drainage is a chain, and each link failed here: a gutter must fall toward its outlet or it holds water and debris, an edge flashing must carry water from the roof edge into the gutter or surface tension draws it back onto the fascia, and the discharge must be carried away from the building or the collected roof water is simply delivered to the backfill beside the foundation.

    Ref QB-UDFCUASource: National Home Inspector Examination content outline — roof drainage systems, gutters, downspouts and dischargeReport a problem with this question

  11. 11. After a snowfall, a house shows bare, melted roof over the main heated area but intact snow over the eave overhang, a thick ridge of ice at the eave with long icicles, and fresh staining on the top-floor ceiling near the exterior wall. What is the mechanism, and what is the durable correction?

    • A.The shingles are defective and are absorbing solar heat unevenly; replacing the covering will prevent future ice dams, because a covering that warms in patches is what melts the snow in patches and feeds the ridge of ice at the eave
    • B.The gutters caused the melting and removing the gutters entirely will eliminate the problem, since the trough holds a bank of snow against the eave that would otherwise slide clear before it had a chance to refreeze
    • C.Heat cable installed along the eave is the durable correction because it removes the cause of the dam, keeping a channel open through the ice so meltwater always has somewhere to go no matter how cold the overhang gets
    • D.Heat and air leaking from the living space melt snow over the warm deck, and the meltwater refreezes at the overhang because it is unheated, damming water back under the laps; the durable fix is air sealing, added insulation and balanced attic ventilation✓ Answer

    Ice damming is a building-science problem, not a roofing-material problem: the tell-tale is snow melted over the heated portion of the roof but intact over the unheated overhang, which proves interior heat is reaching the deck. Because a lapped covering only sheds water, ponded water held behind the dam runs backward under the laps; an eave ice barrier is protection against that, while heat cable only melts a channel through the symptom.

    Ref QB-CWMHEBSource: National Home Inspector Examination content outline — insulation, moisture management and ventilation of attics and roof assemblies; ice dam formationReport a problem with this question

  12. 12. The top of a masonry chimney is finished with a thin mortar wash that is cracked and crumbling, the upper courses of brick have faces flaking off, and the mortar joints there are eroded and soft. What best explains this deterioration and the correct detail?

    • A.The flaking is caused by flue gases condensing on the outside of the brick, and relining the flue will stop it, because combustion moisture that escapes a deteriorated liner migrates outward through the masonry and lifts the faces as it dries; the upper courses will stop flaking once the liner is sound again
    • B.Spalling is caused by the chimney being too tall, and shortening it is the correct repair, since the additional height increases the wind load and the resulting flexure at the top courses breaks the bond between brick and mortar; shortening the stack also reduces the exposure of the upper courses to rain
    • C.The flaking is normal patina on any brick over ten years old and requires no comment, as the outer skin of a fired clay unit is expected to weather away slowly and expose the denser body underneath, so a chimney of that age is expected to look weathered without being defective
    • D.A thin mortar wash cracks and lets water into the top of the chimney; absorbed water then freezes and expands within the brick and joints, flaking the faces and eroding the mortar. The proper detail is a cast, sloped crown that overhangs the chimney face with a drip edge, together with a rain cap✓ Answer

    A chimney crown is a roof for the masonry below it, and a thin mortar wash is too weak and too thin to survive thermal movement, so it cracks and admits water. Once masonry is chronically wet, freeze-thaw cycling breaks the fired face off the brick and washes out the joints, which is why a cast crown that overhangs with a drip edge, plus a rain cap, is the durable detail.

    Ref QB-TD42P9Source: National Home Inspector Examination content outline — chimney terminations, crowns, caps and masonry deteriorationReport a problem with this question

  13. 13. An inspector observes that an exterior masonry chimney has rotated away from the wall of the house, leaving a wedge-shaped gap that is wider at the top, with stair-step cracking in the mortar joints near the base. What is the appropriate action?

