Start practice test →1. During a Thomas test with the back and sacrum flat on the table, the back of a client's lowered thigh rests on the table, but the knee of that leg cannot bend to 80 degrees. Which muscle is most likely tight?
- A.Rectus femoris✓ Answer
- B.Iliopsoas
- C.Hamstrings
- D.Tensor fasciae latae
The rectus femoris crosses both the hip and the knee, so when it is short it holds the knee straighter even after the thigh reaches the table. A thigh that stays up while the knee bends to 80 degrees would point to the iliopsoas instead; the hamstrings and tensor fasciae latae do not stop knee flexion in this position.
Ref QB-SJWBF8Source: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Thomas Test interpretation tableReport a problem with this question
2. During a Thomas test with the back and sacrum flat, the back of a client's lowered thigh stays above the table, and the knee of that leg also cannot bend to 80 degrees. What does this pattern suggest?
- A.Tightness limited to the iliopsoas, with normal rectus femoris length
- B.Tightness in the primary hip flexors, both iliopsoas and rectus femoris✓ Answer
- C.Tightness in the hamstrings, with the pelvis pulled into posterior tilt
- D.Tightness limited to the rectus femoris, with normal iliopsoas length
A raised thigh points to a short iliopsoas, and a knee that cannot reach 80 degrees points to a short rectus femoris, so both findings together implicate the primary hip flexors as a group. Reading only one of the two findings misses half the picture, and tight hamstrings would not lift the thigh off the table in this test.
Ref QB-B3FU7ASource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Thomas Test interpretation tableReport a problem with this question
3. Use this standard: in the passive straight-leg raise, normal hamstring length means the raised leg reaches 80 degrees or more before the pelvis rotates posteriorly. A client's right leg reaches 65 degrees before her pelvis starts to tilt back, and her left leg reaches 85 degrees. How should the trainer record the result?
- A.Both sides tight using the lower score
- B.Right side tight and left side normal✓ Answer
- C.Left side tight and right side normal
- D.Both sides normal using the averaged score
Each leg is judged on its own against the 80-degree standard: the right leg stopped at 65 degrees, so the right hamstrings are short, while the left leg passed at 85 degrees. Averaging the two (75 degrees) or applying the worse side to both hides the left-right difference that the test is meant to reveal, and swapping the sides misreads which leg fell short.
Ref QB-TJ9PM9Source: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Passive Straight-leg (PSL) Raise interpretation tableReport a problem with this question
4. A new client with a history of low-back pain wants her hamstring flexibility checked at her first assessment. Which assessment choice fits best?
- A.Use the passive straight-leg raise, which spares the low back✓ Answer
- B.Use the sit-and-reach test, which is the most common field test
- C.Use a standing toe touch, which shows real-life flexibility
- D.Use the Thomas test, which measures hamstring length directly
The sit-and-reach and a standing toe touch both push the hip and spine to end-range flexion, which people with a history of low-back pain should avoid. The passive straight-leg raise isolates hamstring length with the back supported on a table or mat. The Thomas test measures hip flexor length, not the hamstrings.
Ref QB-C3T6DBSource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Sit-and-Reach Test limitations and Passive Straight-leg (PSL) RaiseReport a problem with this question
5. Viewed from the side, a client stands with the ASIS tilted upward and backward and a flattened lower back. Which muscles are most likely tight?
- A.Rectus abdominis and hamstrings✓ Answer
- B.Gluteus medius and hip adductors
- C.Pectoralis minor and upper trapezius
- D.Hip flexors and erector spinae
An ASIS tilted upward and backward is a posterior pelvic tilt. The rectus abdominis pulls the front of the pelvis up and the hamstrings pull the back of it down, so these are the suspected tight muscles, while the hip flexors and erector spinae are suspected to be lengthened. Tight hip flexors and erector spinae go with the opposite pattern, an anterior tilt.
Ref QB-UJMZSASource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Deviation 3: Pelvic Tilting tableReport a problem with this question
6. A trainer lines a client up sideways to a plumb line that hangs just in front of the outer anklebone. In ideal posture, which set of landmarks should the line pass through?
