19 A7 — Heating & Air Conditioning Practice Questions & Answers
Every A7 — Heating & Air Conditioning practice question from the ASE Automotive Technician Practice Test, with the correct answer and a short explanation.
Start practice test →1. A refrigerant identifier test before recovery shows an unknown mixture that is not pure R-134a or pure R-1234yf. What should the technician do with it?
- A.Recover it into a separate cylinder labeled contaminated✓ Answer
- B.Recover it with the R-134a machine and recycle it as usual
- C.Release it slowly outdoors, away from any ignition source
- D.Top it off with R-134a until the identifier shows a pass
Refrigerant that is not a single pure type cannot be cleaned to purity standards by a recycling machine, and running it through a single-refrigerant machine would contaminate the machine and its stored supply. It is recovered with dedicated equipment into a cylinder reserved for contaminated refrigerant and sent for reclaim or destruction. Intentional venting is prohibited, and adding more refrigerant only makes the mixture worse.
Ref QB-WUDSC5Source: ASE Automobile Study Guide (2024), A7 sample question 1, p. 50; 40 CFR 82.36(a)(9) (SAE J2851 recover-only equipment for contaminated R-134a/R-1234yf); 40 CFR Part 82 Subpart B: intentional venting is an improper use of equipmentReport a problem with this question
2. A compressor failure has sent metal debris through the system. Why is a long, deep evacuation alone not enough to clean it out?
- A.A vacuum pulls out particles but leaves the moisture
- B.A vacuum pulls out air and moisture but not particles✓ Answer
- C.A vacuum pulls out particles only from the high side
- D.A vacuum pulls out particles only once the system is hot
Evacuation lowers system pressure so air is pulled out and moisture boils off and leaves as vapor, but solid particles do not evaporate and stay where they are. Debris has to be removed by flushing the parts that can be flushed and replacing the parts that cannot, such as the accumulator or receiver-drier, the orifice tube or expansion valve, and multi-pass condensers.
Ref QB-ECKXX5Source: ASE Automobile Study Guide (2024), A7 sample question 3, p. 50; Four Seasons Virtual PAC-Kits flyer (flush system, replace accumulator/drier and orifice tube/TXV; multi-pass condensers cannot be flushed)Report a problem with this question
3. Refrigerant is being added while the engine is running and the compressor is engaged. Where should it be added?
- A.Through the high-side port only
- B.Through both ports at the same time
- C.Through the low-side port only✓ Answer
- D.Through either port, as convenient
With the compressor running, the high side is at discharge pressure, which is higher than the pressure in the charging source, so refrigerant cannot flow in there and can instead be pushed back toward the hose and container. The low side is at suction pressure, below the source pressure, so the compressor draws refrigerant in. A running system is therefore charged through the low side only.
Ref QB-XUR4J6Source: ASE Automobile Study Guide (2024), A7 sample question 5, p. 51Report a problem with this question
4. On a hot day the A/C blows only slightly cool air. At fast idle on max A/C, both the low-side and high-side readings are well below the manufacturer's pressure chart for that ambient temperature. What is the most likely cause?
- A.An overcharged system
- B.Leaking reed valves
- C.Blocked condenser air
- D.An undercharged system✓ Answer
With too little refrigerant the evaporator is starved, so suction pressure drops, and there is too little vapor for the compressor to build normal head pressure, so both gauges read low. An overcharge or poor condenser airflow raises the high side, and leaking reed valves give a high low side with a low high side.
Ref QB-BCHXE2Source: ASE Automobile Study Guide (2024), A7 sample questions 6 and 8, p. 51; StarTuned 'A/C Refrigeration System Diagnosis' (very low suction = lack of refrigerant; high suction with low discharge = failing compressor)Report a problem with this question
5. How can a technician check a cylinder of recovered R-134a for non-condensable gases such as air?
- A.Let it settle and compare its pressure to a PT chart✓ Answer
- B.Weigh it and compare with the stamped tare weight
- C.Measure the liquid temperature with an IR thermometer
- D.Check the color of oil drained from the machine
Pure refrigerant in a closed cylinder sits at the saturation pressure for its temperature, which is what the pressure-temperature (PT) chart lists. After the cylinder has stood long enough to reach a stable temperature, a pressure noticeably above the chart value means air or other non-condensables are present, because they add pressure without condensing. Weight, temperature alone or oil color cannot reveal this.