    • A.Report it as a cosmetic separation typical of differential settlement and note that no action is needed, because an exterior chimney bears on its own footing and is expected to move independently of the house it is built against, so the wedge-shaped gap simply records that independent movement
    • B.Determine the bearing capacity of the chimney footing and state in the report how much the footing must be underpinned, since quantifying the remedy in the report is what allows the client to price the repair before closing, and a figure stated in the report carries more weight than a recommendation
    • C.Report the observed movement as a significant and potentially unsafe condition, recommend that the chimney not be used until it is evaluated by a qualified structural professional, and note that the cause and extent cannot be determined by a visual inspection✓ Answer
    • D.Seal the gap with exterior sealant during the inspection so water cannot enter, as closing the opening at the top of the wedge keeps rain out of the joint and prevents the movement from accelerating over the winter, so sealing it during the visit is a service the client will not have to pay for

    A chimney rotating away from the house indicates footing failure or structural movement, and a leaning mass of masonry above a roof is a collapse and injury hazard as well as a flue-integrity concern. The inspector's role is to identify the condition, convey the safety implication, and refer it to the qualified professional, not to diagnose the cause, quantify the remedy or perform repairs.

    Ref QB-BW979ASource: National Home Inspector Examination content outline — analysis of findings and reporting; recommending evaluation by the appropriate qualified professionalReport a problem with this question

  14. 14. While siding was removed for a repair, the inspector can see that at one horizontal seam the upper sheet of water-resistive barrier was tucked behind the lower sheet. Why does this matter, and what principle governs wall assemblies?

    • A.It only matters in wind-driven rain climates, and sealing the seam with tape makes any lap direction acceptable, because a fully adhered tape restores continuity across the joint no matter which sheet was placed on top; taped seams are the method used on every modern wall of this construction
    • B.It matters only if the barrier is a paper-based product rather than a plastic housewrap, since a woven polymer sheet is impermeable enough that water reaching it will run down the face regardless of how the seam was formed, so the direction of the lap has no effect on where that water finally goes
    • C.It does not matter, because the cladding above is intended to be a sealed, watertight barrier and the barrier behind it is only a wind block, so no liquid water is expected to reach the seam in the first place, so the seam detail behind the cladding is not part of the drainage strategy
    • D.This is a reverse lap, which matters because a wall is a drained assembly: the water-resistive barrier and all flashings must be lapped shingle-fashion so any water past the cladding is directed outward and downward, and a reverse lap funnels it into the sheathing✓ Answer

    Modern wall design assumes some water will get past the cladding, so the cladding is treated as a screen and the water-resistive barrier behind it is the actual drainage plane. Because water moves by gravity, every lap and every flashing must be layered upper-over-lower; one reverse lap turns the drainage plane into a funnel that delivers water directly to the sheathing.

    Ref QB-SDRPG8Source: Residential building science — the drained wall principle, water-resistive barrier and shingle-fashion flashing integrationReport a problem with this question

  15. 15. At the base of a brick veneer wall the inspector finds that the small openings in the head joints have been filled with mortar and painted over. Inside, the lower wall shows efflorescence and damp staining. What is the significance?

    • A.Weep openings are decorative and closing them improves the wall's weather resistance, because every unfilled head joint is an opening through which wind-driven rain and insects can enter the cavity behind the veneer, so a mason who fills them is closing an unnecessary hole in the wall
    • B.Brick is impermeable, so any moisture inside must originate from interior humidity alone, since a fired clay unit absorbs essentially no water and the mortar joints between the units are the only permeable path, and interior ventilation is therefore the only correction worth recommending
    • C.Brick veneer is a drained assembly with an air space, a water-resistive barrier and through-wall flashing at its base; the weep openings are the only exit for water collected on that flashing, so blocking them traps water in the cavity and drives it inward✓ Answer
    • D.The efflorescence proves a plumbing leak inside the wall and the weeps are unrelated, as clean water from a supply line dissolves salts out of the masonry far faster than intermittent rainfall ever could, so the deposit points to a supply line rather than to anything about the veneer

    Brick absorbs and passes water, so a masonry veneer is designed to leak into a drainage cavity where through-wall flashing catches the water and weep openings let it back out. Sealing the weeps removes the exit while the entry remains, so the cavity holds water against the sheathing and dissolved salts appear as efflorescence when that moisture migrates and evaporates.

