Quibank app: now on the App Store — free, works offline. Get the app ↗

41 Surgery: Respiratory, Cardiovascular & Digestive Practice Questions & Answers

Every Surgery: Respiratory, Cardiovascular & Digestive practice question from the CPC Medical Coding Practice Test, with the correct answer and a short explanation.

Start practice test →

Practice tests

  1. 1. A surgeon inspects the nasal cavity with a rigid endoscope (31231, diagnostic nasal endoscopy), then opens the right maxillary ostium and removes polypoid tissue from the sinus (31267, surgical sinus endoscopy with maxillary antrostomy and tissue removal; 31256 is the antrostomy without tissue removal). How is the right side reported?

    • A.Report the code with tissue removal alone, with the inspection and the antrostomy both included✓ Answer
    • B.Report the antrostomy code plus the diagnostic endoscopy, with the tissue removal treated as included
    • C.Report the code with tissue removal plus the diagnostic endoscopy, with modifier 59 on the endoscopy
    • D.Report the code with tissue removal plus the antrostomy code, with modifier 51 on the antrostomy

    A surgical sinus endoscopy includes the sinusotomy when appropriate and the diagnostic endoscopy, so the most comprehensive code that names the work on that sinus stands alone. Adding a modifier does not unbundle an inspection or antrostomy that is a component of the same scope procedure.

    Ref QB-V2PY66Source: AMA CPT guidelines for Nasal/Sinus Endoscopy (surgical sinus endoscopy includes sinusotomy when appropriate and diagnostic endoscopy); CMS NCCI Policy Manual for Medicare, Chapter V (Surgery: Respiratory, Cardiovascular, Hemic and Lymphatic Systems)Report a problem with this question

  2. 2. During a septoplasty the surgeon cauterizes the right inferior turbinate solely to stop intraoperative mucosal bleeding. The turbinate codes are 30801 (superficial) and 30802 (intramural). Under NCCI policy, how is the session reported?

    • A.Report the septoplasty alone, because control of operative bleeding is integral to that nasal procedure✓ Answer
    • B.Report the septoplasty plus the superficial code, because that turbinate cautery matches its descriptor
    • C.Report the septoplasty plus a hemorrhage-control code, because the cautery was done to stop bleeding
    • D.Report the septoplasty plus the intramural code, because it is the more extensive of the turbinate codes

    NCCI states that the turbinate cautery codes are for reducing turbinate size and are not reported for access or for control of intraoperative bleeding with other nasal procedures. Hemorrhage-control codes are barred for the same reason: bleeding caused by the operation is part of the operation.

    Ref QB-CJGTK5Source: CMS NCCI Policy Manual for Medicare, Chapter V (Surgery: Respiratory, Cardiovascular, Hemic and Lymphatic Systems): turbinate cautery codes 30801 and 30802 and control of bleedingReport a problem with this question

  3. 3. With computer-assisted navigation, a pulmonologist performs a bronchoscopy, takes a transbronchial lung biopsy in the right lower lobe, and performs a bronchoalveolar lavage in the right middle lobe. The relevant services are 31622 (diagnostic), 31624 (lavage), 31628 (transbronchial biopsy) and +31627 (navigation). What is reported?

    • A.The lavage, the biopsy and the navigation add-on, with the diagnostic bronchoscopy left unreported✓ Answer
    • B.The diagnostic bronchoscopy, the lavage and the biopsy, with navigation absorbed into the scope work
    • C.The diagnostic bronchoscopy and the navigation add-on, with the lavage and biopsy absorbed by the scope
    • D.The biopsy and the navigation add-on, with the lavage absorbed as the washing step of the same scope

    A surgical bronchoscopy includes the diagnostic bronchoscopy, so 31622 falls away. Lavage and transbronchial biopsy are distinct surgical services at different sites and each is reported, and navigation is an add-on listed in addition to the primary bronchoscopy rather than a stand-alone code.

    Ref QB-U2BNZ4Source: AMA CPT guidelines and parentheticals for Endoscopy, Trachea and Bronchi (surgical bronchoscopy includes diagnostic bronchoscopy; navigation is an add-on service); CMS NCCI Policy Manual for Medicare, Chapter V (Surgery: Respiratory, Cardiovascular, Hemic and Lymphatic Systems)Report a problem with this question

  4. 4. A physician drains a pleural effusion by needle under real-time ultrasound and then orders a chest x-ray to confirm no pneumothorax. Thoracentesis is 32554 without imaging guidance and 32555 with imaging guidance; 76942 is ultrasound guidance and 71046 is a two-view chest x-ray. Under NCCI policy, what does this physician report?

    • A.32555 plus 76942, because the descriptor covers imaging in general but not the ultrasound itself
    • B.32555 plus 71046, because the confirming film is a distinct study done after the procedure ended
    • C.32554 plus 76942, because guidance is always listed apart from the needle procedure it assists
    • D.32555 by itself, because guidance is in the descriptor and the confirming film is not separate✓ Answer

    Imaging guidance named in a code descriptor is not billed again, so the with-imaging thoracentesis code replaces the pair of a no-imaging code plus guidance. NCCI also states that a chest radiologic examination confirming adequacy or lack of complications after thoracentesis is not reported separately.

    Ref QB-BJ5GE4Source: AMA CPT descriptors for thoracentesis with imaging guidance (32555); CMS NCCI Policy Manual for Medicare, Chapter V (Surgery: Respiratory, Cardiovascular, Hemic and Lymphatic Systems): chest radiologic examination after thoracentesisReport a problem with this question

  5. 5. During an open right lobectomy the surgeon places a right chest tube at closure. In the same session the patient develops a left hemothorax, and the surgeon places a left chest tube as well. Tube thoracostomy (32551) carries the 'separate procedure' designation. Under NCCI policy, how are the tubes handled?

    • A.Both tubes are reportable with modifier 50 because the same tube procedure was done on each side of the chest
    • B.The right tube is reportable with the proper modifier because it is a distinct step, and the left tube is included too
    • C.The left tube is reportable with the proper modifier because that cavity was not entered, and the right tube is included✓ Answer
    • D.Both tubes are included because the designation bars the code at any encounter involving open thoracic surgery

    A 'separate procedure' is not reported when it is part of another service in the same area. NCCI applies this to tube thoracostomy with an open thoracic procedure unless the tube is placed in the cavity contralateral to the one entered, which is why only the side away from the thoracotomy is reportable.

