EKG Technician (CET) Cheat Sheet: Key Facts
Every key takeaway and common trap from the EKG Technician (CET) study guide on one page, grouped by chapter. Tap a lesson link to read the full explanation.
44 facts · 5 chaptersFacts checked 2026-11-15
Chapter 1
Heart Anatomy & Conduction
Key takeaways
- On each side of the heart the AV valve (tricuspid or mitral) comes before the semilunar valve (pulmonic or aortic). → Heart chambers, valves and the path of blood
- The normal impulse runs SA node, internodal pathways, AV node, bundle of His, bundle branches, Purkinje fibers. → The conduction system and backup pacemakers
- Intrinsic rates are SA node 60 to 100, AV junction 40 to 60, and ventricles 20 to 40 beats per minute. → The conduction system and backup pacemakers
- A normal PR interval is 0.12 to 0.20 sec, and a QRS of 0.12 sec or more means the impulse did not fully use the His-Purkinje system. → What each wave and interval means
- The EKG records only electrical activity, so organized complexes do not prove the heart is pumping; always check the patient. → What each wave and interval means
Common trap
- Distractors often swap one valve, such as putting the aortic valve before the left ventricle or the tricuspid valve on the left side. Read every step of a sequence, not just the first and last. → Heart chambers, valves and the path of blood
- Do not confuse the four cell properties. Automaticity is firing on its own, excitability is responding to an outside impulse, conductivity is passing the impulse along, and contractility is shortening to pump. Only automaticity explains why a lower site can take over when the SA node fails. → The conduction system and backup pacemakers
- A common wrong answer says the T wave shows atrial repolarization. The T wave is ventricular only; atrial repolarization is buried in the QRS. → What each wave and interval means
Quick reference
| Pacemaker site | Intrinsic rate per minute | Usual QRS |
|---|---|---|
| SA node | 60 to 100 | Narrow |
| AV junction | 40 to 60 | Narrow |
| Ventricles (Purkinje) | 20 to 40 | Wide, 0.12 sec or more |
| Wall of the left ventricle | Leads that view it | Usual artery |
|---|---|---|
| Inferior | II, III, aVF | Right coronary artery |
| Septal and anterior | V1 to V4 | Left anterior descending |
| Lateral | I, aVL, V5, V6 | Left circumflex |
Chapter 2
12-Lead Placement
Key takeaways
- Ten electrodes give twelve leads: six chest leads from six chest electrodes and six limb leads from RA, LA and LL, with the right leg as the ground. → How ten electrodes make twelve leads
- Find the fourth intercostal space from the sternal angle, never from the nipple line. → Chest electrode landmarks, V1 to V6
- Place V4 before V3, because V3 is defined as the midpoint between V2 and V4. → Chest electrode landmarks, V1 to V6
- An inverted lead I with an upright aVR and normal chest leads means the arm electrodes are reversed; correct and repeat. → Spotting a misplaced or swapped electrode
- Torso placement is for monitoring and stress testing; a diagnostic resting 12-lead puts the limb electrodes on the limbs. → Special situations: torso placement, amputation, mastectomy, damp skin
Common trap
- Wrong answers often give the right leg electrode a job, such as feeding the augmented leads or forming the negative pole of lead III. It is only the ground. Lead III runs from the left arm (negative) to the left leg (positive). → How ten electrodes make twelve leads
- Placing chest electrodes by eye or by the nipple line often puts them an interspace or more off, most commonly with V1 and V2 too high. That shift distorts R-wave progression and can mimic an old anterior heart attack. Answers that skip palpation are wrong. → Chest electrode landmarks, V1 to V6
- V4R mirrors V4, not V1, and posterior leads stay level with V6 rather than dropping to the xiphoid or a vertebra. An unlabeled right-sided lead can be mistaken for a standard V lead. → Lead groups, right-sided leads and posterior leads
- Reversed arm electrodes and dextrocardia both flip lead I, but arm reversal cannot touch the chest leads. If R-wave progression across V1 to V6 is normal, it is a cable error to fix, not a finding to report. Filters, gain and paper speed never correct a placement error. → Spotting a misplaced or swapped electrode
Quick reference
| Bipolar lead | Negative | Positive |
|---|---|---|
| Lead I | Right arm | Left arm |
| Lead II | Right arm | Left leg |
| Lead III | Left arm | Left leg |
| Electrode | Position |
|---|---|
| V1 | 4th intercostal space, right sternal border |
| V2 | 4th intercostal space, left sternal border |
