The SA node sits high in the right atrium near the superior vena cava. Its impulse spreads across the atria through the internodal pathways, reaches the AV node, passes into the bundle of His, splits into the right and left bundle branches, and ends in the Purkinje fibers.
A fibrous skeleton insulates the atria from the ventricles, so the AV node and bundle of His are the only normal route across. That single gateway lets the AV node delay each impulse.
Pacemaker cells have automaticity, the ability to fire with no outside stimulus. The site with the fastest intrinsic rate fires first and keeps the slower sites quiet. If it fails, the next fastest site escapes and takes over.
| Pacemaker site | Intrinsic rate per minute | Usual QRS |
|---|---|---|
| SA node | 60 to 100 | Narrow |
| AV junction | 40 to 60 | Narrow |
| Ventricles (Purkinje) | 20 to 40 | Wide, 0.12 sec or more |
Example: a slow rhythm at 30 per minute with wide complexes points to a ventricular site, because both the rate band and the width match the lowest level of the hierarchy.
Check yourself
1. The SA node stops firing and the AV junction takes over as the pacemaker. What intrinsic rate should the technician expect from that site?
2. Place the normal conduction pathway in order, beginning with the structure that normally starts the impulse.
Facts checked 2026-11-15 · Sources: NHA Certified EKG Technician (CET) certification and test plan, AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the ECG, Part I (Circulation, 2007)