    Ref QB-T2YAU3Source: CMS NCCI Policy Manual for Medicare, Chapter V (Surgery: Respiratory, Cardiovascular, Hemic and Lymphatic Systems): tube thoracostomy 32551 designated as a separate procedure with open thoracic proceduresReport a problem with this question

  6. 6. A patient has a dual-chamber pacemaker with atrial and ventricular leads. The surgeon opens the pocket, repairs the insulation of the atrial lead (33218), and because the battery is near depletion replaces the generator with a new one connected to both existing leads. Generator replacement is 33227 single, 33228 dual and 33229 multiple lead system; generator removal alone is 33233. How is the session reported?

    • A.Report the dual replacement code plus generator removal, because the lead repair is included in it
    • B.Report the single-lead replacement code plus the lead repair, because only one lead was worked on
    • C.Report the dual replacement code plus the lead repair, because a new device joins two connected leads✓ Answer
    • D.Report the lead repair plus generator removal, because the repair code already covers reinsertion

    Generator replacement is chosen by the number of leads connected to the device and already includes removing the old generator, so the removal code is never added. NCCI says lead repair includes opening the pocket and reinserting the original device, but when a new device goes in, a replacement code may be reported in addition.

    Ref QB-AJS593Source: CMS NCCI Policy Manual for Medicare, Chapter V (Surgery: Respiratory, Cardiovascular, Hemic and Lymphatic Systems): lead repair codes 33218 and 33220 with replacement codes 33227-33229; AMA CPT Pacemaker or Implantable Defibrillator guidelinesReport a problem with this question

  7. 7. A child who turned 5 last week has a catheter placed through the internal jugular vein, tunneled under the skin, and attached to a subcutaneous port in the chest. In CPT's central venous access table, these insertion codes split at younger than 5 years versus age 5 and older. Which row of the table applies?

    • A.Centrally inserted, tunneled, without port or pump, patient age 5 years or older
    • B.Centrally inserted, tunneled, with subcutaneous port, patient age 5 years or older✓ Answer
    • C.Peripherally inserted, tunneled, with subcutaneous port, patient age 5 years or older
    • D.Centrally inserted, tunneled, with subcutaneous port, patient younger than 5 years

    The jugular entry makes the device centrally inserted, the subcutaneous port rather than a simple exit site separates it from a tunneled catheter without a port, and a child who has reached the fifth birthday falls in the 5-and-older row. Each element of the table must be read from the documentation.

    Ref QB-S2MYN2Source: AMA CPT Central Venous Access Procedures guidelines and table (entry site, tunneling, port or pump, patient age)Report a problem with this question

  8. 8. A patient's tunneled central venous catheter, without a port, entered through the right jugular vein and has become nonfunctional. The physician removes it and places a new tunneled catheter through the left jugular vein at the same session. Under CPT guidelines, how is this reported?

    • A.Report a complete replacement code alone, because a new catheter took the place of the old device
    • B.Report a repair code plus a new insertion, because the old device was serviced before the new one went in
    • C.Report a removal code plus a new insertion, because the new device uses a separate venous access site✓ Answer
    • D.Report a partial replacement code alone, because just the catheter was changed and no port is present

    A replacement code describes an exchange through the same venous access. CPT directs that when an existing device is removed and a new one is placed through a separate venous access site, codes for both the removal and the new insertion are reported.

    Ref QB-HJ9GFBSource: AMA CPT Central Venous Access Procedures guidelines (removal of an existing device with a new device placed through a separate venous access site)Report a problem with this question

  9. 9. Through a femoral artery puncture, a catheter is advanced from the aorta into the celiac trunk (first order), then the common hepatic artery (second order), then the proper hepatic artery (third order), all in one vascular family and along one path. Under CPT guidelines, how is the catheter placement reported?

    • A.One non-selective aortic code plus a third-order code, because the catheter began its course in the aorta
    • B.One third-order code, because it includes the introduction and the lesser orders along the approach✓ Answer
    • C.One code for each order, because each vessel entered is a distinct selective catheter placement in itself
    • D.One first-order code, because the family is named for the first branch the catheter enters from the aorta

    Selective catheterization is coded to the highest order reached in a vascular family, and that code includes the introduction and every lesser-order placement used on the way. Separate coding of lower orders or of an aortic non-selective placement along the same path would double-count the approach.

    Ref QB-Z24BVASource: AMA CPT Vascular Injection Procedures guidelines (selective catheterization includes introduction and all lesser-order selective catheterization used in the approach)Report a problem with this question

  10. 10. In one leg, a physician performs radiofrequency ablation of the great saphenous vein and then of the small saphenous vein through a separate access site, using ultrasound guidance throughout. The codes are 36475 (first vein treated) and +36476 (subsequent vein in the same extremity through a separate access site); 76942 is ultrasound guidance. What is reported?

    • A.The first-vein code twice with modifier 59, because each vein is a separate target with its own access
    • B.The first-vein code, the subsequent-vein add-on and ultrasound guidance, because imaging is a distinct service
    • C.The first-vein code plus ultrasound guidance, because all veins of one leg count as one treated territory
    • D.The first-vein code plus the subsequent-vein add-on, because guidance is included in those two codes✓ Answer

    The ablation codes include vascular access and imaging guidance and monitoring, and the CPT parenthetical bars reporting them with ultrasound guidance. The second vein in the same extremity through a separate access is described by the add-on, so the first-vein code is not repeated.

    Ref QB-Z6RHPNSource: AMA CPT descriptors and parentheticals for endovenous radiofrequency ablation (36475 and +36476)Report a problem with this question

  11. 11. A surgeon grafts the left internal mammary artery to the LAD and places two saphenous vein grafts from a leg harvest. CPT offers a venous-only family, an arterial family, and a combined arterial-venous add-on family that is used with the arterial family. How is the surgery coded?

    • A.One venous-only code for three grafts plus a harvest code for the leg, since the mammary pedicle needs no harvest
    • B.One arterial code for one graft plus one venous-only code for two grafts, each family counting its own conduit
    • C.One arterial code for one graft plus one arterial-venous add-on for two vein grafts, with the harvest included✓ Answer
    • D.One arterial code for three grafts plus a vein harvest add-on for the leg, since an artery was the primary conduit

    NCCI states that combined bypasses take one code from the arterial-venous family plus one arterial code, while the venous-only family is reserved for operations with no arterial graft. Harvest of the saphenous vein is included, so no vein-harvest or vein-ligation code is added.