| V4 (place before V3) | 5th intercostal space, left midclavicular line |
| V3 | Midway between V2 and V4 |
| V5 | Left anterior axillary line, level with V4 |
| V6 | Left midaxillary line, level with V4 |
| What the tracing shows | Likely cause |
|---|---|
| Lead I inverted, aVR upright, chest leads normal | Right and left arm electrodes reversed |
| One limb lead nearly flat, others normal | Right leg electrode swapped with another limb electrode |
| rSr' complexes and inverted P or T waves in V1 and V2 | V1 and V2 placed one or two spaces too high |
| R-wave progression reverses between two neighboring chest leads | Chest electrodes out of order |
Chapter 3
Rhythm Identification
Key takeaways
- At 25 mm/sec a small box is 0.04 sec and a large box is 0.20 sec, so rate equals 1500 divided by small boxes or 300 divided by large boxes between R waves. → Reading the paper and calculating heart rate
- For an irregular rhythm, count the QRS complexes in 6 seconds and multiply by 10. → Reading the paper and calculating heart rate
- Normal sinus rhythm needs all five: rate 60 to 100, regular, an upright P before every QRS, PR 0.12 to 0.20 sec, and QRS under 0.12 sec. → Sinus rhythms: normal, slow, fast and variable
- In AV blocks, watch the PR interval: long but constant is first degree, lengthening until a drop is Mobitz I, constant with sudden drops is Mobitz II, and no relationship is third degree. → AV blocks: follow the PR interval
- Before naming a lethal rhythm, look at the patient; if the patient is unresponsive and pulseless, call for help and start CPR first. → Ventricular beats and rhythms, and checking the patient first
Common trap
- Applying 1500 to one R-R pair on an irregular strip gives a different answer for every pair you pick, and the bank lists those numbers as distractors. Also, 220 minus age estimates a maximum heart rate for stress testing; it is not a way to measure rate from a strip. → Reading the paper and calculating heart rate
- Do not call a breathing-linked irregular rhythm atrial fibrillation. If every QRS still has the same upright P and a fixed PR, it is sinus arrhythmia. → Sinus rhythms: normal, slow, fast and variable
- Missing upright P waves alone do not mean atrial fibrillation. A regular narrow rhythm at 40 to 60 is junctional, and a regular narrow rhythm near 150 with saw-tooth waves is flutter, not SVT. → Atrial and junctional rhythms
- Mobitz I and Mobitz II both drop beats, so the drop itself does not separate them. Check the PR just before the drop: lengthening means Mobitz I, unchanged means Mobitz II. → AV blocks: follow the PR interval
- Answers that say to complete the 12-lead, reposition electrodes, or report at the end of the study are wrong when the patient is pulseless. The patient is always treated before the tracing. → Ventricular beats and rhythms, and checking the patient first
Quick reference
| Method | How | Use when |
|---|---|---|
| 1500 method | 1500 ÷ small boxes between two R waves | Regular rhythm only |
| 300 (sequence) method | 300 ÷ large boxes, or 300, 150, 100, 75, 60, 50 | Regular rhythm only |
| 6-second method | QRS complexes in 6 seconds × 10 | Irregular rhythm (works for any) |
| Rhythm | Key features on the strip |
|---|---|
| Atrial fibrillation | No P waves, wavy baseline, irregularly irregular R-R; over 100 is a rapid ventricular response |
| Atrial flutter | Uniform saw-tooth atrial waves at about 250 to 350, no flat baseline between them |
| Supraventricular tachycardia | Regular, narrow, about 150 to 250, sudden onset, P waves often hidden in the T waves |
| Premature atrial complex | One early narrow beat with a differently shaped P, followed by a pause shorter than two full cycles |
| Junctional escape rhythm | Regular, narrow, 40 to 60, P absent or inverted (in lead II), sometimes just after the QRS |
| Block | PR interval | Dropped beats |
|---|---|---|
| First degree | Constant, longer than 0.20 sec | None |
| Second degree, Mobitz I (Wenckebach) | Grows longer beat by beat | One QRS drops, then the cycle repeats (group beating) |
| Second degree, Mobitz II | Constant on conducted beats | Sudden drops, more P waves than QRS |
| Third degree (complete) | No consistent PR; P and QRS march independently | No P conducts; slow escape rhythm |
Chapter 4
Artifact & Troubleshooting
Key takeaways
- Perfectly even, uniform fuzz is AC interference; jagged, irregular noise is somatic tremor; a slow drift with breathing is wandering baseline. → The three classic artifacts and how to tell them apart
- Fix the cause first: move power sources, warm and support the patient, re-prep the skin, use fresh electrodes, and relieve cable tension. → Fixing artifact at its source