- A.Anterior third of knee, greater trochanter, AC joint, by the earlobe✓ Answer
- B.Front of the kneecap, front of the hip joint, mid-chest, tip of the nose
- C.Anterior third of the knee, the ASIS, middle of the scapula, the temple
- D.Back of the knee joint, greater trochanter, AC joint, front of the jaw
In the side view, good alignment places the body's segments evenly around the line of gravity: the line passes through the anterior third of the knee, the greater trochanter of the femur and the acromioclavicular joint, and runs slightly in front of the mastoid process, in line with or just behind the earlobe. Landmarks such as the ASIS, the kneecap or the nose sit off that line of gravity.
Ref QB-D36HJCSource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Plumb Line Positions: Sagittal ViewReport a problem with this question
7. During a static postural assessment, a client's arches flatten and her ankles roll inward. Following the kinetic chain upward, which related changes should the trainer look for next?
- A.Internal femoral rotation and a posterior pelvic tilt with a flatter low back
- B.External femoral rotation and a posterior pelvic tilt with a flatter low back
- C.External femoral rotation and an anterior pelvic tilt with more lumbar lordosis
- D.Internal femoral rotation and an anterior pelvic tilt with more lumbar lordosis✓ Answer
Foot pronation is coupled with internal rotation of the tibia and femur, and the pelvis may then tilt anteriorly to accommodate the femoral head, which increases lumbar lordosis. External rotation goes with supination, and a posterior tilt with a flat back is not the chain reaction that pronation produces.
Ref QB-VJYBYBSource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Deviation 1: Ankle Pronation/Supination and Deviation 3: Pelvic TiltingReport a problem with this question
8. Viewed from behind, the inferior angle and medial border of a client's shoulder blades stick out from her rib cage while she stands relaxed. What does this observation most likely indicate?
- A.Tight upper-back extensors, mainly the erector spinae and multifidus
- B.Weak scapular stabilizers, mainly the rhomboids and serratus anterior✓ Answer
- C.Weak rotator cuff muscles, mainly the supraspinatus and infraspinatus
- D.Tight scapular stabilizers, mainly the rhomboids and serratus anterior
Scapular winging means the scapular stabilizers, chiefly the rhomboids and serratus anterior, cannot hold the scapulae flat against the rib cage; the serratus anterior is usually lengthened, not tight, with winging. The rotator cuff controls the humeral head rather than holding the scapula to the ribs, and the spinal extensors do not anchor the scapula.
Ref QB-E3HUQDSource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Deviation 4: Scapular Winging and Scapular ProtractionReport a problem with this question
9. During the shoulder push stabilization screen, a client's shoulder blades stay flat against his rib cage, but his low back sags toward the floor on each push-up. What does this compensation most likely reflect?
- A.Weak triceps that cannot lock the elbows out at the top of each rep
- B.Weak serratus anterior that cannot hold the scapulae on the rib cage
- C.Lack of core, abdominal and low-back strength to stabilize the trunk✓ Answer
- D.Limited thoracic rotation that forces the lumbar spine to move
In this screen, hyperextension or collapsing of the low back points to a lack of core, abdominal and low-back strength, which leaves the trunk unstable. Weak serratus anterior would show up as scapular winging, which this client does not have, and thoracic rotation and triceps strength do not explain a sagging trunk.
Ref QB-WJBP5DSource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Shoulder Push Stabilization Screen tableReport a problem with this question
10. During the hurdle step screen viewed from the side, a trainer watches the client's moving leg as it lifts up toward the hurdle. Which quality is being checked on that leg?
- A.Hip mobility, with about 70 degrees of hip flexion and no anterior pelvic tilt✓ Answer
- B.Ankle stability, with a foot that stays flat and shows no inversion or eversion
- C.Hamstring length, with a straight knee held at 90 degrees of hip flexion
- D.Knee stability, with a knee that tracks straight over the second toe of the foot
The hurdle step screen checks stability of the stance leg and mobility of the stepping leg. In the side view, the trainer looks for about 70 degrees of hip flexion on the moving leg without compensating by tilting the pelvis forward. Foot and knee stability are judged on the stance leg, and the screen does not hold a straight knee to measure hamstring length.
Ref QB-MF8NX8Source: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Hurdle Step Screen observationsReport a problem with this question
11. Use this standard: in the seated thoracic spine mobility screen, trunk rotation of 45 degrees in each direction shows no compensation. A client rotates 45 degrees to the right but only about 30 degrees to the left, and her low back arches as she pushes for more. How should the trainer read this?