    Ref QB-AWWU39Source: National Home Inspector Examination content outline — wall cladding, masonry veneer drainage, through-wall flashing and weep openingsReport a problem with this question

  16. 16. A house is clad in an adhered synthetic stucco assembly. The inspector finds cracked and separated sealant at window perimeters and at a deck ledger penetration, with dark streaking below. What is the most appropriate report entry?

    • A.Report that synthetic stucco always performs adequately and that sealant cracking is cosmetic, because the base coat and mesh behind the finish carry the weather resistance on their own
    • B.Report that the cladding has failed and specify complete removal and replacement of the wall assembly, since sealant failure at every penetration means the only reliable remedy is to start the exterior over
    • C.Describe the sealant failure and staining, explain that this barrier-type cladding relies on sealed joints, and recommend invasive moisture evaluation by a qualified specialist, which is beyond a visual inspection✓ Answer
    • D.Probe the wall with a moisture meter through drilled holes during the inspection and report the readings as conclusive, treating each reading as a definitive measure of the condition of the framing behind

    A face-sealed assembly relies on the perfect-barrier strategy: with no drainage cavity behind it, every joint and penetration must stay sealed, so cracked sealant is a direct pathway rather than a cosmetic issue. Because damage occurs behind an intact-looking surface and confirming it requires probing, the inspector reports the visible condition and the limitation of a visual inspection and refers it out.

    Ref QB-RDDCB7Source: National Home Inspector Examination content outline — wall cladding types and typical defects; standards of practice, limits of a visual non-invasive inspectionReport a problem with this question

  17. 17. A double-glazed window shows a hazy film and faint mineral-looking streaks that are visible only in certain light and that do not change when both the inside and outside glass surfaces are wiped clean. What does this indicate?

    • A.The glass is dirty on the interior surface and only needs cleaning by the occupant, because a film that appears in raking light is ordinary household residue that has settled on the room side of the inner pane, where a soft cloth and a mild detergent will remove it completely
    • B.The perimeter seal of the insulated glass unit has failed, allowing moisture into the sealed cavity where it condenses and deposits residue between the panes; it cannot be corrected by cleaning and the unit or sash should be replaced✓ Answer
    • C.The haze is normal for all insulated glass and is not reportable, since every sealed unit develops a slight bloom on the cavity surfaces as the desiccant in the spacer gives up moisture over its service life, and every sealed unit of that age shows the same faint bloom to some degree
    • D.The window frame is out of square, which distorts the glass and creates the haze, as a racked sash bends the panes slightly and the resulting curvature scatters light across the surface in visible streaks, so squaring the sash in its opening will clear the appearance entirely

    An insulated glass unit is a sealed cavity, so the only way moisture appears between the panes is failure of the perimeter seal or its desiccant, and repeated condensation leaves mineral residue etched on the inner surfaces. The defining test is that the haze is between the panes and therefore unaffected by cleaning either exposed face, and visibility varies with temperature, humidity and sun angle.

    Ref QB-9WJHW7Source: National Home Inspector Examination content outline — exterior doors and windows, glazing condition and typical defectsReport a problem with this question

  18. 18. An attached deck ledger is fastened to the house rim area with common nails and coated deck screws, and there is no flashing above the ledger. How should the inspector treat this?

    • A.Note it as a minor workmanship item, since the deck is currently standing and shows no movement, and a connection that has already carried its load through several seasons has demonstrated it is adequate
    • B.Recommend the client add more of the same deck screws to increase the number of fasteners, because doubling the count of coated screws restores the capacity the connection needs at the house wall
    • C.Report that the ledger is acceptable if the deck is less than ten years old, as fasteners of that vintage have not had time to corrode enough to lose the grip they had when they were driven
    • D.Report it as a safety defect: the ledger carries the deck's load into the house and needs properly rated fasteners in a set pattern plus flashing over it; recommend correction by a qualified contractor before use✓ Answer

    Deck collapses overwhelmingly begin at the ledger, because that single connection transfers the entire deck load, including live load from occupants, into the house. Nails and generic deck screws are loaded in withdrawal and can pull out progressively without warning, and an unflashed ledger stays wet so the wood it bears on decays, which is why this combination is reported as an immediate safety concern rather than a workmanship note.

