X-rays, mammography and bone density
1 min read
Plain x-ray codes are chosen by body part and views. A code is reported only when every element of its descriptor was done, so a view count alone cannot meet a code that also requires specific views, such as bending views. A code written as a minimum number of views is reported once, and extra views are already covered.
- Repeat films for poor quality in the same encounter are one unit, even if the patient left and came back. Only a change in condition supports a new study.
- If the descriptor already names both sides, report one unit with no 50, RT or LT.
- Manual stress views: the stress code is one unit and already includes the opposite joint, and the anatomic x-ray code chosen by the number of views is reported with it.
- Mammography is screening or diagnostic by the reason for the exam. Current codes include computer-aided detection when used, and tomosynthesis follows the mammogram's purpose; the screening add-on pairs only with a screening study.
- Medicare, same day: when a screening mammogram leads to a diagnostic one, the diagnostic line takes modifier GG and the screening line takes 59 or XU.
- Bone density: NCCI allows one axial and one peripheral study on the same date, but not two of the same type.
Example: a wrist series is taken with five views under a code written as a minimum of three views. Report that code once.
Check yourself
1. A woman with no symptoms attends her routine annual mammogram of both breasts, and the radiologist uses computer-aided detection (CAD) software. Under current CPT logic, how is this reported?
2. A physician manually stresses a knee while radiographs are taken, and the opposite knee is stressed for comparison. CPT has a code for manual application of stress, including the contralateral joint if indicated, and it directs the interpretation of stressed images to the anatomic site and number of views. What is reported?
Facts checked 2026-11-15 · Sources: AAPC: Taking the CPC Exam, CMS: Medicare NCCI Policy Manual (Chapter IX, Radiology), CMS: Medicare Claims Processing Manual, Chapter 13 (Radiology Services)
CPC Medical Coding cheat sheet: every key fact on one page →