- A.Limited left thoracic rotation with lumbar compensation✓ Answer
- B.Limited lumbar rotation that needs lumbar mobility work
- C.Limited right thoracic rotation with lumbar compensation
- D.Normal thoracic rotation on both sides of the trunk
The left side falls short of the 45-degree standard, so left thoracic rotation is limited. The lumbar spine offers only about 15 degrees of rotation, so when the thoracic spine is stiff the body borrows movement from the low back, for example by increasing lordosis. The lumbar spine is meant to stay stable, so adding lumbar mobility work would be the wrong fix.
Ref QB-5YDTH9Source: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Thoracic Spine Mobility ScreenReport a problem with this question
12. A trainer is setting up the sharpened Romberg test for a client. Which setup matches the protocol?
- A.Shoes on, feet side by side, hands resting on the hips, eyes kept open
- B.Shoes off, heel-to-toe stance, arms folded across the chest, eyes closed✓ Answer
- C.Shoes off, one foot raised to the other knee, heel lifted, eyes closed
- D.Shoes on, both feet on a foam pad, arms at the sides, eyes closed
The sharpened Romberg test narrows the base of support and removes vision: the client stands barefoot heel-to-toe in tandem, folds the arms so each hand touches the opposite shoulder, then closes the eyes once stable, for up to 60 seconds. Raising one foot to the knee with the heel up is the stork-stand test, and a foam pad or open eyes changes what is being tested.
Ref QB-NFKY4ASource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Sharpened Romberg TestReport a problem with this question
13. A client is doing the stork-stand balance test on the ball of her right foot, with her eyes open, her hands on her hips and her left foot resting against the inside of her right leg just below the knee. Which event should stop the timer?
- A.Her body sways slightly and then recovers
- B.Her breathing becomes noticeably faster
- C.Her left foot presses harder into the knee
- D.Her right heel comes down to the floor✓ Answer
Timing stops when the stance heel touches the floor, the hands leave the hips, the stance foot moves in any direction, the raised foot loses contact with the stance leg, or the client loses balance. A brief sway that she recovers from, faster breathing, or pressing the raised foot more firmly against the knee does not meet any of those stop conditions.
Ref QB-6YR5QASource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Stork-stand Balance Test observationsReport a problem with this question
14. On Apley's scratch test, a client touches the target landmarks easily with her right arm, but her left arm falls well short when it reaches up behind her back. What should the trainer do next?
- A.Score both shoulders as good mobility based on the right arm's result
- B.Record a likely left rotator cuff tear and remove all overhead work for now
- C.Repeat the scratch test several times until the left hand reaches the mark
- D.Test shoulder flexion-extension and rotation separately to find the source✓ Answer
Apley's scratch test combines several shoulder movements in all three planes at once, so a missed landmark or a left-right difference calls for further evaluation of the individual movements, such as shoulder flexion and extension and internal and external rotation of the humerus, to find which one is limited. Naming an injury is outside a trainer's scope, repeating the test does not locate the limit, and the stronger side cannot stand in for the weaker one.
Ref QB-PFXAABSource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Apley's Scratch Test interpretation tableReport a problem with this question
15. Use this criterion: a trunk flexion to extension endurance ratio below 1.0 indicates balance. A client holds the trunk flexor endurance test for 132 seconds and the trunk extensor (Biering-Sorensen) test for 110 seconds. What is the flexion:extension ratio, and what does it show?
- A.0.83, flexor and extensor endurance are balanced
- B.0.83, flexor endurance lags behind extensor endurance
- C.1.20, extensor endurance lags behind flexor endurance✓ Answer
- D.1.20, flexor and extensor endurance are balanced
Flexion:extension = 132 ÷ 110 = 1.20, which is above the 1.0 target, so the extensors are relatively weak compared with the flexors. 0.83 comes from dividing in the wrong order (110 ÷ 132); calling 1.20 balanced misreads the cutoff, and saying the flexors lag uses the inverted ratio.
Ref QB-7Y4GVBSource: McGill's Torso Muscular Endurance Test Battery protocol (American Council on Exercise, acefitness.org ACE Answers forms), ratios section, https://www.acefitness.org/images/webcontent/assets/certification/ace-answers/forms/pt/19_Mcgills_Torso_Muscular_Endurance_Test_Battery_Protocol.pdfReport a problem with this question
16. Use this criterion: the right-side bridge to left-side bridge ratio should be within 0.05 of a balanced score of 1.0. A client holds the right side bridge for 72 seconds and the left side bridge for 90 seconds. What is the right:left ratio, and is it balanced?
