Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/20 ▾
← Radiation Health & Safety

Chapter 1 · Lesson 1 of 4

How dental x-rays are produced and what the controls change

Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.

1 min read

Inside the tubehead, the cathode holds a tungsten filament. When it is heated, electrons boil off its surface, a process called thermionic emission. High voltage then drives that cloud of electrons toward the tungsten target in the anode.

When they strike the target, almost all of their energy turns into heat and only a very small fraction becomes x-ray photons. That is why the target is made of tungsten, with its high melting point, and is set in a copper stem surrounded by oil to carry the heat away.

ControlWhat it setsEffect on the image
Kilovoltage (kV)Penetrating quality of the beamContrast: higher kV gives many shades of gray (long scale), lower kV gives mostly black and white (short scale)
Milliamperage (mA) and exposure timeQuantity of radiationDensity: how light or dark the image is overall

Example: an image is too light overall but the dentist is happy with its range of grays. The fix is more quantity, a longer time or higher mA, not more kV, because kV would also change the contrast.

Digital sensors add a twist: the software adjusts brightness, so an image taken with too much exposure can still look fine on screen. The patient still received the extra dose, so settings are kept at the lowest level that answers the diagnostic question.

Check yourself

1. A dentist asks for images that show many shades of gray between the lightest and darkest areas. Which control should be changed, and in which direction?

2. Electrons from the filament strike the tungsten target inside the dental x-ray tube. What happens to the energy those electrons carry?

Facts checked 2026-11-15 · Sources: DANB: Radiation Health and Safety (RHS) exam, FDA and ADA: The Selection of Patients for Dental Radiographic Examinations

Dental Assistant (DANB) cheat sheet: every key fact on one page →