Ref QB-UUP423Source: Appion, 'Non-condensables in Refrigerant Recovery' (check cylinder pressure and temperature against the refrigerant's PT chart); ASE A7 Task List A.18, ASE Automobile Study Guide (2024) p. 47Report a problem with this question
6. A hybrid vehicle has a high-voltage electric A/C compressor. Which lubricant rule matters most when servicing it?
- A.Use standard PAG oil, as in belt-driven R-134a systems
- B.Use only the specified non-conductive oil, not standard PAG✓ Answer
- C.Use mineral oil, because it is the most moisture resistant
- D.Use any A/C oil, because the motor windings are sealed
An electric A/C compressor is powered from the high-voltage battery, and its oil must also serve as an electrical insulator. Standard PAG oil does not have the needed insulating properties, so manufacturers specify a non-conductive POE oil (or a special PAG). Cross-contamination with standard PAG can create a shock hazard and damage the compressor, which is why dedicated service equipment or oil injectors are used.
Ref QB-CCV9M3Source: Behr Hella Service, 'Air-conditioning high-voltage compressors' (standard PAG lacks insulation properties; POE or special PAG used); Subaru of America notice, Crosstrek Hybrid A/C Compressor Oil, Aug. 15, 2019 (non-conductive POE; PAG must never be used)Report a problem with this question
7. To test for electrolysis, the DVM negative lead is placed on the battery negative post and the positive lead in the coolant, not touching metal. Above roughly what reading do common test procedures confirm stray current in the coolant?
- A.About 0.03 V DC
- B.About 12 V DC
- C.About 0.3 V DC✓ Answer
- D.About 3.0 V DC
When a component has a poor ground, current looks for another path and can flow through the coolant, turning it into an electrolyte that eats soft metals such as the heater core and radiator. Test procedures treat a reading above about 0.3 V as confirmed electrical leakage into the coolant; some procedures screen even lower, at about 0.1 V, and near 0 V is the target once the faulty circuit or ground is fixed. Readings of 3 V or 12 V would be gross faults far above where corrosion damage starts, and 0.03 V is within normal.
Ref QB-VU2F74Source: Four Seasons Tech Tip 350, 'Electrolysis: A Major Cause of Heater Core Failure' (reading above 0.300 V); Mighty Tech Tip 218, 'Cooling System' (over 0.3 V confirms leakage; below 0.1 V identifies the problem circuit); ALLDATA Tech-Assist, 'Checking Electrolysis' (more than 0.10 V = a component using coolant as ground); ASE A7 Task List A.22 (electrolysis test)Report a problem with this question
8. A customer complains of weak heat. While the engine warms up from a cold start, the upper and lower radiator hoses get warm at the same rate. What does this indicate?
- A.The thermostat is stuck closed
- B.The heater core is plugged
- C.The blend door is stuck cold
- D.The thermostat is stuck open✓ Answer
A working thermostat stays closed during warm-up, so coolant bypasses the radiator: the upper hose warms slowly and the lower hose stays cool until the thermostat opens. If both hoses warm together from the start, coolant is flowing through the radiator the whole time, so the thermostat is stuck open or missing and the coolant never gets hot enough for good heat. A stuck-closed thermostat keeps the lower hose cold and causes overheating, and heater core or blend door faults do not change radiator hose behavior.
Ref QB-HCNXF9Source: Nissan TechNews (Summer 2015), 'Attack HVAC!', No Heat section (if both radiator hoses rise equally, the thermostat is stuck open or missing)Report a problem with this question
9. Under EPA rules for motor vehicle A/C, what applies to the service fittings used with R-1234yf?
- A.Each refrigerant has unique fittings; no adapters allowed✓ Answer
- B.R-1234yf shares R-134a fittings, so the same hoses can be used
- C.Adapters are allowed as long as the machine is J2788 certified
- D.Unique fittings apply only to small cans, not to the vehicle
Under the SNAP program, EPA requires a unique set of fittings for each approved MVAC refrigerant, on the vehicle, on recovery and recycling equipment, and on containers, so different refrigerants cannot be mixed by accident. EPA states that an adapter may not be used to convert a fitting. J2788 equipment is certified for R-134a; R-1234yf machines are certified to J2843 (or J3030 for dual-refrigerant units).