    Ref QB-HPWP9PSource: CMS NCCI Policy Manual for Medicare, Chapter V (Surgery: Respiratory, Cardiovascular, Hemic and Lymphatic Systems): coronary artery bypass code selection; AMA CPT Coronary Artery Bypass guidelinesReport a problem with this question

  12. 12. For dialysis access, a surgeon exposes the radial artery and cephalic vein at the wrist, divides the vein, and sews it directly to the adjacent artery. The vein is not tunneled or moved along its length, and no graft material is used. Which type of hemodialysis access does CPT call this?

    • A.A vein transposition, since the vein is mobilized and redirected to reach the artery
    • B.A direct arteriovenous anastomosis, since the vein is joined to the adjacent artery✓ Answer
    • C.A nonautogenous graft, since the access must be cannulated repeatedly at dialysis
    • D.An autogenous graft, since the conduit used for the access is the patient's own vein

    CPT separates hemodialysis access by construction: a direct anastomosis joins an adjacent vein and artery, a transposition relocates a named vein along its course, and a graft interposes a separate conduit. With no relocation and no conduit, this wrist fistula is the direct type.

    Ref QB-Y6D7HMSource: AMA CPT Hemodialysis Access, Intervascular Cannulization and Shunt descriptors (direct arteriovenous anastomosis versus vein transposition and grafts)Report a problem with this question

  13. 13. Through a small incision a surgeon removes one enlarged deep axillary lymph node to establish a diagnosis, leaving the remaining nodes and axillary fat in place. Which service category in the CPT lymph node section fits this operation?

    • A.Open biopsy or excision of a deep axillary node, as one discrete node was taken for diagnosis✓ Answer
    • B.Open biopsy or excision of a superficial node, as the incision was small and easily closed
    • C.Axillary lymphadenectomy, superficial, as a node was removed from the axillary basin itself
    • D.Axillary lymphadenectomy, complete, as the deep level of the axilla was entered and sampled

    A lymphadenectomy removes a node-bearing tissue group, while biopsy or excision takes a discrete node. Depth, not incision size, separates the superficial and deep biopsy codes, so one deep axillary node removed for diagnosis belongs in the deep-node biopsy or excision category.

    Ref QB-GPJC4NSource: AMA CPT Lymph Nodes and Lymphatic Channels descriptors (biopsy or excision of lymph node versus limited and radical lymphadenectomy)Report a problem with this question

  14. 14. Through a single site on the right iliac crest, a hematologist performs a diagnostic bone marrow aspiration and a bone marrow core biopsy at one encounter. The codes are 38220 (aspiration), 38221 (biopsy), 38222 (biopsy and aspiration) and 20220 (bone biopsy). Under NCCI policy, what is reported?

    • A.38222 as one code, because the aspiration and biopsy took place in the same iliac bone✓ Answer
    • B.38221 plus 20220, because the core sample contains both marrow tissue and fragments of bone
    • C.38221 as one code, because the aspiration is absorbed and no combined code applies to one bone
    • D.38220 plus 38221 with modifier 59, because two distinct techniques were used on the iliac bone

    NCCI directs that aspiration and biopsy on the same iliac bone are reported with the combined code. The two single-technique codes may be paired only when each is performed without the other technique on different bones or at separate encounters, and the marrow biopsy code is not reported with a bone biopsy code.

    Ref QB-37F72RSource: CMS NCCI Policy Manual for Medicare, Chapter V (Surgery: Respiratory, Cardiovascular, Hemic and Lymphatic Systems): diagnostic bone marrow aspiration and biopsy codes 38220, 38221 and 38222Report a problem with this question

  15. 15. A patient was 11 when an adenotonsillectomy was scheduled and turned 12 a week before the surgery date. Both tonsils and the adenoids are removed. CPT splits the combined code at younger than age 12 (42820) versus age 12 or over (42821). Which reporting is correct?

    • A.The age-12-or-over tonsil code plus an adenoid code, because each structure has its own code
    • B.The age-12-or-over combined code once, using the age on the date the surgery was performed✓ Answer
    • C.The age-12-or-over combined code with modifier 50, because both tonsils were removed that day
    • D.The younger-than-12 combined code once, using the age on the date the surgery was scheduled

    The age on the date of service selects the code, and the scheduling date has no bearing on it. The combined code already describes the tonsils and adenoids together and is inherently bilateral, so neither stand-alone codes nor modifier 50 are added.

    Ref QB-KPMCMRSource: AMA CPT Pharynx, Adenoids and Tonsils descriptors (42820, 42821 age split)Report a problem with this question

  16. 16. During an EGD a gastroenterologist takes a cold-forceps biopsy of an antral ulcer and separately removes a duodenal polyp by snare. The relevant codes are 43235 (diagnostic), 43239 (with biopsy) and 43251 (with snare removal). For a claim following NCCI policy, how is the session reported?

    • A.The snare code and the biopsy code with modifier 59, because the biopsy was of a separate lesion✓ Answer
    • B.The diagnostic code, the biopsy code and the snare code, because each one marks a step of the session
    • C.The snare code alone, because a removal absorbs any biopsy done during the same endoscopic session
    • D.The biopsy code twice, because the ulcer and the polyp were each sampled or removed by forceps or snare

    A surgical endoscopy includes the diagnostic endoscopy, and a biopsy of a lesion that is then removed is not reported. A biopsy of a different lesion is a distinct service, so NCCI allows both surgical codes when a modifier such as 59 or XS documents the separate lesion.

    Ref QB-274VUPSource: CMS NCCI Policy Manual for Medicare, Chapter VI (Surgery: Digestive System): endoscopic services and biopsy of a lesion separate from one removedReport a problem with this question

  17. 17. For suspected choledocholithiasis, a gastroenterologist performs an ERCP and sweeps the bile duct with a balloon catheter, but no stones or debris are found and no other intervention is done. The codes include 43260 (diagnostic ERCP) and 43264 (ERCP with removal of calculi or debris). How is the service reported?

    • A.The ERCP reported as stone removal with modifier 52, because the sweep recovered no stone at all
    • B.The ERCP reported as a biopsy, because the balloon sweep sampled the duct contents
    • C.The ERCP reported as stone removal, because the balloon sweep of the duct was the work carried out
    • D.The ERCP reported as diagnostic, because no calculi or debris were found despite the balloon✓ Answer

    CPT instructs coders not to report the stone-removal ERCP if no calculi or debris are found, even when a balloon catheter is deployed. With no other therapeutic service performed, the procedure is the diagnostic ERCP, and a reduction modifier cannot convert a removal that never occurred.