    Ref QB-YDVPHFSource: National Home Inspector Examination content outline — decks and balconies, ledger attachment, fasteners and flashing; life-safety findingsReport a problem with this question

  19. 19. Under a raised deck, the inspector finds the built-up beam nailed to the side face of each support post with angled nails, rather than bearing on top of the post or in a notch. Why is this reported as a defect?

    • A.The connection is acceptable as long as the posts are pressure-treated, since preservative treatment keeps the wood at the fastener holes from softening and that is what governs how much load the joint can carry over time, so pressure-treated posts make the side-nailed detail acceptable no matter how the beam bears
    • B.Side-nailed beams are stronger because the post can then be a smaller dimension, and moving the bearing to the face of the post lets the framing carry the same load on less material than a notched connection would need; the smaller post also leaves more open space beneath the deck for storage
    • C.The beam is hanging on nails rather than resting on the post, because toe-nailing loads the fasteners in withdrawal and cross-grain shear with no positive bearing; the beam should bear on top of the post or in a notch, with a positive metal connector, so the load transfers in direct compression✓ Answer
    • D.It is not a defect, because angled nails hold better than any other fastening method, as driving a fastener across the grain at an angle wedges it into the fibers and resists withdrawal better than a straight nail, so the angle of the fastener is what gives this connection its holding power

    Sound wood framing transfers vertical load through direct bearing, wood in compression, with metal connectors added to resist uplift and lateral displacement. Toe-nails were never intended to carry gravity load, so a side-nailed beam depends on a few nails in withdrawal that loosen with seasonal movement and vibration, and this is one of the most common findings behind deck failures.

    Ref QB-GW2V4GSource: National Home Inspector Examination content outline — decks and balconies, post-to-beam connections and load pathReport a problem with this question

  20. 20. A basement wall shows a white powdery deposit and damp staining along its base. Outside, the soil slopes back toward the house, mulch is piled above the bottom edge of the siding, and a downspout discharges at the wall. Which answer traces the complete path by which surface water reaches the basement?

    • A.Basement dampness is always caused by a high water table and site work cannot influence it, because water standing in the soil profile below the slab rises through the floor and walls under its own pressure no matter how the surface above is graded or where the roof water is discharged, and no amount of regrading or downspout work changes that outcome
    • B.Roof water is delivered by the downspout to the soil at the wall, negative grade holds that water against the foundation instead of carrying it away, the loose backfill stays saturated, and water then moves through the wall by pressure and capillary action, leaving dissolved salts as efflorescence as it evaporates inside✓ Answer
    • C.The mulch above the siding is the sole cause and removing it will dry the basement, since organic material held against the cladding wicks ground moisture upward and is the only path by which water reaches the wall, and pulling the mulch back below the siding line will dry the wall within weeks
    • D.The efflorescence is mold growth caused by interior humidity alone and has no exterior source, as the white deposit is a surface colony that forms wherever humid indoor air meets a cool below-grade wall, so an interior dehumidifier is the appropriate correction for that deposit

    Most basement water problems are surface-water problems, and the fix is at the top of the chain rather than inside: get roof water discharged well away from the building and slope the ground so it falls away from the foundation for a reasonable distance. Efflorescence is not the leak itself but its signature, the mineral salts left behind after water passed through the masonry and evaporated, and mulch above the siding line adds a wicking, decay-prone earth-to-cladding contact.

    Ref QB-T2QFBMSource: National Home Inspector Examination content outline — site conditions, grade and surface drainage; residential building science, surface water and foundation wettingReport a problem with this question

  21. 21. A segmental block retaining wall behind a house bulges outward at mid-height, the top course leans forward, no weep openings are visible at the base, and the soil behind the wall is saturated with a downspout discharging above it. What is the most likely mechanism and the correct inspector response?