- A.1.25, inside the balanced range
- B.0.80, inside the balanced range
- C.0.80, outside the balanced range✓ Answer
- D.1.25, outside the balanced range
Right:left = 72 ÷ 90 = 0.80. The balanced band is 0.95 to 1.05, so 0.80 falls outside it and the right side is relatively weak. 1.25 comes from dividing left by right, and either value called balanced misreads how narrow the 0.05 band is.
Ref QB-QFANFCSource: McGill's Torso Muscular Endurance Test Battery protocol (American Council on Exercise, acefitness.org ACE Answers forms), ratios section, https://www.acefitness.org/images/webcontent/assets/certification/ace-answers/forms/pt/19_Mcgills_Torso_Muscular_Endurance_Test_Battery_Protocol.pdfReport a problem with this question
17. Use this criterion: each side bridge to extension ratio should be below 0.75. A client holds the trunk extensor test for 120 seconds, the right side bridge for 84 seconds and the left side bridge for 96 seconds. What do the ratios show?
- A.Right 0.70 and left 0.80; both meet the target
- B.Right 0.70 meets the target; left 0.80 does not✓ Answer
- C.Right 0.70 misses the target; left 0.80 meets it
- D.Right 1.43 and left 1.25; neither meets the target
Right: 84 ÷ 120 = 0.70, which is below 0.75 and meets the target. Left: 96 ÷ 120 = 0.80, which is above 0.75, so the left lateral muscles are relatively strong compared with the extensors. 1.43 and 1.25 come from dividing extension by side bridge; calling both acceptable ignores the left result, and reversing which side passes treats the cutoff as a minimum.
Ref QB-8YFT2DSource: McGill's Torso Muscular Endurance Test Battery protocol (American Council on Exercise, acefitness.org ACE Answers forms), ratios section, https://www.acefitness.org/images/webcontent/assets/certification/ace-answers/forms/pt/19_Mcgills_Torso_Muscular_Endurance_Test_Battery_Protocol.pdfReport a problem with this question
18. A client has just finished the 3 minutes of stepping in a YMCA submaximal step test. What should the trainer do to obtain the recovery heart rate?
- A.Have the client walk slowly for 1 minute, then count the pulse for 15 seconds
- B.Have the client stand still on the step and count the pulse for 30 seconds
- C.Have the client lie down for 2 minutes, then count the pulse for one full minute
- D.Have the client sit down at once and count the pulse for one full minute✓ Answer
The score is the heart rate counted for one entire minute starting immediately after stepping stops, with the client seated and quiet, because the post-exercise heart rate keeps falling across that minute and the norms are built on that full count. Walking, a delay before counting, or a shorter count changes the value and makes it incomparable with the norms.
Ref QB-RFNYMDSource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), YMCA Submaximal Step Test protocolReport a problem with this question
19. A trainer plans a YMCA submaximal step test for a 45-year-old client, who then mentions recurring knee problems and some trouble keeping her balance on stairs. What is the best decision?
- A.Keep the step test but let her pick a slower cadence of her own
- B.Keep the step test and let her hold the trainer's hand throughout
- C.Choose another cardiorespiratory test that suits her knees and balance✓ Answer
- D.Skip cardio testing and base her plan on age-predicted norms instead
Step testing may not be appropriate for people with orthopedic problems such as knee trouble or with balance concerns, so the trainer should pick a different cardiorespiratory assessment that fits her. Changing the cadence or holding on breaks the standardized protocol the norms depend on, and skipping testing altogether throws away a useful baseline when a suitable test exists.
Ref QB-9YT58ESource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), YMCA Submaximal Step Test contraindicationsReport a problem with this question
20. During a push-up test, a client's hips begin to sag and he cannot hold a rigid trunk for two repetitions in a row, although he says he can keep going. What should the trainer do?
- A.Let him go on to fatigue and count every repetition he completes
- B.Pause the test for 30 seconds, then let him finish more repetitions
- C.Switch him to modified push-ups and add those to his total count
- D.End the test and record the repetitions done with proper technique✓ Answer
The push-up test ends when the client cannot complete a repetition or fails to keep proper technique for two consecutive repetitions, so the trainer stops it and scores the repetitions done correctly. Counting sagging repetitions, resting mid-test, or mixing in modified push-ups breaks the protocol and makes the score impossible to compare with norms or with a later retest.