    Ref QB-JP92FQSource: AMA CPT parenthetical at ERCP with removal of calculi or debris (43264); AMA CPT Endoscopic Retrograde Cholangiopancreatography guidelinesReport a problem with this question

  18. 18. A laparoscopic cholecystectomy cannot be completed because of dense adhesions. The surgeon converts to a laparotomy, explores the abdomen through that incision, and removes the gallbladder. Under NCCI policy, what is reported?

    • A.The open cholecystectomy plus exploratory laparotomy, because the abdomen was fully explored first
    • B.The laparoscopic cholecystectomy with modifier 53 plus the open code, because both were attempted
    • C.The open cholecystectomy by itself, because the failed laparoscopy and exploration are not separate✓ Answer
    • D.The open cholecystectomy plus diagnostic laparoscopy, because the scope first showed the adhesions

    NCCI states that when a laparoscopic procedure is converted to open, only the open procedure may be reported, and neither a surgical nor a diagnostic laparoscopy code is added. Exploratory laparotomy is likewise not separately reportable with an open abdominal procedure.

    Ref QB-576VCTSource: CMS NCCI Policy Manual for Medicare, Chapter VI (Surgery: Digestive System): laparoscopic procedure converted to open; exploratory laparotomy 49000 with open abdominal proceduresReport a problem with this question

  19. 19. A surgeon performs a laparoscopic cholecystectomy and injects contrast through the cystic duct for an intraoperative cholangiogram; the images show a clear duct and the common bile duct is not opened. The codes are 47562 (cholecystectomy), 47563 (with cholangiography) and 47564 (with exploration of the common duct). Setting aside any radiology supervision and interpretation, which surgical coding is correct?

    • A.The plain cholecystectomy code plus a separate cholangiography injection code for the contrast study
    • B.The cholangiography cholecystectomy code alone, because the descriptor already names the study✓ Answer
    • C.The plain cholecystectomy code plus a diagnostic laparoscopy code for the look at the biliary tree
    • D.The common-duct exploration cholecystectomy code, because the duct was evaluated during the case

    Because the descriptor combines the cholecystectomy with cholangiography, one code captures both, and a surgical laparoscopy already includes diagnostic laparoscopy. The exploration code requires that the common duct actually be explored, and viewing it on a cholangiogram does not meet that requirement.

    Ref QB-NPB2YTSource: AMA CPT Laparoscopy, Biliary Tract descriptors (47562, 47563, 47564)Report a problem with this question

  20. 20. A surgeon repairs two initial, reducible anterior abdominal wall hernias laparoscopically with mesh; the defects measure 2.0 cm and 1.5 cm and are separated by more than 10 cm of intact fascia. CPT bands these repairs as less than 3 cm, 3 to 10 cm, and greater than 10 cm, using total defect size (the sum of the individual defects when they are 10 cm or more apart), with separate codes for reducible and incarcerated-or-strangulated hernias. Which reporting is correct?

    • A.The 3 to 10 cm reducible code once, because defect lengths are summed and mesh placement is included✓ Answer
    • B.The less-than-3 cm reducible code once, because the largest single defect sets the band for the case
    • C.The less-than-3 cm reducible code twice, because each defect is under 3 cm and was repaired separately
    • D.The 3 to 10 cm reducible code once plus a mesh implantation code, because mesh is not in the descriptor

    These codes are reported once per session based on the total defect size, so 2.0 cm plus 1.5 cm gives 3.5 cm and the middle band. The same codes apply to open, laparoscopic and robotic approaches, and mesh implantation is included rather than reported with an additional code.

    Ref QB-ACF3WASource: AMA CPT Anterior Abdominal Hernia Repair guidelines (total defect size, reported once, any approach, mesh included)Report a problem with this question

  21. 21. At one open session a surgeon repairs two recurrent anterior abdominal wall hernias: a reducible 4 cm defect and an incarcerated 7 cm defect, separated by more than 10 cm of intact fascia. CPT sets size bands of less than 3 cm, 3 to 10 cm, and greater than 10 cm, based on total defect size, and has separate families for initial and recurrent repairs. How is the session reported?

    • A.Once as initial, greater than 10 cm, incarcerated, because neither defect had a repair at this same site
    • B.Once as recurrent, greater than 10 cm, incarcerated, because mixed defects take the incarcerated code✓ Answer
    • C.Twice as recurrent, 3 to 10 cm, one reducible and one incarcerated, because each defect has its own status
    • D.Once as recurrent, greater than 10 cm, reducible, because the reducible defect was treated first

    Because the defects are separated by more than 10 cm of intact fascia, total size is their sum, 4 cm plus 7 cm, or 11 cm, and these codes are reported only once per session. When both reducible and incarcerated or strangulated defects are repaired together, CPT treats the whole repair as incarcerated-strangulated, and the stem documents recurrence so the recurrent family applies.

    Ref QB-SU9WAASource: AMA CPT Anterior Abdominal Hernia Repair guidelines (initial versus recurrent, reducible versus incarcerated or strangulated, total defect size)Report a problem with this question

  22. 22. At one encounter a surgeon places rubber bands on two internal hemorrhoid columns, surgically excises a third column, and drains a small abscess arising within that excised hemorrhoid. Under NCCI policy, what is reported?

    • A.The excision and the abscess drainage, with modifier 59 on drainage, because an abscess is a new lesion
    • B.The excision and the banding, with modifier 59 on banding, because different columns were treated
    • C.The excision, the banding and the drainage, with modifier 51 on the last two, because all were needed
    • D.The excision by itself, because one most-extensive code covers hemorrhoid treatment and this drainage✓ Answer

    NCCI allows only the code describing the most extensive procedure when multiple services treat hemorrhoids at one encounter. Draining an abscess during hemorrhoid treatment is also not separately reportable unless the abscess is at a separate site unrelated to the hemorrhoids, and this one arose in the excised hemorrhoid.