Ref QB-2VT43ASource: EPA, 'Unique Fittings and Label Colors' (MVAC): unique fittings for each refrigerant; an adapter may not be used to convert a fitting; 40 CFR 82.36(a)(4), (a)(8), (a)(10)Report a problem with this question
10. High-side pressure is above specification. Any of these could be the cause EXCEPT:
- A.air trapped in the system
- B.an inoperative condenser fan
- C.an overcharge of refrigerant
- D.leaking compressor reed valves✓ Answer
Air in the system, too much refrigerant and poor condenser airflow (such as a fan that does not run) all keep refrigerant from condensing normally, so head pressure climbs. Leaking reed valves let compressed gas slip back to the suction side, so the compressor cannot build pressure: the low side reads high and the high side reads low.
Ref QB-RU6T8RSource: ASE Automobile Study Guide (2024), A7 sample question 8, p. 51; StarTuned 'A/C Refrigeration System Diagnosis' (causes of excessive head pressure; high suction with low discharge = failing compressor)Report a problem with this question
11. After a compressor clutch is reassembled, how is the air gap between the armature and the rotor checked and corrected on a typical shim-adjusted clutch?
- A.Measure coil resistance; replace the pulley bearing
- B.Measure with feeler gauges; add or remove shims✓ Answer
- C.Measure with a dial bore gauge; replace the coil
- D.Measure with a straightedge; tighten the shaft nut
The air gap is a mechanical clearance, so it is measured directly with feeler gauges between the armature plate and the rotor face. On shimmed clutches, the shims under the armature set its position on the compressor shaft, so adding or removing shims moves the armature and brings the gap into the specified range. Coil resistance, bore gauges and nut torque do not set this clearance.
Ref QB-8CZMNQSource: Sanden TRS090/105 Compressor Repair Procedures, Clutch Reassembly step 6 'Air Gap Adjustment' (measure with feeler gauges; add or remove shims)Report a problem with this question
12. In an orifice tube system, where is the accumulator located, and what is one of its jobs?
- A.After the condenser, to keep vapor out of the orifice tube
- B.Before the condenser, to cool the hot discharge gas
- C.After the evaporator, to keep liquid out of the compressor✓ Answer
- D.Before the evaporator, to meter refrigerant into it
An orifice tube is a fixed restriction that cannot regulate flow, so at low heat loads liquid refrigerant can leave the evaporator. The accumulator is installed on the low side downstream of the evaporator; it slows the flow so liquid drops settle out, stores refrigerant, holds desiccant and returns oil to the compressor through a small bleed hole. A receiver-drier, by contrast, sits on the high side after the condenser in expansion valve systems.
Ref QB-QUTF3QSource: TRD Air Conditioning Training Manual (2009), Ch. 4 'Liquid separator (accumulator)' installed downstream of the evaporator; Valeo TSB-VSA-VCC-062021-01 (accumulator/orifice tube system; orifice tube cannot regulate flow)Report a problem with this question
13. A blower controlled by a switch and a resistor block works on the highest setting but not on any lower setting. What is the most likely cause?
- A.An open blower motor resistor✓ Answer
- B.Worn blower motor brushes
- C.An open blower motor ground
- D.A failed blower motor relay
In a resistor-type blower circuit, the lower speeds send current through the resistor coils to reduce the voltage at the motor, while the high position bypasses the resistor and feeds the motor directly. Because high speed still works, the motor, its ground and its feed must be good; the part used only by the lower speeds, the resistor, is the one that is open.
Ref QB-7CNAGPSource: ASE Automobile Study Guide (2024), A7 sample question 4 (blower works only in the #4 position = failed blower motor resistor), p. 50Report a problem with this question
14. An automatic climate control system set to 72°F keeps blowing hot air from the dash vents on high blower. Which sensor fault could cause this?
- A.A shorted duct temperature sensor
- B.A sun load sensor left in shade
- C.An open duct temperature sensor✓ Answer
- D.A shorted ambient air sensor
ATC temperature sensors are typically NTC thermistors, so an open circuit (very high resistance) is read by the module as an extremely cold temperature. Believing the discharge air is far too cold, the module drives the blend door toward full heat. A shorted sensor reads as very hot and pushes the system toward cooling, and a shaded sun load sensor reduces the heat load the module compensates for.