    • A.Bulging in a retaining wall is normal seasonal movement and reverses each summer, because the soil behind the wall expands when it takes on winter moisture and draws back to its original volume once it dries out
    • B.The wall is rotating forward because trapped water builds hydrostatic pressure that proper drainage would relieve; report the movement, the missing drainage and the collapse hazard, and refer to a qualified engineer✓ Answer
    • C.The blocks were manufactured undersized, and repointing the joints will restore the wall, since filling the gaps that opened between courses re-establishes the bearing the units need to stand plumb again
    • D.The wall is fine because segmental block walls are designed to lean forward for appearance, and the forward set of the top course is an intentional architectural detail rather than evidence of any movement

    A retaining wall resists the lateral push of soil, and saturated soil pushes far harder than drained soil because water adds hydrostatic pressure to the earth pressure. Bulging, leaning, rotation and displaced courses are the visible evidence that the pressure exceeds what the wall was built to resist, and since the internal construction and any tie-backs cannot be seen, the inspector describes the condition and the hazard and refers it rather than diagnosing the design.

    Ref QB-AJHARKSource: National Home Inspector Examination content outline — site conditions, retaining walls, drainage and typical failure modesReport a problem with this question

  22. 22. During the inspection you observe that the concrete driveway has settled so it now slopes toward the attached garage, and the garage slab edge and the adjacent foundation wall show water staining. Which drainage expectation does this condition fail to meet?

    • A.Paved surfaces may be level near the house if all expansion joints are sealed
    • B.Paved surfaces must slope away only when the house has a basement below grade
    • C.Paved surfaces within 10 ft of the foundation must slope at least 2% away✓ Answer
    • D.Paved surfaces must fall at least 6 in within the first 3 ft of the foundation

    IRC R401.3 requires impervious surfaces within 10 ft of the building foundation to slope at least 2 percent away from the building, so a driveway that has settled toward the garage sends runoff to the slab edge and foundation, which the staining confirms. The 6-in figure in the same section applies to soil grade over the first 10 ft, not 3 ft, and neither sealed joints nor the absence of a basement removes the slope requirement. Report the reverse slope and recommend correction by a qualified concrete or drainage contractor.

    Ref QB-S2C56KSource: IRC 2021 R401.3 Drainage — impervious surfaces within 10 ft of the foundation sloped not less than 2 percent away from the buildingReport a problem with this question

  23. 23. At the rear of a house with wood lap siding, a raised planting bed has been filled so the soil now sits about 3 in below the bottom edge of the siding. Which statement correctly describes the required clearance and the finding?

    • A.Wood siding needs 6 in of clearance to soil; report a decay and insect-conducive condition✓ Answer
    • B.Wood siding needs 2 in of clearance to soil; the existing 3-in gap is therefore acceptable
    • C.Wood siding needs no set clearance to soil once it is primed and painted on every face
    • D.Wood siding needs 8 in of clearance to soil only where termite activity is already known

    IRC R317.1 item 5 requires decay protection (naturally durable or preservative-treated wood) for wood siding, sheathing and wall framing that is closer than 6 in to the earth, so ordinary wood siding needs at least 6 in of clearance. Soil 3 in below the siding keeps it wet and gives termites hidden access, so the inspector reports it as a conducive condition and recommends lowering the soil. The 2-in figure belongs to stucco weep screeds above paved areas, and the 8-in figure applies to framing resting on foundation walls; paint does not substitute for clearance.

    Ref QB-9J6YJJSource: IRC 2021 R317.1 Location required, item 5 — wood siding, sheathing and wall framing with less than 6 in clearance from the earth require decay protectionReport a problem with this question

  24. 24. During the exterior inspection you find dense shrubs pressed against the siding, ivy climbing onto the eaves, and a large tree limb hanging over the roof with leaves packed in the gutters. Under a typical home inspection standard of practice, how should these conditions be handled?