    Ref QB-9C4RQ9Source: CMS NCCI Policy Manual for Medicare, Chapter VI (Surgery: Digestive System): multiple services used to treat hemorrhoids at the same patient encounterReport a problem with this question

  23. 23. A surgeon performs a laparoscopic gastric bypass with a 120 cm Roux limb, preceded by a brief diagnostic laparoscopy, and at the end passes an endoscope to leak-test the anastomosis. CPT describes 43644 (gastric bypass, Roux limb of 150 cm or less) and 43645 (gastric bypass with small intestine reconstruction to limit absorption). No other finding is treated. How is the surgery reported?

    • A.43644 plus the diagnostic laparoscopy, because that survey came before the bypass was begun
    • B.43645 alone, because every Roux reconstruction limits absorption and so the descriptor is met
    • C.43644 plus the endoscopy code, because the scope leak test is a different type of procedure
    • D.43644 alone, because the limb is within 150 cm and the look and leak test are not separate✓ Answer

    The documented limb length fits the 150 cm or less descriptor. A surgical laparoscopy includes diagnostic laparoscopy, and NCCI does not allow separate reporting of an endoscopy performed at the same encounter to verify that an operation was done correctly or that no injury occurred.

    Ref QB-RUWJ59Source: AMA CPT Laparoscopy, Stomach descriptor and parenthetical for gastric bypass (43644); CMS NCCI Policy Manual for Medicare, Chapter VI (Surgery: Digestive System): endoscopy to confirm no intraoperative injuryReport a problem with this question

  24. 24. For a Medicare claim: a fully prepped patient is scheduled for a diagnostic colonoscopy. With the scope at the hepatic flexure, the patient becomes hypotensive and the physician stops before reaching the cecum. No biopsy or other therapy was done. How is the procedure reported?

    • A.The colonoscopy code without a modifier, because the scope traveled beyond the splenic flexure
    • B.The colonoscopy code with modifier 52, because the physician elected to do less than a full exam
    • C.The colonoscopy code with modifier 53, because an unforeseen patient risk ended the procedure✓ Answer
    • D.The sigmoidoscopy code without a modifier, because the scope did not arrive at the cecum at all

    Modifier 53 reports a procedure the physician discontinued because of circumstances threatening the patient, and Medicare guidance uses it for an interrupted colonoscopy in a prepped patient. The older splenic-flexure shortcut does not decide this: a complete colonoscopy reaches the cecum, and this scheduled colonoscopy did not.

    Ref QB-8CRDJ8Source: CMS Medicare guidance on an interrupted colonoscopy (modifier 53); AMA CPT Colonoscopy guidelines for a procedure stopped short of the cecum because of unforeseen circumstancesReport a problem with this question

  25. 25. Under CPT guidelines: a patient with an adequate bowel prep is scheduled for a total colonoscopy. A sigmoid polyp is removed by snare (45385), but a tortuous, looping colon prevents the scope from advancing past the hepatic flexure, so the cecum is never reached. How is the procedure reported?

    • A.The snare sigmoidoscopy code without a modifier, because the polyp lay in the sigmoid colon
    • B.The snare colonoscopy code with modifier 53, because any exam short of the cecum is stopped
    • C.The snare colonoscopy code without a modifier, because the polyp removal itself was completed
    • D.The snare colonoscopy code with modifier 52, because a therapeutic exam fell short of the cecum✓ Answer

    CPT defines colonoscopy as examination to the cecum, and when a therapeutic colonoscopy in a patient prepared for the full exam does not reach it, the therapeutic colonoscopy code is reported with modifier 52. The polyp's location does not turn a scheduled and prepared colonoscopy into a sigmoidoscopy.

    Ref QB-QUJ8Y7Source: AMA CPT Colonoscopy guidelines (a therapeutic colonoscopy that does not reach the cecum is reported with modifier 52)Report a problem with this question

  26. 26. During a laparoscopic cholecystectomy, the surgeon finds an acutely inflamed appendix and removes it laparoscopically (44970); pathology confirms appendicitis. On a claim following NCCI policy, how is the appendectomy handled?

    • A.It is bundled, because laparoscopic procedures through the same ports count as one approach
    • B.It is reportable, because a diseased appendix makes the removal a medically necessary service✓ Answer
    • C.It is reportable only as open, because the laparoscopic code cannot pair with another scope code
    • D.It is bundled, because any appendectomy during another abdominal procedure counts as incidental

    NCCI allows the laparoscopic appendectomy code with another laparoscopic procedure when a diseased appendix is removed. Only an incidental appendectomy of a normal appendix is excluded, so the pathology-confirmed inflammation makes this service reportable.

    Ref QB-7CD3D7Source: CMS NCCI Policy Manual for Medicare, Chapter VI (Surgery: Digestive System): medically necessary versus incidental appendectomy; laparoscopic appendectomy 44970Report a problem with this question

  27. 27. In the operating room, a surgeon first passes a flexible laryngoscope to survey the airway, then performs a direct laryngoscopy and biopsies a lesion on the left vocal fold. Under NCCI policy, how is the encounter reported?

    • A.Flexible laryngoscopy only, as the first scope passed
    • B.Direct laryngoscopy with biopsy only, flexible not coded✓ Answer
    • C.Both laryngoscopies, with modifier 59 on the flexible one
    • D.Both laryngoscopies, with modifier 51 on the flexible one

    NCCI policy states that flexible laryngoscopy and direct laryngoscopy shall not be reported for the same patient encounter, so only the definitive operative service, the direct laryngoscopy with biopsy, is coded. Adding modifier 59 or 51 does not unbundle a pair the policy says is never reported together.

    Ref QB-PU7WS6Source: CMS NCCI Policy Manual for Medicare, Chapter V (CPT codes 30000-39999), Respiratory System, item 8: flexible laryngoscopy and direct laryngoscopy shall not be reported for the same patient encounterReport a problem with this question

  28. 28. A surgeon performs a partial laryngectomy for glottic cancer and, at the same session, a planned tracheostomy to protect the airway during healing. The planned tracheostomy code (31600) carries the 'separate procedure' designation. Under NCCI policy, how is the tracheostomy handled?

    • A.Reported with modifier 51 as a second procedure
    • B.Reported with modifier 59 as a distinct procedure
    • C.Captured by modifier 22 on the laryngectomy code
    • D.Not reported, as it is included in the laryngectomy✓ Answer

    Under the CMS 'separate procedure' policy, a code with that designation is not reported when it is performed as part of a related, more extensive procedure in the same area. NCCI names laryngotomy, laryngectomy and laryngoplasty as laryngeal surgeries that frequently require a tracheostomy, so the planned tracheostomy is included rather than added with 51, 59 or 22.