Ref QB-PUF5WNSource: ASE Automobile Study Guide (2024), A7 sample question 2 (ATC blows hot air at 72°F on HIGH = open duct temperature sensor), p. 50Report a problem with this question
15. With A/C requested, a DMM connected between battery negative and the A/C clutch coil's power terminal reads 14.2 V, but the clutch does not engage. What is the most likely cause?
- A.An open clutch coil diode
- B.A blown A/C clutch fuse
- C.An open low-pressure switch
- D.An open clutch coil winding✓ Answer
Full charging-system voltage at the coil's power terminal proves the fuse, pressure switches and relay are all delivering power, so the fault is in the coil itself or its ground. An open coil winding cannot build the magnetic field that pulls in the armature. The diode sits in parallel with the coil only to absorb the voltage spike when the coil switches off, so an open diode would not prevent engagement.
Ref QB-6CAYANSource: ASE Automobile Study Guide (2024), A7 sample question 7 (14.2 V at clutch coil positive, no engagement = failed clutch coil, not diode), p. 51Report a problem with this question
16. On many late-model vehicles, the climate control unit requests compressor operation, but the clutch is not engaged while the engine is overheating. Which module typically makes that decision?
- A.The airbag control module
- B.The engine control module✓ Answer
- C.The blower control module
- D.The instrument cluster module
The climate control unit only requests the compressor. The engine control module decides whether to grant that request based on engine conditions and passes it on to the module that powers the clutch. If the engine is overheating or heavily loaded, the ECM withholds the request to protect the engine, so no engagement in that situation is normal load-sensitive control rather than an HVAC fault.
Ref QB-NU4TQMSource: Nissan TechNews (Summer 2015), 'Attack HVAC!', A/C Compressor Clutch (climate unit sends request to the ECM, which relays it provided the engine is not overloaded or overheating); ASE A7 Task List C.5 (load-sensitive compressor controls)Report a problem with this question
17. On a system with a refrigerant pressure sensor in the clutch control, when will the system normally stop the compressor clutch?
- A.At both the high and low limits✓ Answer
- B.At the high-side pressure limit only
- C.At the low-side pressure limit only
- D.Whenever engine speed rises quickly
The sensor protects the compressor in both directions. Excessive pressure strains and can damage the compressor, and very low pressure usually means low refrigerant, which also means poor oil circulation and lubrication. The control system therefore breaks the clutch circuit when pressure is either too high or too low.
Ref QB-5CXM5MSource: Nissan TechNews (Summer 2015), 'Attack HVAC!', Refrigerant Pressure Sensor (breaks the compressor clutch circuit when pressure is too high or too low); ASE A7 Task List B.1–B.2Report a problem with this question
18. With the car parked inside the shop, the automatic climate control module stores a sun load sensor code. What is a reasonable first step?
- A.Replace the sun load sensor right away
- B.Recalibrate the blend door actuators first
- C.Replace the in-car temperature sensor first
- D.Shine a bright light on it, then recheck✓ Answer
A sun load sensor responds to light, and indoors with no sunlight its output can drop low enough for the module to flag it even though the sensor is fine. Shining a strong light on it and rechecking shows whether it responds before any part is replaced. The in-car sensor and the door actuators have nothing to do with this code.
Ref QB-MURFJKSource: Nissan TechNews (Summer 2015), 'Attack HVAC!', Sunload Sensor (code typically sets when there is no sun, as in the shop; shine a bright flashlight on the sensor to clear it)Report a problem with this question
19. On a blower controlled by a duty-cycle (PWM) module, how does the module make the blower run faster?
- A.It adds more series resistance
- B.It increases the signal's on-time✓ Answer
- C.It reverses the motor polarity
- D.It decreases the signal's on-time
A PWM controller switches the motor's power on and off rapidly, and the share of each cycle that is on (the duty cycle) sets the average voltage the motor receives. More on-time means a higher average voltage and a faster blower. Series resistors belong to older resistor-block systems, and reversing polarity would reverse a DC motor, not speed it up.
Ref QB-4CKAYJSource: Nissan TechNews (Summer 2015), 'Attack HVAC!', Blower Motor (controlled by duty cycle; the more on-time, the faster the motor spins)Report a problem with this question
Other topics in this exam
Practice questions written to the ASE Automobile & Light Truck (A-series) task lists and standard automotive service principles. ASE is a mark of the National Institute for Automotive Service Excellence; this site is not affiliated with or endorsed by ASE. Always follow the vehicle manufacturer's service information for specifications and procedures on a real repair. About the ASE tests →