- Artifact limited to a group of leads points to the one electrode those leads share; artifact equal in all twelve leads points to a global source. → Finding the faulty electrode from the leads affected
- Filters, gain and paper speed change how noise looks, not where it comes from, and any non-standard setting must be marked on the tracing. → Machine settings, honest records and artifact versus a real rhythm
- Never alter or trim a tracing; if artifact cannot be cleared, record the best tracing possible and document the limitation. → Machine settings, honest records and artifact versus a real rhythm
Common trap
- Answer choices often swap tremor and AC interference. Regularity decides it: even and uniform means AC, uneven and jagged means muscle. → The three classic artifacts and how to tell them apart
- Wrong answers often moisten dried electrodes with saline, press them down harder, tape them over a pulling cable, or turn on a filter. None of these removes the cause. → Fixing artifact at its source
- Do not blame the whole cable or the patient when only a few leads are noisy, and do not blame one electrode when all twelve leads carry the same noise that does not change when you touch any single wire. → Finding the faulty electrode from the leads affected
Quick reference
| Artifact | How it looks | Usual cause |
|---|---|---|
| AC (60-cycle) interference | Thick, fuzzy baseline; tiny waves of identical height at perfectly even spacing | Nearby powered equipment, cords, chargers, poor grounding |
| Somatic (muscle) tremor | Coarse, jagged spikes of varying height at irregular intervals | Shivering, anxiety, tremor disorders, tense unsupported limbs |
| Wandering baseline | Slow, smooth up-and-down drift, often in time with breathing; complexes stay sharp | Poor skin contact, lotion or oil, dried gel, pulling cables, breathing movement |
| Noisy leads | Shared electrode |
|---|---|
| I, II, aVR | Right arm |
| I, III, aVL | Left arm |
| II, III, aVF | Left leg |
| One chest lead only | That chest electrode or its wire |
| All twelve equally | None; a global source such as line current or grounding |
Chapter 5
Patient Safety & Professional Practice
Key takeaways
- Confirm identity with two patient-specific identifiers, such as full name and date of birth, checked against the order and the wristband; a room or bed number is never one of them. → Identifying the patient and communicating clearly
- A competent adult may refuse; stop, explain without pressure, notify the nurse and document the refusal. → Privacy, consent, orders and positioning
- After caring for a patient with C. difficile, wash with soap and running water, because alcohol rub does not kill the spores. → Infection control and responding to emergencies
- Stop a stress test for chest pain with pallor and sweating, call for help, and stay with the patient. → Infection control and responding to emergencies
- The technician does not interpret or release results, and record errors are fixed through the system's amendment process, never by deleting. → Scope of practice, patient privacy and the medical record
Common trap
- Asking 'Do you understand?' is not verification; a yes hides gaps. Saying the current is weak or the shock is brief is also wrong, because the machine sends no current at all. → Identifying the patient and communicating clearly
- A physician's order does not override a competent patient's refusal, and a relative's opinion does not replace the patient's consent. → Privacy, consent, orders and positioning
- In emergencies the wrong answers send the technician away to find help, finish the tracing first, or continue a stress test at a lower stage. Call for help from the bedside and stay with the patient. → Infection control and responding to emergencies
- Having access rights to a chart is not permission to discuss it, and a yes-or-no answer about a named patient's results is still a disclosure. → Scope of practice, patient privacy and the medical record
Quick reference
| Situation | First action |
|---|---|
| Chest pain with pallor and sweating during a stress test | Stop the test, alert the supervising provider, stay with the patient |
| Patient turns pale and dizzy on the exam table | Help him lie down, raise his legs, call for the nurse without leaving |
| Tracing shows a pattern you were trained to treat as critical | Check the patient, report to the nurse or ordering provider at once, stay |
| Very high blood pressure before a stress test | Recheck with correct cuff and arm at heart level, report before starting |