    • A.Leave all of it out, since landscaping is outside the scope of a home inspection
    • B.Report vegetation likely to cause moisture damage and recommend trimming it back✓ Answer
    • C.Report it only after an arborist confirms that the tree is diseased or dying
    • D.Report it only where roots have already cracked the foundation or a slab

    The InterNACHI Standards of Practice (3.2) direct the inspector to inspect vegetation, surface drainage, retaining walls and grading where they may adversely affect the structure due to moisture intrusion. Shrubs against siding hold moisture and hide decay and insects, ivy works into eaves, and an overhanging limb drops debris that clogs gutters and can damage roofing, so each is reportable with a recommendation to trim. The inspector does not need an arborist's diagnosis or visible structural damage before reporting a conducive condition.

    Ref QB-V2E5PPSource: InterNACHI Home Inspection Standards of Practice 3.2.I — inspect vegetation, surface drainage, retaining walls and grading where they may adversely affect the structure due to moisture intrusionReport a problem with this question

  25. 25. The only gate in a 5-ft fence around an in-ground pool swings inward toward the pool, and when released from the fully open position it simply stays open. The pickets are closely spaced. How should the inspector report the gate?

    • A.As acceptable, since the fence exceeds 48 in and gate details then do not matter
    • B.As a safety defect, since the gate should swing toward the pool and lock by key
    • C.As acceptable, since a gate only needs a latch that adults can reach from outside
    • D.As a safety defect, since the gate should open outward, self-close and self-latch✓ Answer

    ISPSC 305.3 requires pedestrian gates in a pool barrier to open outward away from the pool and to be self-closing with a self-latching device, so a child pushing on the gate cannot simply walk through and a gate left ajar closes itself. A tall fence is defeated by a gate that stays open, so the barrier fails even though it exceeds the 48-in minimum height of ISPSC 305.2.1. Pool equipment is outside a standard home inspection, but a deficient access barrier is reported as a safety hazard.

    Ref QB-CJ8Y3PSource: ISPSC 2021 Section 305.3 Gates — pedestrian gates open outward away from the pool, self-closing and self-latching; 305.2.1 barrier not less than 48 in highReport a problem with this question

  26. 26. A fixed glass sidelight stands beside an entry door in the same plane, with its nearest edge 18 in from the door and its bottom edge 12 in above the floor. No tempered or laminated mark can be found on the glass. What is the correct conclusion?

    • A.Not hazardous, because only glazing set in the door slab itself is regulated
    • B.Hazardous only if the single pane is larger than 9 sq ft in total area
    • C.Hazardous, because the glass is within 24 in of the door and under 60 in high✓ Answer
    • D.Not hazardous, because the adjacent-glass rule reaches only 12 in from the door

    IRC R308.4.2 makes glazing adjacent to a door a hazardous location when its bottom exposed edge is less than 60 in above the floor and it is within 24 in of either side of the door in the plane of the closed door. At 18 in from the door with a 12-in bottom edge, the sidelight meets both conditions, so it must be safety glazing; with no tempered or laminated mark, the inspector reports it as a safety concern and recommends evaluation. The 9-sq-ft test is a separate rule for large panes, not a condition of the adjacent-door rule.

    Ref QB-U23TGNSource: IRC 2021 R308.4.2 Glazing adjacent to doors — hazardous where bottom edge is less than 60 in above the floor and within 24 in of either side of the doorReport a problem with this question

  27. 27. The front door, which serves as the home's required egress door, has a deadbolt that needs a key to operate from both the inside and the outside. The seller explains that a key always hangs on a hook beside the door. What is the most appropriate finding?

    • A.Safety defect: an egress door must open from inside without a key or special knowledge✓ Answer
    • B.Acceptable: a key kept within reach of the door satisfies the egress requirement
    • C.Acceptable: double-keyed deadbolts are restricted only on bedroom and garage doors
    • D.Note only: the lock is a security feature that is outside the inspection's scope

    IRC R311.2 requires egress doors to be readily openable from inside the dwelling without the use of a key or special knowledge or effort. In a fire, smoke and panic make finding a key unreliable, and a key on a hook can be moved or lost, so a double-keyed deadbolt on the egress door is reported as a safety defect with a recommendation to install a thumb-turn on the interior side.