    Ref QB-6C2R76Source: CMS NCCI Policy Manual for Medicare, Chapter V (CPT codes 30000-39999), Respiratory System, item 12: 31600 'separate procedure' designation; tracheostomy not separately reportable with laryngotomy, laryngectomy or laryngoplastyReport a problem with this question

  29. 29. A surgeon performs a diagnostic thoracoscopy to evaluate a loculated pleural effusion. The findings show a thick fibrous peel that cannot be managed through the scope, so the surgeon decides to open the chest and performs an open decortication. Under NCCI policy, what is reported?

    • A.The diagnostic thoracoscopy and the open decortication✓ Answer
    • B.The open decortication only, with the scope as a scout look
    • C.The open decortication and a surgical thoracoscopy code
    • D.The diagnostic thoracoscopy only, with modifier 22 added

    NCCI allows a diagnostic thoracoscopy to be reported with an open thoracotomy when the thoracoscopy findings lead to the decision to open the chest. It is bundled only when it is a scout look to assess the surgical field of an open procedure already planned, and when a surgical thoracoscopy is converted to open, neither scope code is reported.

    Ref QB-NUUJM5Source: CMS NCCI Policy Manual for Medicare, Chapter V (CPT codes 30000-39999), Respiratory System, item 15: diagnostic thoracoscopy separately reportable when its findings lead to the decision to perform an open thoracotomy; scout and converted thoracoscopy rulesReport a problem with this question

  30. 30. During one VATS session, a surgeon wedge-resects a nodule in the right lower lobe and a nodule in the right upper lobe for frozen section. The upper-lobe nodule is carcinoma, so the surgeon completes a right upper lobectomy; the lower lobe is left in place. Under NCCI policy, which services are reported?

    • A.The lobectomy only, as both wedges were in the same chest
    • B.The lobectomy plus both wedges, as frozen section set the extent
    • C.The lobectomy plus the lower-lobe wedge, not the upper-lobe one✓ Answer
    • D.The lobectomy plus the upper-lobe wedge, with modifier 58

    NCCI bundles a lung biopsy taken from tissue that the more extensive procedure then removes, whatever the approach or technique and even when frozen section decided the extent of surgery. A biopsy from a location the lobectomy does not remove, here the retained lower lobe, remains separately reportable.

    Ref QB-7AFWC7Source: CMS NCCI Policy Manual for Medicare, Chapter V (CPT codes 30000-39999), Respiratory System, item 21: diagnostic lung biopsy from a location removed by segmentectomy or lobectomy (open or VATS) not separately reportable; biopsy outside the resected area is reportableReport a problem with this question

  31. 31. A physician attempts to dilate an esophageal stricture by passing bougies without an endoscope, but the dilators will not pass. At the same session, an EGD is performed and the stricture is dilated with a balloon through the scope. Under NCCI policy, what is reported?

    • A.Both dilations, with modifier 59 on the bougie dilation
    • B.The EGD balloon dilation only; the failed one is not coded✓ Answer
    • C.Both dilations, with modifier 53 on the failed bougie one
    • D.The bougie dilation only, as the first technique tried

    NCCI states that when a non-endoscopic esophageal dilation fails and is followed by an endoscopic dilation, only the endoscopic dilation may be reported and the failed procedure is not reported. Modifier 53 or 59 cannot be used to bill the attempt, because the policy excludes the failed service itself.

    Ref QB-QSM3Y7Source: CMS NCCI Policy Manual for Medicare, Chapter VI (CPT codes 40000-49999), Endoscopic Services, item 7: failed non-endoscopic esophageal dilation followed by endoscopic dilation, only the endoscopic dilation is reportedReport a problem with this question

  32. 32. During a colonoscopy, the physician balloon-dilates one stricture in the sigmoid colon and a second, separate stricture in the transverse colon. Under NCCI policy, how many units of the colonoscopy-with-dilation code are reported?

    • A.One unit, covering every stricture dilated✓ Answer
    • B.Two units, one for each stricture dilated
    • C.One unit, plus a second line with modifier XS
    • D.Two units, with modifier 76 on the second

    The GI endoscopy dilation codes describe dilation of stricture(s), so one unit includes every stricture dilated during that endoscopy. NCCI says these codes shall not be reported with more than one unit when more than one stricture is dilated, and a second line with XS or 76 would be the same over-reporting.

    Ref QB-8AT8J8Source: CMS NCCI Policy Manual for Medicare, Chapter VI (CPT codes 40000-49999), Endoscopic Services, item 4: GI endoscopy dilation codes (e.g., 43213, 45340, 45386) include all strictures dilated and are not reported with more than one unit of serviceReport a problem with this question

  33. 33. For hoarseness and dysphagia, a physician performs a medically necessary flexible laryngoscopy with a separate laryngoscope to examine a vocal fold lesion, then performs a diagnostic EGD with a gastroscope at the same encounter. Under NCCI policy, how is this reported?

    • A.The EGD only, since the larynx lies on the scope's path
    • B.The laryngoscopy only, as the first scope that was used
    • C.Both codes, with no modifier needed on either one
    • D.Both codes, with an NCCI-associated modifier on one✓ Answer

    If the larynx is only viewed through the esophagoscope or upper GI endoscope, no laryngoscopy code is reported. When a medically necessary laryngoscopy is done with a separate laryngoscope, NCCI allows both codes, but because the pair is an edit they are reported with an NCCI PTP-associated modifier.

    Ref QB-RSYD59Source: CMS NCCI Policy Manual for Medicare, Chapter VI (CPT codes 40000-49999), Endoscopic Services, item 15: larynx viewed through an esophagoscope or EGD scope is not reported; laryngoscopy with a separate laryngoscope may be reported with NCCI PTP-associated modifiersReport a problem with this question

  34. 34. Op note: chronic rhinosinusitis with nasal polyps, left side only. Under general anesthesia the surgeon passes a 0-degree endoscope into the left nasal cavity and surveys the middle meatus. One polyp is biopsied and sent for permanent pathology; the surgeon does not wait for the result. The surgeon then opens the ethmoid bulla, clears the anterior ethmoid cells, takes down the basal lamella, and removes diseased mucosa and polyps from the posterior ethmoid cells. The frontal recess and frontal sinus are not entered. The right side is not operated on. Available codes: 31231 diagnostic nasal endoscopy (separate procedure); 31237 surgical nasal/sinus endoscopy with biopsy, polypectomy or debridement; 31253 endoscopic total ethmoidectomy with frontal sinus exploration and tissue removal; 31254 endoscopic partial (anterior) ethmoidectomy; 31255 endoscopic total (anterior and posterior) ethmoidectomy. Which code(s) should be reported?

