Chapters0/68 ▾
- 1.Medical Terminology & Anatomy0/5
- 2.ICD-10-CM Guidelines & Conventions0/5
- 3.Evaluation & Management (E/M)0/5
- 4.Anesthesia0/5
- 5.Surgery: Package & Cross-Section Rules0/5
- 6.Surgery: Integumentary & Musculoskeletal0/5
- 7.Surgery: Respiratory, Cardiovascular & Digestive0/5
- 8.Surgery: Urinary, Reproductive, Endocrine & Nervous0/5
- 9.Radiology0/5
- 10.Pathology & Laboratory0/5
- 11.Medicine0/5
- 12.Modifiers & HCPCS Level II0/5
- 13.Compliance & Regulatory0/4
- 14.Case Studies0/4
Chapter 7 · Lesson 2 of 5
Heart: pacemaker generators and coronary bypass grafts
1 min read
Pacemaker and defibrillator questions usually turn on two facts. First, generator replacement codes are split by how many leads are connected to the new generator: single, dual, or multiple. Second, every replacement code already includes taking out the old generator, so the removal-only code is never added to a replacement.
Lead repair has its own codes. NCCI says a lead repair includes opening the pocket and putting the original device back. If the battery is also failing and a new generator goes in during the same session, the replacement code may be reported in addition to the lead repair.
| Bypass grafts used | Code families to report |
|---|---|
| Vein grafts only | One code from the venous-only family |
| Artery grafts only | One code from the arterial family |
| Artery and vein grafts | One arterial code plus one arterial-venous add-on code |
Each code is chosen by counting the grafts of its type, and harvesting the saphenous vein from the leg is included. Example: two internal mammary artery grafts plus one leg vein graft are reported with the arterial code for two grafts and the arterial-venous add-on for one vein graft, with no harvest code.
Check yourself
1. A patient has a dual-chamber pacemaker with atrial and ventricular leads. The surgeon opens the pocket, repairs the insulation of the atrial lead (33218), and because the battery is near depletion replaces the generator with a new one connected to both existing leads. Generator replacement is 33227 single, 33228 dual and 33229 multiple lead system; generator removal alone is 33233. How is the session reported?
2. A patient with two-vessel coronary disease undergoes on-pump coronary bypass through a median sternotomy. The surgeon takes down the left internal mammary artery as a pedicle and anastomoses it to the LAD, then takes down the right internal mammary artery and anastomoses it to the posterior descending artery. Both mammary grafts stay attached at their origins. A third possible target, a small diagonal branch, is inspected and judged too small to graft. No saphenous vein or radial artery is harvested. Available codes: 33511 CABG, venous grafts only, 2 grafts; 33533 CABG, arterial grafts, 1 graft; 33534 CABG, arterial grafts, 2 grafts; 33535 CABG, arterial grafts, 3 grafts. Which code should be reported?
Facts checked 2026-11-15 · Sources: AAPC: Taking the CPC Exam, CMS: Medicare NCCI Policy Manual (Chapters V and VI)
CPC Medical Coding cheat sheet: every key fact on one page →