    Ref QB-BJVMWMSource: IRC 2021 R311.2 Egress door — readily openable from inside the dwelling without the use of a key or special knowledge or effortReport a problem with this question

  28. 28. A deck's walking surface is 34 in above the grade below. Its guard is 33 in tall, and the balusters are spaced so that a 5-in ball passes between them. Which statement is correct?

    • A.Both pass: guards need at least 30 in of height and must stop a 6-in sphere
    • B.Both fail: guards need at least 36 in of height and must stop a 4-in sphere✓ Answer
    • C.Height fails, spacing passes: guards need 42 in and must stop a 6-in sphere
    • D.Neither applies: guards are required only where the drop is more than 48 in

    IRC R312.1.1 requires a guard where a walking surface is more than 30 in above the floor or grade below, so this 34-in deck needs one. R312.1.2 sets the minimum guard height at 36 in and R312.1.3 prohibits openings that pass a 4-in sphere, so a 33-in guard with 5-in gaps fails both tests. The 6-in sphere applies only to the triangle formed by the riser, tread and bottom rail at stairs, and 42 in is a commercial (IBC) guard height, not the IRC residential minimum.

    Ref QB-X25TZRSource: IRC 2021 R312.1.1 (guards where more than 30 in above grade), R312.1.2 (36 in minimum height), R312.1.3 (4-in sphere opening limit; 6-in stair triangle exception)Report a problem with this question

  29. 29. While the automatic opener is closing the garage door, the inspector lays a 2x4 flat on the floor in the door's path. The door strikes the board, stops, and stays pressing down on it. What is the correct conclusion?

    • A.Acceptable: stopping on contact is sufficient as long as the photo-eyes work
    • B.Acceptable: reversal is required only on openers sold with a remote control
    • C.Adjustment item only: auto-reverse is a convenience, not a safety feature
    • D.Safety defect: the opener must reverse the door after striking an obstruction✓ Answer

    The federal standard for automatic residential garage door operators (16 CFR 1211.7(b)) requires a downward-moving door to initiate reversal within 2 seconds of contacting an obstruction, as inherent primary entrapment protection that must work whether or not photo-eyes are present. A door that stops and keeps pressing on the board could pin a child or pet, so the inspector reports it as a safety defect and recommends adjustment or repair by a garage door technician.

    Ref QB-EJXMERSource: 16 CFR 1211.7(b)(1)(i) Safety Standard for Automatic Residential Garage Door Operators — operator shall initiate reversal within 2 seconds of contact with an obstructionReport a problem with this question

  30. 30. In the attic, the inspector finds blown insulation packed tight against the roof sheathing at the eaves, burying the soffit vent openings. The underside of the sheathing near the ridge shows frost and dark staining. What is the most likely explanation?

    • A.Intake air is blocked; insulation must leave a 1-in air space at the eave vents✓ Answer
    • B.Exhaust is excessive; the ridge vent pulls in warm air and should be sealed off
    • C.Insulation is too thin; adding more over the soffits would stop the condensation
    • D.Ventilation is unrelated; frost on sheathing points only to a roof covering leak

    IRC R806.3 states that where eave or cornice vents are installed, insulation must not block the free flow of air and at least a 1-in space must be kept between the insulation and the roof sheathing at the vent. With the soffit intakes buried, little outside air enters at the bottom of the attic, so warm, moist air that leaks up from the house lingers and condenses or frosts on the cold sheathing near the ridge. The inspector reports the blocked intake and the moisture staining and recommends installing baffles and correcting the ventilation.