Ref QB-WN85HKSource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Push-up Test protocolReport a problem with this question
21. During a postural assessment, a client's spine curves visibly to one side, and she mentions ongoing back pain that spreads into her hip. What should the trainer do?
- A.Tell her the curve is scoliosis and design a program to straighten it
- B.Start corrective stretches on the shorter side and recheck in a month
- C.Refer her to a qualified healthcare professional and note the finding✓ Answer
- D.Massage the tight side of her back before each session to ease pain
Postural assessment stays within scope only when trainers recognize that pain or an underlying pathology such as scoliosis calls for referral to a more qualified healthcare professional. Naming the condition, treating it with targeted stretches, or massaging the painful area all cross into diagnosis or treatment, which a trainer does not provide.
Ref QB-D63YWJSource: ACE Group Fitness Instructor Fitness Assessment Protocols (American Council on Exercise, acefitness.org GFI_Assessments.pdf), Static Postural Assessment: scope of practice and referralReport a problem with this question
22. Use this criterion for stopping a submaximal cycle test: systolic blood pressure above 250 mm Hg or diastolic above 115 mm Hg. At the fourth stage, a client's blood pressure reads 256/88 mm Hg, and he says he feels fine. What should the trainer do?
- A.Lower the workload by one stage and continue the test from that point
- B.Stop the test and have him cool down while you keep monitoring him✓ Answer
- C.Hold the current stage for two more minutes, then decide what to do
- D.Continue the test to the final stage while rechecking his blood pressure
Either value crossing its limit is enough to end the test: the systolic reading of 256 mm Hg exceeds 250 even though the diastolic is normal and the client feels fine. Stopping, then having him cool down under continued monitoring, follows the termination criterion; continuing, holding the stage or merely lowering the load keeps him exercising past a stop signal.
Ref QB-XNKFPMSource: ASNC Practice Point: Exercise Stress Testing (American Society of Nuclear Cardiology), indications for terminating exercise testing: hypertensive response (systolic BP >250 mm Hg and/or diastolic >115 mm Hg)Report a problem with this question
23. During intake, a client's averaged seated resting blood pressure is 132/76 mm Hg. Using the ACC/AHA adult blood pressure categories, how should the trainer classify this reading?
- A.Normal blood pressure
- B.Elevated blood pressure
- C.Stage 1 hypertension✓ Answer
- D.Stage 2 hypertension
Stage 1 hypertension begins at a systolic pressure of 130 mm Hg or a diastolic pressure of 80 mm Hg (below 140/90), and only one of the two numbers has to reach the range. The systolic value of 132 qualifies even though the diastolic value of 76 is normal. 'Elevated' applies only when systolic is 120 to 129 with diastolic under 80, and Stage 2 starts at 140/90. The trainer records the category and refers the client to a physician rather than diagnosing.
Ref QB-E6EA4MSource: MedlinePlus Medical Encyclopedia, 'Blood pressure measurement' (NLM, updated 07/01/2025), What Abnormal Results Mean: elevated = systolic 120-129 with diastolic <80; Stage 1 = 130/80 or higher but lower than 140/90 (per 2017 ACC/AHA guideline); ACE Industry Guidelines page names the ACC/AHA guideline as the reference for categorizing adult BPReport a problem with this question
24. While slowly deflating a cuff that was pumped to 150 mm Hg, a trainer first hears tapping at 128 mm Hg, hears the sounds turn muffled at 90 mm Hg, and hears them stop completely at 82 mm Hg. What resting blood pressure should be recorded?
- A.128/90 mm Hg
- B.128/82 mm Hg✓ Answer
- C.150/82 mm Hg
- D.150/90 mm Hg
Systolic pressure is the cuff pressure at which the pulsing sound is first heard (128), because that is when blood first forces its way past the cuff. Diastolic pressure is the point at which the sounds stop (82), not the earlier point where they only become muffled. The 150 mm Hg inflation level is just a starting pressure set above systolic, so it is never recorded as a reading.
Ref QB-YNXSUNSource: MedlinePlus Medical Encyclopedia, 'Blood pressure measurement' (NLM), How the Test is Performed: reading when the pulsing sound is first heard = systolic; point at which the sound stops = diastolicReport a problem with this question
25. A competitive bodybuilder has a BMI of 29 and a small waist. He asks whether this means he is overweight. What is the most appropriate way for the trainer to assess his body composition?