    • A.31253-LT
    • B.31254-LT
    • C.31255-LT✓ Answer
    • D.31255-50

    The surgeon cleared both the anterior and the posterior ethmoid cells without working in the frontal sinus, which is the total ethmoidectomy described by 31255. Sinus endoscopy codes are unilateral, so a left-only procedure takes -LT. 31254-LT undercodes, since it covers only the anterior cells. 31253-LT requires frontal sinus exploration with tissue removal, and the frontal recess was not entered. 31255-50 reports both sides when only the left was operated on. The polyp biopsy (31237) and the endoscopic survey (31231) are not added: NCCI says a biopsy taken during a more extensive sinus procedure is not separately reportable unless the decision to do that procedure rests on its pathology result, and evaluating the access region is part of every respiratory endoscopy.

    Ref QB-5AR825Source: CMS NCCI Policy Manual for Medicare Services (rev. 1/1/2026), Ch. V §C.2 (biopsy with a more extensive nasal/sinus procedure not separately reportable; example 31237 with 31255) and §C.3 (evaluation of access regions, e.g., diagnostic nasal endoscopy, not reported with surgical endoscopy)Report a problem with this question

  35. 35. A 74-year-old with symptomatic complete heart block has no existing cardiac device. Through a left subclavian venous approach, the cardiologist uses ultrasound guidance to puncture the vein and fluoroscopy to position the leads. A right atrial lead and a right ventricular lead are placed and connected to a new dual-chamber pacemaker generator in a pre-pectoral pocket, and the device is programmed before closure. For a Medicare claim, available codes: 33206 new permanent pacemaker system with atrial lead; 33208 new permanent pacemaker system with atrial and ventricular leads; 33213 pacemaker generator only, with existing dual leads; 33217 insertion of 2 transvenous electrodes; 76937 ultrasound guidance for vascular access (add-on). Which code(s) should be reported?

    • A.33208 only✓ Answer
    • B.33208, 76937
    • C.33208, 33217
    • D.33213 only

    33208 is a system code: it covers the new generator and both the atrial and ventricular leads, so adding 33217 for the two leads unbundles the system. 33213 is the generator-only code for a patient whose dual leads are already in place, and this patient had no leads. 33208 with 76937 fails because NCCI bars reporting ultrasound guidance codes (76937 is named) and fluoroscopy with pacemaker and defibrillator procedures 33202-33275. Device programming at implant is also integral and not reported separately.

    Ref QB-NSWDM5Source: CMS NCCI Policy Manual for Medicare Services (rev. 1/1/2026), Ch. V §D.21 (fluoroscopy and ultrasound guidance, including 76937, not separately reportable with 33202-33275) and §D.22 (interrogation and programming integral to pacemaker insertion)Report a problem with this question

  36. 36. For a Medicare claim: a 68-year-old inpatient needs central venous access. The physician first attempts a non-tunneled right internal jugular central line but cannot pass the guidewire and abandons it. At the same session, using a palpable left basilic vein and no imaging guidance, the physician inserts a peripherally inserted central catheter with no port or pump. A portable single-view chest x-ray afterward confirms the catheter tip at the cavoatrial junction. Available codes: 36556 non-tunneled centrally inserted central venous catheter, age 5 or older; 36569 PICC without port or pump, without imaging guidance, age 5 or older; 36573 PICC without port or pump, including all imaging guidance, age 5 or older; 71045 chest x-ray, single view. Which code(s) should be reported?

    • A.36573 only
    • B.36569, 71045
    • C.36569, 36556
    • D.36569 only✓ Answer

    The completed device is a PICC with no port or pump placed without imaging guidance in an adult, which is 36569. 36569 with 36556 fails because NCCI says that when one catheter insertion is not completed and another is then inserted at the same encounter, only the completed procedure is reported. 36569 with 71045 fails because the confirming chest x-ray after a central venous catheter is integral to the insertion under NCCI. 36573 is the PICC code for an insertion guided by imaging; a film taken after placement only checks tip position and did not guide the insertion, which the note says was done by palpation.

    Ref QB-6A4K76Source: CMS NCCI Policy Manual for Medicare Services (rev. 1/1/2026), Ch. V §D.31 (if one catheter insertion is not completed and another is inserted at the same encounter, only the completed procedure is reported) and §D.36 (confirmatory chest x-ray integral to central venous catheter insertion)Report a problem with this question

  37. 37. A patient with two-vessel coronary disease undergoes on-pump coronary bypass through a median sternotomy. The surgeon takes down the left internal mammary artery as a pedicle and anastomoses it to the LAD, then takes down the right internal mammary artery and anastomoses it to the posterior descending artery. Both mammary grafts stay attached at their origins. A third possible target, a small diagonal branch, is inspected and judged too small to graft. No saphenous vein or radial artery is harvested. Available codes: 33511 CABG, venous grafts only, 2 grafts; 33533 CABG, arterial grafts, 1 graft; 33534 CABG, arterial grafts, 2 grafts; 33535 CABG, arterial grafts, 3 grafts. Which code should be reported?

    • A.33533
    • B.33511
    • C.33535
    • D.33534✓ Answer

    Both grafts are arteries, so this is arterial-only bypass, and NCCI says only one code from the 33533-33536 arterial range is reported, chosen by the number of arterial grafts actually placed. Two mammary grafts were placed, which is 33534. 33533 counts only the LAD graft. 33535 counts the diagonal branch that was inspected but never grafted. 33511 is in the venous-graft family, which does not apply because no vein was used and mammary arteries are arterial conduits. Taking down an in-situ mammary artery is part of the bypass, so there is no harvest add-on.

    Ref QB-PS9RS6Source: CMS NCCI Policy Manual for Medicare Services (rev. 1/1/2026), Ch. V §D.2 (when only arterial grafting is performed, only one code from 33533-33536 may be reported)Report a problem with this question

  38. 38. A patient with chronic diarrhea has a colonoscopy to the cecum with a good prep. Patchy erythema in the transverse colon is sampled with cold biopsy forceps at three sites, and all three samples go into one specimen jar. In the sigmoid colon, a separate 12 mm pedunculated polyp is removed with a hot snare. No other interventions are performed. Available codes: 45378 diagnostic colonoscopy; 45380 colonoscopy with single or multiple biopsies; 45384 colonoscopy with lesion removal by hot biopsy forceps; 45385 colonoscopy with lesion removal by snare technique. Which code(s) should be reported?