    Ref QB-QYPATGSource: IRC 2021 R806.3 Vent and insulation clearance — insulation shall not block the free flow of air; not less than a 1-in space between insulation and roof sheathing at the ventReport a problem with this question

  31. 31. A house in a region with a history of ice dams has fresh stains on the top-floor ceiling just inside the exterior walls. Photos from a recent reroof show the self-adhering membrane at the eaves was stopped exactly at the line of the exterior wall. Under the IRC, where should the ice barrier have ended?

    • A.From the eave edge to the exterior wall line, directly above the wall itself
    • B.From the eave edge up the slope a fixed 12 in, regardless of the overhang
    • C.From the eave edge to at least 24 in inside the exterior wall line✓ Answer
    • D.Over the entire roof deck, from eave to ridge, on every slope of the house

    IRC R905.1.2 requires the ice barrier, where ice damming is designated, to extend from the lowest edges of all roof surfaces to a point not less than 24 in inside the exterior wall line of the building. Ice dams form over the cold overhang and back water up the slope past the wall line onto the roof over heated space, so a membrane that stops at the wall leaves exactly the area above the stained ceiling unprotected. The inspector reports the leak evidence and recommends evaluation by a roofing contractor.

    Ref QB-8GVFDHSource: IRC 2021 R905.1.2 Ice barriers — extend from the lowest edges of all roof surfaces to a point not less than 24 in inside the exterior wall lineReport a problem with this question

  32. 32. A brick chimney about 36 in wide, measured across the slope, emerges partway down a sloped shingle roof. On its upslope side, leaves and debris collect against the brick and the shingles there are stained and worn. Which missing component would the inspector most likely note?

    • A.A kick-out flashing at the chimney base, required for chimneys over 30 in wide
    • B.A cricket or saddle on the upslope side, required for chimneys over 30 in wide✓ Answer
    • C.A second course of step flashing, required for chimneys over 24 in wide
    • D.A cricket or saddle on the downslope side, required for chimneys over 36 in wide

    IRC R903.2.2 requires a cricket or saddle on the ridge (upslope) side of any chimney or penetration more than 30 in wide measured perpendicular to the slope. Without it, water and debris dam against the wide upslope face, keeping the flashing and shingles wet and accelerating wear and leaks, which is exactly the pattern observed. Kick-out flashing belongs where a roof eave meets a sidewall, not at a chimney.

    Ref QB-RY2NYHSource: IRC 2021 R903.2.2 Crickets and saddles — required on the ridge side of any chimney or penetration more than 30 in wide measured perpendicular to the slopeReport a problem with this question

  33. 33. At the rake edge, the inspector sees that the current asphalt shingles lie over two older coverings: an earlier asphalt layer on top of original wood shingles. The seller says the newest layer was added as a recover rather than a tear-off. What is the most appropriate finding?

    • A.Acceptable: up to three layers are allowed on roofs with a 4:12 or steeper slope
    • B.Acceptable: the number of layers is limited only by what the framing can carry
    • C.Not permitted: asphalt shingles may never be installed over any existing roof
    • D.Not permitted: a recover is not allowed once two coverings are already present✓ Answer

    IRC R908.3.1.1 does not permit a roof recover where the existing roof has two or more applications of any type of roof covering, and also bars recovering over slate, clay, cement or asbestos-cement tile or a water-soaked, deteriorated base. A third layer adds weight, traps heat and moisture, and hides decking and fastening problems, so the inspector reports the excess layers and recommends evaluation by a roofing contractor. A single recover over one existing asphalt layer is permitted, so 'never' is incorrect.

    Ref QB-9G8TJJSource: IRC 2021 R908.3.1.1 Roof recover not allowed — item 3, where the existing roof has two or more applications of any type of roof coveringReport a problem with this question

Other topics in this exam

Practice questions based on the National Home Inspector Examination content outline, widely shared home inspection standards of practice, and residential building science. Not affiliated with or endorsed by any examination board, licensing authority, or inspector association. A home inspection is a visual, non-invasive examination and is not a code-compliance inspection — nothing here should be read as a code requirement. Home inspection is regulated differently from place to place; confirm your own jurisdiction's requirements and the standards of practice you are held to before testing or inspecting. About the National Home Inspector Examination →