- A.Classify him as overweight from his BMI alone
- B.Track his BMI weekly to monitor his fat loss
- C.Use his waist-to-hip ratio to estimate body fat
- D.Estimate his body fat with skinfold measurements✓ Answer
BMI compares weight with height and cannot tell fat mass from lean mass, so heavily muscled clients often read as overweight or obese. ACE advises against using BMI as the only measure for athletic builds and names a skinfold estimate of body fat as the more accurate choice. Tracking BMI repeats the same flaw, and the waist-to-hip ratio shows where fat is stored, not what percentage of the body is fat.
Ref QB-F6SM9NSource: ACE Exam Preparation Blog, 'What Is Body Mass Index (BMI) & Can I Rely on It?' (acefitness.org, blog 2839): BMI uses body weight, not percent fat; not recommended as the only measure for muscular/athletic builds; skinfold estimate is more accurateReport a problem with this question
26. A new client with obesity wants to track progress toward weight loss but says she feels self-conscious about being measured. Which baseline measure is most appropriate for her?
- A.Circumference (girth) measurements✓ Answer
- B.Three-site skinfold measurements
- C.Seven-site skinfold measurements
- D.Hydrostatic (underwater) weighing
ACE notes that many body-composition methods are not accurate in people with obesity, so body-size measures are generally the better choice for this group. Girth measurements are less invasive than skinfolds, which matters for a self-conscious client, and they show progress in inches lost that stays motivating even while her body-fat category has not yet changed. Skinfolds at any number of sites are hard to obtain accurately in obesity, and hydrostatic weighing is a costly lab method.
Ref QB-ZNA52QSource: ACE Exam Preparation Blog, 'Anthropometric Measurements: When to Use this Assessment' (acefitness.org, blog 3815): many body-composition methods are not accurate for individuals who are obese, so body-size measurements are generally best; girth is less invasive than skinfolds; ACE Answers FAQ case study (skinfold may not be appropriate for a client 40 lb overweight; use BMI and girth)Report a problem with this question
27. A trainer is recording a 3-site skinfold assessment for a female client on ACE's Anthropometric Measurements Form. Which three sites belong in her column?
- A.Chest, abdomen, and thigh
- B.Triceps, abdomen, and thigh
- C.Triceps, suprailium, and thigh✓ Answer
- D.Chest, suprailium, and thigh
The 3-site skinfold method uses different sites for each sex because men and women store subcutaneous fat in different patterns. ACE's form lists triceps, suprailium and thigh for women, and chest, abdomen and thigh for men. Thigh is the only site the two sets share, so mixing chest or abdomen into a woman's sum puts her total on the wrong prediction equation.
Ref QB-G65YEPSource: ACE Anthropometric Measurements Form (acefitness.org ACE Answers forms/pt/46_Anthropometric_Measurements_Form.pdf), Skinfold Measurements section: Men = chest, abdomen, thigh; Women = triceps, suprailium, thighReport a problem with this question
28. After rotating through the measurement sites, a trainer takes two waist circumference readings of 86.0 cm and 86.8 cm. According to ACE's circumference measurement protocol, what should the trainer do?
- A.Record the average, since the readings are within 1 cm
- B.Remeasure, since the readings are more than 5 mm apart✓ Answer
- C.Record the lower value, since the tape was likely loose
- D.Keep the first value, since later readings drift upward
ACE's protocol calls for duplicate measurements at each site and requires a remeasure whenever the values are not within 5 mm; these differ by 8 mm. The trainer should also wait 20 to 30 seconds between measurements so the skin and underlying tissue return to their normal position. Averaging, keeping the lower value or keeping the first value would all lock an unreliable number into the baseline used to track progress.
Ref QB-SNTSTESource: ACE Circumference Measurements Protocol (acefitness.org ACE Answers forms/pt/45_Circumference_Measurements_Protocol.pdf): rotate through sites; duplicate measurements at each site; if values are not within 5 mm, remeasure; wait 20-30 seconds between measurementsReport a problem with this question
Other topics in this exam
Practice questions written to the published ACE Personal Trainer Exam Content Outline and to standard exercise-science material. ACE is a mark of the American Council on Exercise; this site is not affiliated with or endorsed by it. Exam content outlines are revised after each role delineation study, so confirm current requirements with ACE before testing. Nothing here is medical advice; a personal trainer does not diagnose, treat, or prescribe. ACE exam content outline →