    • A.45385, 45378-59
    • B.45385, 45380-59✓ Answer
    • C.45384, 45380-59
    • D.45385, 45380-51

    The polyp was removed with a snare, so it is 45385 even though the snare carried current; 45384 is only for removal with hot biopsy forceps. The three biopsies are reported once with 45380, which covers single or multiple biopsies. Because they were taken from a different lesion than the polyp, NCCI allows the 45385/45380 edit to be bypassed with modifier 59 or XS. Modifier 51 does not bypass that edit, so 45385 with 45380-51 would be denied. 45378 is the diagnostic colonoscopy, which is included in any surgical colonoscopy and is never added to 45385.

    Ref QB-3A2KP2Source: CMS NCCI Policy Manual for Medicare Services (rev. 1/1/2026), Ch. VI §H.25 (the 45385/45380 PTP edit may be bypassed with modifier 59 or XS when the procedures are performed on separate lesions)Report a problem with this question

  39. 39. A 30-year-old with four days of abdominal pain is taken for a planned laparoscopic appendectomy. On entry, the surgeon finds a perforated appendix with purulent fluid in all four quadrants (generalized peritonitis) and dense inflammatory adhesions that prevent safe laparoscopic dissection. The procedure is converted to an open lower midline laparotomy, the appendix is removed, and the abdomen is irrigated and closed. Available codes: 44950 open appendectomy; 44960 open appendectomy for ruptured appendix with abscess or generalized peritonitis; 44970 laparoscopic appendectomy; 44979 unlisted laparoscopic procedure, appendix. Which code should the surgeon report?

    • A.44979
    • B.44960✓ Answer
    • C.44970
    • D.44950

    When a laparoscopic procedure is converted to open at the same encounter, NCCI says only the open procedure is reported, and neither the surgical nor the diagnostic laparoscopy is coded. The open removal was for a ruptured appendix with generalized peritonitis, which is 44960. 44950 is the open appendectomy without rupture and peritonitis, so it ignores the documented findings. 44970 reports the laparoscopic approach that was abandoned. 44979 is for a laparoscopic procedure that has no specific code, not for a case that ended as an open operation.

    Ref QB-KS7R93Source: CMS NCCI Policy Manual for Medicare Services (rev. 1/1/2026), Ch. VI §F.4 (if a laparoscopic procedure is converted to an open procedure, only the open procedure is reported)Report a problem with this question

  40. 40. For a Medicare claim: through an open lower midline incision, a surgeon performs a sigmoid colectomy for a diverticular stricture with a primary colorectal anastomosis. No stoma is created, and the splenic flexure is not mobilized. While the descending colon is being retracted, a retractor tears the splenic capsule; the bleeding cannot be controlled, so the surgeon performs a total splenectomy. The sigmoid mesentery, with its lymph nodes, is removed en bloc with the specimen. Available codes: 38100 total splenectomy; 38747 regional abdominal lymphadenectomy; 44140 partial colectomy with anastomosis; 44141 partial colectomy with skin-level cecostomy or colostomy. Which code(s) should the surgeon report?

    • A.44140 only✓ Answer
    • B.44140, 38747
    • C.44140, 38100
    • D.44141 only

    The planned procedure is a partial colectomy with a primary anastomosis, which is 44140. 44140 with 38100 fails because NCCI treats repair of an iatrogenic splenic laceration, with or without splenectomy, as a complication of the surgery that is not separately reportable, and it names colectomy and the splenectomy codes in that rule. 44140 with 38747 fails because the regional lymphadenectomy code is not reported for nodes removed in the operative field of a colectomy. 44141 is for a partial colectomy that ends with a skin-level cecostomy or colostomy, and no stoma was created.

    Ref QB-6XPZUGSource: CMS NCCI Policy Manual for Medicare Services (rev. 1/1/2026), Ch. V §E.3 (repair of iatrogenic splenic laceration, with or without splenectomy such as 38100, not separately reportable during colectomy) and §E.2 (38747 not reported for nodes in the operative field of a colectomy)Report a problem with this question

  41. 41. For a Medicare claim: a patient with symptomatic gallstones also has a reducible 4 cm incisional hernia in an old right subcostal scar. The surgeon performs an open cholecystectomy through that same scar; no intraoperative cholangiogram is done. At closure, the surgeon excises the hernia sac and repairs the fascial defect with onlay mesh. The documentation supports medical necessity for both the gallbladder removal and the hernia repair. Available codes: 47562 laparoscopic cholecystectomy; 47600 open cholecystectomy; 47605 open cholecystectomy with cholangiography; 49593 initial anterior abdominal hernia repair, total defect 3 to 10 cm, reducible. Which code(s) should be reported?

    • A.47605 only
    • B.47562 only
    • C.47600 only✓ Answer
    • D.47600, 49593

    The gallbladder was removed through an open incision without cholangiography, which is 47600. 47600 with 49593 fails because NCCI says a hernia repair at the site of the incision used for an open or laparoscopic abdominal procedure is not separately reportable, even when the hernia is real and the repair is medically necessary; the mesh is not coded separately either. 49593 could be reported only for a hernia at a different site from the incision. 47605 requires an intraoperative cholangiogram, which was not done. 47562 is the laparoscopic code, and this cholecystectomy was open.

    Ref QB-NEHU9GSource: CMS NCCI Policy Manual for Medicare Services (rev. 1/1/2026), Ch. VI §E.4 (hernia repair at the site of the incision for an open or laparoscopic abdominal procedure, e.g., 49591-49596, not separately reportable) and §E.7 (mesh implantation not reported with a hernia repair)Report a problem with this question

Other topics in this exam

Practice questions based on the ICD-10-CM Official Guidelines for Coding and Reporting, the AMA CPT guidelines, the CMS HCPCS Level II system, and federal healthcare compliance law. CPC is a mark of the AAPC and CPT is a mark of the American Medical Association; this site is not affiliated with or endorsed by either. ICD-10-CM, CPT, and HCPCS Level II are revised every year, so these questions test coding rules and conventions rather than code values — always verify actual code selection against the current code books and your payer's published policy. Nothing here is medical, legal, or billing advice. About the CPC exam →